Figure 2

Sit and Honeywell Millivolt Gas Valve 

Showing Piezo Igniter Location (Each Unit is 

Equipped with Only One of these Gas Valves) 

       WARNING 

These fireplaces are vented 
heaters.  Do not burn wood or 
other material in these appli-
ances.

       WARNING 

This appliance is only for use 
with the type of gas indicated on 
the rating plate. This appliance 
is not convertible for use with 
other gases, unless a certifi ed 
kit is used.

       WARNING 

Do not place clothing or other 
fl ammable materials on or near 
this appliance.

       WARNING 

Carbon monoxide poisoning: 
early signs of carbon monoxide 
poisoning are similar to the fl u 
with headaches, dizziness and/or 
nausea. If you have these signs, 
obtain fresh air immediately. Turn 
off the gas supply to the appliance 
and have it serviced by a quali-
fi ed professional, as it may not 
be operating correctly.

       WARNING 

Any safety guard or screen 
removed for servicing the appli-
ance must be replaced prior to 
operating the appliance.

       WARNING 

Children and adults should be 
alerted to the hazards of high 
surface temperatures. Use cau-
tion around the appliance to 
avoid burns or clothing ignition. 
Young children should be carefully 
supervised when they are in the 
same room as the appliance.

Note: An Optional Screen Heat 
Guard for the glass is available 
(see Page 16 for ordering infor-
mation).

Gas Controls/Control Compartment 
Access

The gas controls can be found behind the control 
compartment access door. 

Removing Control Compartment Door:

Open the door by  gently liftint it upward until the 
hook catches on boths sides clear the locating 
slots. Then pull door out to remove.

On millivolt systems, the piezo igniter, HI/LO 
fl ame adjustment knob, and pilot and main 
gas OFF/ON control knob are located below 
the glass panel enclosure. The gas valve for 
electronic systems is also located below the 
glass enclosure panel. See 

Figure 1.

Reinstalling Control Compartment Door:

To reinstall, insert the hook catches on each 
side of the door into the corresponding slots 
in the control compartment opening, then 
gently push forward and slide down until it 
locks in place.

Figure 1 

OPENING CONTROL
COMPARTMENT DOOR

Operation of millivolt and electronic gas con-
trol systems are different. Before lighting and 
operating your appliance determine if you have 
a millivolt or electronic appliance. Familiarize 
yourself with the gas control valve that your 
appliance uses. Refer to 

Figure 1 

for access 

to the gas control valve.

 

Millivolt Appliances 

-  Appliances with 

Millivolt systems will be fi tted with the gas 
control valve shown in 

Figures 4 or 5. 

 

Electronic Appliances

 - Appliances with 

electronic systems will be fi tted with the 
electronic valve shown in 

Figure 3. 

Millivolt Appliances - 

To light millivolt appli-

ances refer to the detailed lighting instructions 
found on 

Page 17 

Millivolt appliance lighting 

instructions may also be found on the pull out 
lighting instruction labels attached to the gas 
control valve

.

Millivolt appliances are fi tted  with  an  OFF/ON 
Rocker Switch located behind the control 
compartment access door, below the appli-
ance front glass enclosure panel (see 

Figure 2 

for location).  Once the pilot is lit, the OFF/ON 
rocker switch will control the appliance OFF/ON 
burner operation.  To operate:  Toggle the switch 
between its ON and OFF positions.

If your millivolt appliance is equipped with an 
optional remote switch kit (wall switch, remote 
control or wall thermostat) and the pilot is lit, 
the appliance main burner may be turned on 
and off using the optional switch. When using 
an optional remote switch, turn off the standard 
OFF/ON switch.

OPERATION AND CARE OF YOUR 
APPLIANCE

The standard controls for appliance operation 
are located behind the hinged drop-down panel 
below the appliance front glass enclosure panel 
(see 

Figure 1).

  Optional control switches are 

also available (see 

Page 14 

Remote Wall 

Switch, Remote Control or Wall Thermostat

). 

Note:

 To prevent excessive resistance in burner 

circuit (which can cause burner operation prob-
lems), only one burner control switch should be 
wired to valve. Therefore, if an optional control 
switch is installed, the standard Off/On switch 
and wires should be removed.

Control Valve

Lower Control 
Compartment Door

SIT Gas Valve

Shown with control 
compartment door 
removed

Piezo Igniter

Honeywell
Gas Valve

Lift the Lower Control 
Compartment Door 
up and pull out to 
remove.

Up

Out

Hook Catch

Содержание DIRECT VENT MERIT LMDV-33 SERIES

Страница 1: ...O NOT light any appliance DO NOT touch any electrical switches Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow your gas suppliers instructions I...

Страница 2: ...ns Millivolt Page 17 Lighting Instructions Electronic Page 18 Maintenance Schedule Page 19 Troubleshooting Guide Millivolt Page 20 Troubleshooting Guide Electronic Page 20 Replacement Parts List Page...

Страница 3: ...nents Any modification or alteration may void the warranty certification and listings of this unit Theseappliancesandtheirindividualshut off valves must be disconnected from the gas supply piping syst...

Страница 4: ...down until it locks in place Figure 1 OPENING CONTROL COMPARTMENT DOOR Operation of millivolt and electronic gas con trol systems are different Before lighting and operatingyourappliancedetermineifyou...

Страница 5: ...ons Electronic appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve 3 Keep the lower control compartment clean by vacuuming o...

Страница 6: ...ed replacement use only the proper replacement logs from manufacturer see Pages 22 23 for ordering information Re Install Embers Logs and Vermiculite Carefully follow placement instructions on Pages 8...

Страница 7: ...front of the appliance 4 Swing the bottom of the door out and raise it slightly to lift the top flange of the door frame away from the appliance Installing Glass Enclosure Panels see Figure 6 1 Visua...

Страница 8: ...re 8 Logs should be placed in the order shown and per the following instructions WARNING DONOTattempttoinstallthelogs until the appliance installation hasbeencompleted thegasline connected and tested...

Страница 9: ...VolcanicStoneandLogsintheorder shown here 1 through 6 and per the instructions onPage8 A E B C D Vermiculite Volcanic Stone Embers DO NOT PLACE EMBERS OVER GAS SLOTS 1 2 3 4 5 6 The2notchesonlogbottom...

Страница 10: ...rrespond to photos InstalltheEmbers Vermiculite VolcanicStoneandLogsintheorder shownhere 1through6 andper theinstructionsonPage8 D C E A B 1 2 3 4 5 6 Vermiculite Volcanic Stone DONOTPLACEEMBERSOVERGA...

Страница 11: ...hanorangebodythatdoes not soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines If there is smoke or soot present first check the log set positioning t...

Страница 12: ...position until the proper flame appearance is achieved 4 Leave the control knob off pilot on in the ON position and the burner OFF ON switch OFF remote switches if applicable 5 When satisfied that the...

Страница 13: ...ctlytothe appliance on a pullout panel located within the control compartment TH TP TH TP Thermopile If any of the original wire as supplied must be replaced it must be replaced with Type AWM 105o C 1...

Страница 14: ...d system may be operated with electronic and mil livoltsystemswitheithernaturalgasorpropanegas The RCL T comes complete with detailed operating instructions Remote Control Kit Deluxe Cat No Model No D...

Страница 15: ...Doors Charcoal LMDV 4035 H0967 SPD40TI 40 Sq Pane Doors Textured Iron H0968 SPD40SP 40 Sq Pane Doors Satin Pewter H0969 SPD40AB 40 Sq Pane Doors Antique Brass Arch Design Arch Pane Design Square Desi...

Страница 16: ...nce These kits can be retrofitted to previously installed appliances ref Form 750 166M Polished Brass Brushed Stainless Hood Kits Attractive hoods are available in two styles These hoods are designed...

Страница 17: ...your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a qualified service technician Force or attempted repair ma...

Страница 18: ...been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCT...

Страница 19: ...o many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service...

Страница 20: ...witch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or remote control A Wall switch or wires defective Check wall switch and wi...

Страница 21: ...ommon leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identify proper lead this check must be done with the valve control con nected and igniter powered NO Check t...

Страница 22: ...93L32 1 Lennox Nameplate Logo 12L15 is sold separately Gas Controls SIT Millivolt Natural Gas Propane Gas Part No Qty Part No Qty 12 Gas Valve SIT 43K07 1 88J53 1 13 Piezo Igniter 111061 1 111061 1 14...

Страница 23: ...23 NOTE DIAGRAMS ILLUSTRATIONSNOTTOSCALE REPLACEMENT PARTS 7 8 1 2 9 10 13 12 6 19 11 3 5 15 18 16 14 17 4 24 25 26 27 23 22 30 29 32 28 20 31 21 8 LMDV 4035 LMDVT 3328 LMDVR 3530...

Страница 24: ...P N 875 028M REV C 06 2005 LENNOX reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult you...

Отзывы: