15
Parameter Settings Based on System
Configuration
The first parameters (S-Bus Address) will always
need to be set. Available bus addresses are 1
through 31.
Other settings are available based on whether oper-
ations with smart hub and local scheduling functions
is set to ON or OFF.
The second and third parameter is operation with
smart hub and local scheduling.
That option is either ON or OFF for both. Default
is OFF for both. Available parameters settings are
dependent on whether either parameter is ON or
OFF. See the following table to determine available
parameters based on OFF or ON.
Table 4.
Parameter Settings based on System Configuration
Parameters
Setting Available when
Operation with Smart Hub is
ON or OFF
Setting Available when
Local Scheduling is set
to ON or OFF
Display on home screen
ON or OFF
ON or OFF
Contractor info
ON or OFF
ON or OFF
Temperature sensor config.
ON or OFF
ON or OFF
Smooth setback recovery (SSR)
OFF
ON
Offsets
ON or OFF
ON or OFF
Temperature adjustment range
ON or OFF
ON or OFF
Remember override set point
OFF
ON
Schedule hold setting
OFF
ON
Reminders
OFF
ON or OFF
Reset to factory defaults
ON or OFF
ON or OFF
Change owner pin
ON or OFF
ON or OFF
RTU fan on/auto user control
ON or OFF
ON or OFF