background image

18

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

LENNOX HEARTH PRODUCTS  •  MONTEBELLO

® 

 POWER VENT DV GAS FIREPLACES  (LSM40/45EN-PV)  •  CARE AND OPERATION INSTRUCTIONS

ACCESSORY COMPONENTS CONTINUED

Brick Liner Kits

The brick panel liner kits include ceramic panels 

of the side and rear walls.  The panels have 

brick-like features in relief.

Brick Liner Kits

LSM40-PV

H2219 BLKR-LSM40

Buff Rustic

H4801 BLK-REDR-LSM40 Red Rustic
H2220 BLKH-LSM40

Buff Herringbone

H4803 BLK-REDH-LSM40 Red Herringbone
H2221 BLKC-LSM40

Red Old Cottage

H2222 BLKB-LSM40

Black

LSM45-PV

H2223

BLKR-LSM45

Buff Rustic

H2224

BLKH-LSM45

Buff Herringbone

H2225

BLKC-LSM45

Red Old Cottage

H2226

BLKB-LSM45

Black

H4802 BLK-REDR-LSM45 Red Rustic
H4804 BLK-REDH-LSM45 Red Herringbone

Birch Logs

Rustic Oak

Log Sets

Choose from two finely crafted log sets with 

detailing    that  replicates  the  natural  look  of 

real wood.

Log Sets

Cat. No.

Model

Description

LSM40-PV and LSM45-PV

H4799

LOG-OAK-LSM-2

Oak Log Set

H4800

LOG-BIR-LSM-2

Birch Log Set

(ref. Kit Instruction P/N 750182M)

Andiron Door Kits

The andiron kits attach to the grate assembly 

without the use of hardware. 

CLASSIC

MISSION

Andiron Door Kits

Fits Fireplace 

Models

Catalog No. (Model)

Mission

Classic

LSM40-PV & 

LSM45-PV

H2227

(AKM-LSM)

H2228

(AKC-LSM)

(ref. Kit Instruction P/N 750,183M)

Classic Screen Kits 

These Screen kits can be installed on the glass 

enclosure panel to help prevent direct human 

contact with the hot glass surface. 

Arch Screen Kits

These Arch Screen kits can be installed on the 

glass  enclosure  panel  to  help  prevent  direct 

human contact with the hot glass surface. 

Dual Arch Screen Kits

These Dual Arch screen kits can be installed 

on the glass enclosure panel to help prevent 

direct human contact with the hot glass surface. 

Barrier Screen Kits 

These Barrier Screen Panel kits can be installed 

on the glass enclosure panel to help prevent 

direct human contact with the hot glass surface. 

Dual Arch Screen Kits

Cat. #

Model

Description

H5051 DASK-LSM40-2 Dual Arch Screen
H5054 DASK-LSM45-2 Dual Arch Screen

Classic Screen Kits

Cat. No.

Model

Description

H5052

SK-LSM40-2 Classic Screen Kit

H5055

SK-LSM45-2 Classic Screen Kit

Arch Screen Kits

Cat. No.

Model

Description

H5053

ASK-LSM40-2 Arch Screen Kit

H5056

ASK-LSM45-2 Arch Screen Kit

Barrier Screen Kits

Cat. No.

Model

Description

LSM40-PV

H4805

BSK40

Barrier Screen

LSM45-PV

H4806

BSK45

Barrier Screen

(ref. Kit Instruction P/N 750,184M)

(ref. Kit Instruction P/N 750,184M)

(ref. Kit Instruction P/N 750,184M)

(ref. Kit Instruction P/N 750,184M)

Содержание Dave Lennox Signature Montebello LSM40EN-PV

Страница 1: ...th WARNING AVERTISSEMENT AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS UNE SURFACE VITR E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROIDIR LA SU...

Страница 2: ...ce Operation Notices 6 Warranty Information 6 General Information 7 BTU Input 7 Gas Pressure Requirements 7 Orifice Sizes 7 Burn In Period 7 Operation and Care of Your Appliance 8 Appliance Operation...

Страница 3: ...ures lev es voir Page 5 Lisez la section Informations importantes relatives la s curit Page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla...

Страница 4: ...eil Les tout petits les jeunes enfants ou les adultes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes ri...

Страница 5: ...anera 1 Identifique el interruptor o el termostato de pared quecontrolalachimenea verifiquequeelinterruptor opera la chimenea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode...

Страница 6: ...nd to replace any part of the control system and any gas control that has been under water Thesefireplacesaredesignedassupple mentalheaters Therefore itisadvisable to have an alternate primary heat so...

Страница 7: ...nually modulated gas valve flame appear ance and heat output can be controlled at the gas valve The BTU Input for these appliances is shown in Table 1 Gas Pressure Requirements All Models Tables 2 and...

Страница 8: ...tches are also available see Page 15 remote wall switch remote control or wall thermostat Right Side Modesty Panel Access Plate Hi Lo Extension Knob ON OFF Switch Gas Valve WARNING Young children shou...

Страница 9: ...ch for appliance ON OFF control See Figure 1 for its location Once the pilot is lighted the ON OFF rocker switch will control the appliance ON OFF operation To operate Toggle the switch between its ON...

Страница 10: ...hree times during each heating season depending on the circumstances present The following cleaning solutions are approved for use to clean glass Non ammonia based household cleaner 50 50 mix of white...

Страница 11: ...lass Door Assembly WARNING When reinstalling the glass door the door latch screws must be securely tightened to prevent the glass door from falling out which could potentially cause damage and possibl...

Страница 12: ...ositioned properly as shown twigs will be positioned between flame peaks and will not impinge any flames Positioning is the same for all colors of log sets Figure 5 Figure 6 Glowing Embers Rockwool Fo...

Страница 13: ...rner Engage Logs 3 4 With The Grate Pins And Align Groves At The Bottom Of The Logs Over The Grate 4 3 Engage Log 6 With The Grate Pin And Align Groove At The Bottom Of The Log Over The Grate Align Ho...

Страница 14: ...shutter opening To achieve a warm yellowish orange flame with an orange body that does not soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines If the...

Страница 15: ...ratetheapplianceforaperiodoftimeasthe effect diminishes ensuring that the appliance does not develop sooty flames When satisfied that the appliance operates properly proceedtofinishtheinstallation Lea...

Страница 16: ...e installation or ap plication of this system please contact your dealer or distributor LENNOX HEARTH PRODUCTS 1508 Elm Hill Pike Suite 108 Nashville TN 37210 visit us at www Lennox com 1 800 9 LENNOX...

Страница 17: ...nds to the fireplace effortlessly with one simple motion TheModelRCLcomescompletewithdetailedoperat ing instructions Deluxe Remote Control System The Model RCL STAT Deluxe Remote Control System has al...

Страница 18: ...Kits Fits Fireplace Models Catalog No Model Mission Classic LSM40 PV LSM45 PV H2227 AKM LSM H2228 AKC LSM ref Kit Instruction P N 750 183M Classic Screen Kits These Screen kits can be installed on th...

Страница 19: ...Instructions Electronic 1 For complete shut down turn remote wall switch to OFF or set the thermostat to the lowest setting if applicable 2 Turn the ON OFF switch to OFF if Step 1 is not applicable 3...

Страница 20: ...ions de s curit sur la portion sup rieure gauche de cette tiquette 2 Tournez l interrupteur mural la position d arr t OFF ou plaez le thermostat plssible si requis 3 Tournezl interrupteur marche arr t...

Страница 21: ...the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the appropriate applian...

Страница 22: ...to valve Ensure blue and white 2 wires connection is secure to valve D Air in the gas line Purge gas line of air E Low voltage Test voltage at AC terminals of module for 24 VAC If no voltage replace...

Страница 23: ...t Is There Water Dirt In The Hose From The Blower To The Pressure Switch Are the Hose Connections Loose Is The Hose Cracked Replace Pressure Switch Replace Control Module Yes Yes Is The Lead To The Sp...

Страница 24: ...Left Side H3373 1 H3374 1 22 Floor Panel H3369 1 H3370 1 23 Bag of Volcanic Stone lava rock 80L42 1 80L42 2 24 Barrier Screen Panel H4805 1 H4806 1 25 Adaptor w Probe H7925 H7925 Contact an Authorize...

Страница 25: ...NNOX HEARTH PRODUCTS MONTEBELLO POWER VENT DV GAS FIREPLACES LSM40 45EN PV CARE AND OPERATION INSTRUCTIONS Replacement Parts ILLUSTRATIONS 25 40 42 16 7 18 8 6 5 9 17 12 4 14 13 HI LO 11 10 22 21 20 1...

Страница 26: ...7 H7384 Insulated 1 4 Male Terminal 4 8 H7371 Hose Clamp 11 32 2 15 H7372 Base Assembly Power Vent 1 16 H7378 Kicker Assembly 1 POWER VENT REPLACEMENT PARTS AND ILLUSTRATIONS Item Part Number Descript...

Страница 27: ...27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE LENNOX HEARTH PRODUCTS MONTEBELLO POWER VENT DV GAS FIREPLACES LSM40 45EN PV CARE AND OPERATION INSTRUCTIONS NOTES...

Страница 28: ...Elm Hill Pike Suite 108 Nashville TN 37210 Printed in U S A 2009 Lennox Hearth Products P N 506025 02 Rev C 06 2011 Lennox Hearth Products reserves the right to make changes at any time without notic...

Отзывы: