Figure 14 - Burner Flame Appearance

(Rustic Oak Logs Shown) LSM45-PV

Figure 13 - Burner Flame Appearance

(Birch Logs Shown) LSM40-PV

BURNER ADjUSTMENTS 

(QUALIFIED TECHNICIANS ONLY)

Flame Appearance and Sooting 

Proper flame appearance is a flame which is 

blue at the base and becomes yellowish-orange 

in the body of the flame.  When the appliance 

is first lit, the entire flame may be blue and will 

gradually turn yellowish-orange during the first 

15 minutes of operation. After 15 minutes of 

operation, if the flame is blue, or if the flame is 

orange with evidence of sooting (black tip), the 

air shutter opening may need to be adjusted.

If  the  air  shutter  opening  is  closed  too  far, 

sooting may develop. Sooting is indicated by 

black puffs developing at the tips of very long 

orange flames.  Sooting results in black deposits 

forming on the logs, appliance inside surfaces 

and on exterior surfaces adjacent to the vent 

termination.  Sooting is caused by incomplete 

combustion in the flames and lack of combustion 

air entering the air shutter opening. To achieve 

a warm yellowish-orange flame with an orange 

body that does not soot, the shutter opening 

must be adjusted between these two extremes.  

Air Shutter Adjustment Guidelines

•   If  there  is  smoke  or  soot  present,  first 

check the log set positioning to ensure that 

the flames are not impinging on any of the 

logs.  If the log set is properly positioned 

and a sooting condition still exists, then the 

air shutter opening should be increased.

•   The more offsets in the vent system, the larger 

the air shutter opening will need to be.

•   An appliance operated with the air shutter 

opened too far, may have flames that appear 

blue and transparent.  These weak, blue and 

transparent flames are termed anemic. 

•   Propane models may exhibit flames which 

candle or appear stringy. If this is present 

and persists, adjust the air shutter to a more 

closed position, then operate the appliance 

for a few more minutes to ensure that the 

flame  normalizes  and  the  flames  do  not 

appear sooty. 

The following chart is provided to aid you in 

achieving  the  correct  air  shutter  adjustment 

for your installation.

Air Shutter Adjustment Guidelines

:

Amount of 

Primary Air

Flame 

Color

Air Shutter 

Adjustment

If air shutter is 

closed too far

Flame will 

be orange

Air shutter 

gap should be 

increased

If air shutter is 

open too far

Flame will 

be blue

Air shutter 

gap should be 

decreased

Содержание Dave Lennox Signature Montebello LSM40EN-PV

Страница 1: ...th WARNING AVERTISSEMENT AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS UNE SURFACE VITR E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROIDIR LA SU...

Страница 2: ...ce Operation Notices 6 Warranty Information 6 General Information 7 BTU Input 7 Gas Pressure Requirements 7 Orifice Sizes 7 Burn In Period 7 Operation and Care of Your Appliance 8 Appliance Operation...

Страница 3: ...ures lev es voir Page 5 Lisez la section Informations importantes relatives la s curit Page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla...

Страница 4: ...eil Les tout petits les jeunes enfants ou les adultes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes ri...

Страница 5: ...anera 1 Identifique el interruptor o el termostato de pared quecontrolalachimenea verifiquequeelinterruptor opera la chimenea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode...

Страница 6: ...nd to replace any part of the control system and any gas control that has been under water Thesefireplacesaredesignedassupple mentalheaters Therefore itisadvisable to have an alternate primary heat so...

Страница 7: ...nually modulated gas valve flame appear ance and heat output can be controlled at the gas valve The BTU Input for these appliances is shown in Table 1 Gas Pressure Requirements All Models Tables 2 and...

Страница 8: ...tches are also available see Page 15 remote wall switch remote control or wall thermostat Right Side Modesty Panel Access Plate Hi Lo Extension Knob ON OFF Switch Gas Valve WARNING Young children shou...

Страница 9: ...ch for appliance ON OFF control See Figure 1 for its location Once the pilot is lighted the ON OFF rocker switch will control the appliance ON OFF operation To operate Toggle the switch between its ON...

Страница 10: ...hree times during each heating season depending on the circumstances present The following cleaning solutions are approved for use to clean glass Non ammonia based household cleaner 50 50 mix of white...

Страница 11: ...lass Door Assembly WARNING When reinstalling the glass door the door latch screws must be securely tightened to prevent the glass door from falling out which could potentially cause damage and possibl...

Страница 12: ...ositioned properly as shown twigs will be positioned between flame peaks and will not impinge any flames Positioning is the same for all colors of log sets Figure 5 Figure 6 Glowing Embers Rockwool Fo...

Страница 13: ...rner Engage Logs 3 4 With The Grate Pins And Align Groves At The Bottom Of The Logs Over The Grate 4 3 Engage Log 6 With The Grate Pin And Align Groove At The Bottom Of The Log Over The Grate Align Ho...

Страница 14: ...shutter opening To achieve a warm yellowish orange flame with an orange body that does not soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines If the...

Страница 15: ...ratetheapplianceforaperiodoftimeasthe effect diminishes ensuring that the appliance does not develop sooty flames When satisfied that the appliance operates properly proceedtofinishtheinstallation Lea...

Страница 16: ...e installation or ap plication of this system please contact your dealer or distributor LENNOX HEARTH PRODUCTS 1508 Elm Hill Pike Suite 108 Nashville TN 37210 visit us at www Lennox com 1 800 9 LENNOX...

Страница 17: ...nds to the fireplace effortlessly with one simple motion TheModelRCLcomescompletewithdetailedoperat ing instructions Deluxe Remote Control System The Model RCL STAT Deluxe Remote Control System has al...

Страница 18: ...Kits Fits Fireplace Models Catalog No Model Mission Classic LSM40 PV LSM45 PV H2227 AKM LSM H2228 AKC LSM ref Kit Instruction P N 750 183M Classic Screen Kits These Screen kits can be installed on th...

Страница 19: ...Instructions Electronic 1 For complete shut down turn remote wall switch to OFF or set the thermostat to the lowest setting if applicable 2 Turn the ON OFF switch to OFF if Step 1 is not applicable 3...

Страница 20: ...ions de s curit sur la portion sup rieure gauche de cette tiquette 2 Tournez l interrupteur mural la position d arr t OFF ou plaez le thermostat plssible si requis 3 Tournezl interrupteur marche arr t...

Страница 21: ...the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the appropriate applian...

Страница 22: ...to valve Ensure blue and white 2 wires connection is secure to valve D Air in the gas line Purge gas line of air E Low voltage Test voltage at AC terminals of module for 24 VAC If no voltage replace...

Страница 23: ...t Is There Water Dirt In The Hose From The Blower To The Pressure Switch Are the Hose Connections Loose Is The Hose Cracked Replace Pressure Switch Replace Control Module Yes Yes Is The Lead To The Sp...

Страница 24: ...Left Side H3373 1 H3374 1 22 Floor Panel H3369 1 H3370 1 23 Bag of Volcanic Stone lava rock 80L42 1 80L42 2 24 Barrier Screen Panel H4805 1 H4806 1 25 Adaptor w Probe H7925 H7925 Contact an Authorize...

Страница 25: ...NNOX HEARTH PRODUCTS MONTEBELLO POWER VENT DV GAS FIREPLACES LSM40 45EN PV CARE AND OPERATION INSTRUCTIONS Replacement Parts ILLUSTRATIONS 25 40 42 16 7 18 8 6 5 9 17 12 4 14 13 HI LO 11 10 22 21 20 1...

Страница 26: ...7 H7384 Insulated 1 4 Male Terminal 4 8 H7371 Hose Clamp 11 32 2 15 H7372 Base Assembly Power Vent 1 16 H7378 Kicker Assembly 1 POWER VENT REPLACEMENT PARTS AND ILLUSTRATIONS Item Part Number Descript...

Страница 27: ...27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE LENNOX HEARTH PRODUCTS MONTEBELLO POWER VENT DV GAS FIREPLACES LSM40 45EN PV CARE AND OPERATION INSTRUCTIONS NOTES...

Страница 28: ...Elm Hill Pike Suite 108 Nashville TN 37210 Printed in U S A 2009 Lennox Hearth Products P N 506025 02 Rev C 06 2011 Lennox Hearth Products reserves the right to make changes at any time without notic...

Отзывы: