background image

17

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Log Set Installation Instructions

Kit Contents

(refer to Figure 30)

Cat. No. #H514

Qty

(1)   left log (B)

(1)   right log (C)

(1)   front log (D)

(2)   log support brackets (E)

cut lines

B

C

D

B

C

D

E

Bracket correctly placed

E

Figure 30

Figure 31

Figure 33

Figure 32

Tools Required

None

CAUTION:  The logs can be damaged if they are not handled 

with care!

To Install the log set:

1. Remove the two log support brackets from the box and bend the ends 

of the brackets 90 degrees at the cut lines. See 

Figure 31

.

2. One bracket goes into the left corner and the other into the right corner 

of the firebox.  Rotate the brackets so they are placed as shown in 

Figure 32

.  The bracket fits between the back of the firebox and the 

air wash at the front of the insert.

3. Remove the ceramic logs from the box and carefully unwrap them.  

Position each back log 

(Figure 33, B, C)

 in their proper place, one 

on each side against the back of the firebox.

4. The front log should face the front of the firebox with the wood grain 

showing.  It should rest on the other two back logs.  See 

Figure 33

 

for assembled log set.

Содержание Country Winslow PI40

Страница 1: ...and use of this pellet fuel burning room heater Failure to follow these instructions could result in property damage bodily injury or even death Contact your local building or fire officials to obtai...

Страница 2: ...on the maximum setting during the coldest periods of the winter DO NOT OVER FIRE THIS INSERT Follow all instructions regarding the proper use of this insert 13 CAUTION NEVER PUT FINGERS NEAR AUGER Pe...

Страница 3: ...7 Operation Page 14 19 Control Board Page 18 Filling the Hopper Page 18 Lighting Page 18 Manual Operation Page 18 Thermostat Operation Page 18 Shut Down Page 19 Paint Curing Page 19 Convection Blower...

Страница 4: ...e appliances If your local code requires a smoke detector be installed within the same room you must follow the requirements of your local code Check with your local building department for require me...

Страница 5: ...e answered at the Pellet Fuels Institute PFI www pelletheat org BTU CONTENT There are a number of variations in pellet fuels that are not included in PFI standards For example BTU heat value content m...

Страница 6: ...4mm Minimum 36 914mm Minimum Figure 1 Figure 2 Existing 8 Flue Flex Pipe Exhaust Collar 8 3 4 222mm Min W Hopper Extension 21 13 16 554mm W O Hopper Extension 18 5 16 465mm 15 381mm NOTE DIAGRAMS ILLU...

Страница 7: ...d approved through OMNI Testing Laboratories Inc 6 152mm 6 152mm 3 76mm 3 76mm 6 152mm Insert Base Firebox Front Edge Floor Protection 31 3 4 807mm 7 7 16 189mm 19 1 4 489mm 6 11 16 170mm 6 11 16 170m...

Страница 8: ...ructural integrity of the fireplace and chimney system are maintained DO NOT INSTALL A FLUE DAMPER IN THEEXHAUSTVENTINGSYSTEMOFTHISUNIT DONOTCONNECTTHIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANC...

Страница 9: ...ce regulator vent outlet min 72 1 8m K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance min 48 1 2m L Clearance to a mechanical air supply in...

Страница 10: ...nutsfromthepartsbag found in the firebox Install the six speed nuts with the flat surface forward on the six surround mounting bracket holes three on each side of the insert A flat bladed screwdriver...

Страница 11: ...ing lag screws The screws can be inserted through the holes in the base located behind the side doors If the hearth is concrete or masonry use proper lag bolts and methods designed for anchoring to ma...

Страница 12: ...side air installations The air intake on the exterior of the home should always be located substantially below the flue termination and terminate with a cover to keep out weather and pests The outside...

Страница 13: ...n each piece of trim Do not finish tightening the nuts yet See Figure 19 5 There should be approximately a 7 8 22 mm gap between the top edge of the upper trim and the top edge of the door and a 1 1 2...

Страница 14: ...rod out rotate the grill vertically with the notch to the left and slide the grill over the scraper rod slide the rod between the third and fourth bar See Figure 22 3 Rotate the grill back to the hor...

Страница 15: ...Installation Option Part 79030 Kit Contents Brick Panel A 4 Tap Tights B Tools Required Drill 90 drill recommended 18 drill bit 5 32 allen wrench Figure 26 A B 2 Remove all pellets and ash from the f...

Страница 16: ...en wrench 6 Replace the burn pot and check that it is firmly in place if you can rotate the burn pot it is not installed correctly If present install the optional log set according to the log set inst...

Страница 17: ...d bend the ends of the brackets 90 degrees at the cut lines See Figure 31 2 One bracket goes into the left corner and the other into the right corner of the firebox Rotate the brackets so they are pla...

Страница 18: ...at selector knob controls the pellet burn rate and the insert s heat output Turning the knob to setting 1 allows the insert to burn about 1 8 pounds of pellets per hour about 8 500 BTUs per hour Turni...

Страница 19: ...oods Minerals from ash and sand in the pellets form clinkers under the extreme temperatures in the burn pot Try burning various brands of pellets until you find one that burns with minimum ash and cli...

Страница 20: ...when the fireplace insert is hot To open the door follow the first two steps listed in Front Door Removal on Page 23 Clean the glass using a soft cloth or paper towel and a household glass cleaner or...

Страница 21: ...rt has a clean out box to which the flue pipe or flex pipe is at tached Toaccesstheclean outbox removetherightsidesurroundpanel and right door Figure 37 shows the box in the upright position attached...

Страница 22: ...tension and remove the extension Place the lid back over the hopper and reinstall the screws securing the lid To adjust the hopper height between the maximum and the minimum remove screws D and slide...

Страница 23: ...e 41 see C To reinstall the door repeat the steps in reverse order Side Door Removal To remove the door 1 Swing the door open 2 Lift the door up and 3 Pull the bottom of the door out and down pulling...

Страница 24: ...uger Motor The 1 25 RPM auger motor B in Figure 22 turns the auger lifting pellets up the auger tube The pellets are then dropped down a tube and into the firepot The auger is controlled by the contro...

Страница 25: ...is shipped with the adjuster in the fully open position To slow the draft down loosen the 5 32 allen head screw A in Figure 45 and move the adjuster handle toward the center of the insert Retighten t...

Страница 26: ...up Possible Problem Solution Power cord is not plugged in Plug in power cord Board fuse blown Replace 3 amp fuse located on front of control board Wall outlet not energized Check circuit breaker pane...

Страница 27: ...rd Fuse 3 Amp 5 Pack H5888 Convection Blower H5902 Convection Blower Gasket Over Temperature Snap Switch Shuts Insert Down Code Ready light flashes red 2 long blinks Possible Problem Solution Convecti...

Страница 28: ...Zero Clearance Kit Pellet Heat Kits 79024 PI40 HK Pellet Heat Kit 79026 PI40 HK30411 30 5 8 Ht x 41 Wd Surround Panels 79027 PI40 HK3048F 30 5 8 Ht x 48 Wd Surround Panels 79028 PI40 HK3441F41 34 5 8...

Страница 29: ...n the main front door and remove the 2 bolts in the front right and front left of the bottom of the fire box see Figure 49 Note Placing a level on the insert top is recommended to ensure your insert i...

Страница 30: ...then you will install the block off plate F onto the lower back panel A in the spot that is marked R in Figure 52 If you are venting out the back you will install the block off plate F onto the top p...

Страница 31: ...el C in Figure 58 2 Assembling the perimeter Figure 55 Using the sheet metal screws provided attach the left side panel B and the right side panel C to the back panel A There are 3 holes at each corne...

Страница 32: ...allation and operation manual 5 Now remove the 3 screws located across the top of the pellet hopper See Figure 59 At this time set the assembled ZC box near the back of the insert and take the power c...

Страница 33: ...xhaust Intake A C Power Cord Front View 29 1 2 16 1 8 6 3 4 8 1 4 Side View 10 3 8 19 1 2 25 1 2 16 6 3 4 4 3 1 2 8 1 4 9 1 8 39 Exhaust Top View Front 8 1 4 9 1 8 39 Outside Air Intake Exhaust A C Po...

Страница 34: ...4 Outside Air Intake Exhaust A C Power 39 9 1 8 8 1 4 10 3 8 19 1 2 25 1 2 4 3 4 3 2 1 2 Exhaust Intake A C Power Cord Front View 8 1 4 28 16 1 8 4 3 4 Side View 8 1 4 210mm 9 1 8 232mm 39 991mm 10 3...

Страница 35: ...35 NOTES...

Страница 36: ...rts See Page 27 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your Lennox Hearth Products distributor or dealer Part...

Отзывы: