![Lennox COMPACTAIR CDC Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/lennox/compactair-cdc/compactair-cdc_installation-operating-and-maintenance_1876833005.webp)
4
C
S
C
020
S
N
M
3
M
CSC
CSH
020S
CSC
CSH
025S
CSC
CSH
030S
CSC
CSH
035S
CSC
CSH
040S
CSC
CSH
045D
CSC/CDC
CSH/CDH
055D
CSC/CDC
CSH/CDH
070D
CSC/CDC
CSH/CDH
085D
CSC
CSH
100D
257
290
297
352
365
443
524
549
581
865
262
295
302
357
370
448
529
554
586
870
7600
8500
10000
12000
11700
14000
20000
21000
22000 15500+11700
CSC
CSH
020S
CSC
CSH
025S
CSC
CSH
030S
CSC
CSH
035S
CSC
CSH
040S
CSC
CSH
045D
CSC/CDC
CSH/CDH
055D
CSC/CDC
CSH/CDH
070D
CSC/CDC
CSH/CDH
085D
CSC
CSH
100D
8.25
10.1
11.8
15.5
16.9
20.2
23.5
31
33.8
42.5
1.45
1.89
2.69
2.69
2.69
3.63
5.38
5.38
7.26
7.75
9.7
11.99
14.49
18.19
19.59
23.83
28.98
36.38
41.06
50.25
15
21
22
25.6
31
42
44
51.2
62
77.6
2.59
3.45
4.8
4.8
4.8
6.48
9.6
9.6
12.96
13.4
17.59
24.45
26.8
30.4
35.8
48.48
53.6
60.8
74.96
91
88.4
97.8
105.1
139.1
152.7
121.8
131.9/
210.2
169.5/
278.2
191.9/
308.8
207.9
3~400V 50Hz
1.- GENERAL CHARACTERISTICS
1.1.- PHYSICAL DATA
Unit
COMPACTAIR
C: Cooling only
H: Heat pump
Type of refrigerant
M: R-410A
Approximate cooling
capacity in kW
S: Outdoor unit Split
D: Outdoor unit Multi-split
S: One Circuit
D: Two Circuits
No heat
Number
of revision
M: 400V/3/50
CSC/CDC: Cooling only unit R-410A.
CSH/CDH: Heat pump unit R-410A.
UNIT MODELS
Compressor (Nr. / Type) 1/Scroll 1/Scroll 1/Scroll 1/Scroll 1/Scroll 2/Scroll 2/Scroll 2/Scroll 2/Scroll 2/Scroll
Net Weight
(Kg)
CSC/CDC Cooling only unit (Kg.)
CSH/CDH Heat pump unit (Kg.)
Air flow (m
3
/h)
Refrigerant charge
NITROGEN(*)
(*) The units are supplied with nitrogen gas; this must be
removed and the unit charged with refrigerant R-410A,
depending on unit model.
(see page 23 to calculate refrigerant charge for model CSC/
CDC and CSH/DCH units to work with indoor units CIC/CIH).
R-410A factory refrigerant precharge kit is available as an
option.
1.2.- ELECTRICAL DATA
ELECTRICAL CONSUMPTION FOR STANDARD UNITS
UNIT MODELS
Maximum absorbed power
(kW)
Compressor
Fan
Total power
Maximum current
(A)
Compressor
Fan
Total current
Start up current
(A)
Voltage V/f (50Hz)
1.3.- OPERATING LIMITS
(For installation with CIC-CIH units)
OPERATING LIMITS FOR (COOLING ONLY) UNITS
COOLING CYCLE
OPERATION
INDOOR TEMPERATURE
OUTDOOR TEMPERATURE
MAXIMUM TEMPERATURES
MINIMUM TEMPERATURES
+10ºC STANDARD UNIT
0ºC (*)
-15ºC (**)
INDOOR TEMPERATURE
MAXIMUM TEMPERATURES
COOLING CYCLE
OPERATION
HEATING CYCLE
OPERATION
INDOOR TEMPERATURE
OUTDOOR TEMPERATURE
27ºC
(With 20ºC outdoor temperature)
(*) With option kit low temperature 0ºC.
(**) With option kit low temperature -15ºC.
OPERATING LIMITS FOR (HEATING PUMP) UNITS
DB: Dry bulb temperature.
WB: Wet bulb temperature
(*) With option kit low temperature -15ºC.
MINIMUM TEMPERATURES
OUTDOOR TEMPERATURE
32ºC DB / 23ºC WB
21ºC DB / 15ºC WB
27ºC DB
32ºC DB / 23ºC WB
15ºC DB
21ºC DB / 15ºC WB
-12ºC
(With 20ºC indoor temperature)
45ºC (020-025-030-045-055)
47ºC (035-040-070-085-100)
45ºC (020-025-030-045-055)
47ºC (035-040-070-085-100)
0ºC UNIDAD ESTÁNDAR
-15ºC (*)