INTRODUCTION

This installation and maintenance booklet should always accompany the air treatment unit for ready consultation by
the installer or user if necessary.
The unit should be installed in compliance with the regulations in force in each country and according to the manufacturer's
or qualified person's instructions.
The manufacturer cannot be held liable for any damage to property or injury to persons and animals caused by incorrect
installation of the unit.
Only  qualified  persons  should  install  the  unit  and  connect  it  to  the  mains  electricity  supply.
Before  carrying  out  any  work  on  the  unit,  ensure  that  it  is  disconnected  from  the  electricity  supply.
Read this instruction booklet prior to installation.

RECOMMENDATIONS

This unit is easy to use, but it is important to read all the contents of this guide before using it for the first time. This
will help you to:
- use the unit in all safety
- obtain best performance
- avoid incorrect actions
- respect the environment
Do not allow children or unassisted handicapped persons to use the unit.
Do not touch the unit with wet parts of the body or if barefoot.
Do not tug, pull or twist electrical cables attached to the unit, even when disconnected from the electricity supply.
Do not open the flaps giving access to the internal parts of the unit without having first put the system on-off switch to
"off".
Do not introduce sharp pointed objects through the air intake and outlet grilles.
Do not leave packing material (boards, staples, plastic bags, etc.) within reach of children since they could be a source
of danger. Dispose of correctly.
Do not spray or throw water directly on the unit.
Do not use the unit in places with suspended dust/powder or in potentially explosive atmospheres, in very damp
environments  or  in  the  presence  of  oil  in  suspension  or  in  particularly  aggressive  atmospheres.
Do not cover the unit with objects or drapes that even partially obstruct the air flow.

The unit works by electricity at mains voltage (230 Vac, 50 Hz). Always bear in mind that mains voltage is potentially
dangerous and any appliance connected to it should be used with caution. Before carrying out any work on the unit,
disconnect it from the electricity supply (by pulling out the plug from the mains socket or isolating the supply line by
putting the on-off switch to off).
If the unit is not be used for long periods, make sure that the controls are in the position 0 (off). If the unit is not going
to be used in winter when temperatures are near to freezing, drain the system and ensure that the unit heat exchanger
has no water in it in order to prevent the formation of ice and consequent breakage.
To make the unit inoperable, disconnect it totally from the electricity supply.
It is unsafe to alter or try to alter the characteristics of this product. Any tampering or alteration in any case makes the
warranty null and void.
In the event of malfunction or failure, do not try to repair the unit yourself; contact a qualified technician. Repairs carried
out by incompetent persons could cause damage or accidents.
Always  keep  the  unit  clean.  In  particular  clean  the  air  filter  periodically  (at  least  once  a  month).
.

FAILURE TO COMPLY WITH THE ASSEMBLY INSTRUCTIONS GIVEN IN THIS

GUIDE RELIEVES 

LENNOX 

OF ALL AND ANY LIABILITY. INCORRECT

INSTALLATION COULD CAUSE MALFUNCTIONING OR FAILURE OF THE UNIT.

IT COULD ALSO REPRESENT A HAZARD FOR THE USER.

!

INSTALLATION 

- OPERATING & 

MAINTENANCE

 MANU

A

L

 

Page 

2

 

All manuals and user guides at all-guides.com

Содержание COMFAIR-HH

Страница 1: ...Providing indoor climate comfort COMFAIR HH HH IOM 0304 E Installation operating and maintenance All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 2: ...All manuals and user guides at all guides com ...

Страница 3: ...on of the air treatment unit 6 7 Installation of the accessories for ducting the air treatment unit 7 9 WATER CONNECTIONS Connection to the trunk line 10 Condensate water drainage 10 ELECTRICAL CONNECTIONS Recommendations Connections to the terminal blocks 11 13 TURNING THE COIL 14 SECOND PART FOR THE USER CLEANING AND MAINTENANCE Routine maintenance 15 Cleaning the air filter 15 WHAT TO DO IF 16 ...

Страница 4: ...Do not use the unit in places with suspended dust powder or in potentially explosive atmospheres in very damp environments or in the presence of oil in suspension or in particularly aggressive atmospheres Do not cover the unit with objects or drapes that even partially obstruct the air flow The unit works by electricity at mains voltage 230 Vac 50 Hz Always bear in mind that mains voltage is poten...

Страница 5: ... be reported to the carrier by affixing an accepted with reservation on the accompanying note specifying the type of damage In the event of prolonged storage keep the units protected against dust and far from sources of vibration or heat The number of units that may be positioned on one pallet are given in the table table 1 SAFETY PROVISIONS Secure packs during transportation Do not expose to the ...

Страница 6: ...SP SRE PAM BAM RAM B B 50 50 B 50 50 B B B 50 50 B 50 50 204 26 26 A 11 11 A 11 11 341 A 115 204 26 26 A 11 11 A 11 11 70 A ØBAM 30 B 51 51 L B 51 51 44 44 P 26 H A 29 29 76 26 A 76 ØAF ØAC ØC Fig 2 GENERAL SIZE OF THE BASE UNIT GENERAL SIZE OF DUCTWORK ACCESSORIES INSTALLATION OPERATING MAINTENANCE MANUAL Page 4 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 7: ...international safety standards It comes complete with safety thermostat with automatic reset interface control relay wiring and control panel with on off magnetothermal switch FAM Connecting flange GAM Vibration isolation joint PAM Straight intake delivery plenum BAM Intake delivery union with circular fittings RAM 90 intake delivery plenum SFA Air filter section Filtering membrane enclosed within...

Страница 8: ...here is a circuit breaker switch readily accessible to the user to cut off the power supply whenever necessary 6 the circuit breaker is in the OFF position so that there is no voltage on the unit supply line Fig 4 Fig 5 Drill the holes in line with the relative slots for the 6 unit screw anchors fig 4 Inject thermosetting resin into the holes and then insert the screw anchors fig 5 Preliminary ope...

Страница 9: ... for accomplishing the installation are NOT included in the supply of the air treatment unit INSTALLATION OF THE ACCESSORIES LEGEND 1 RAM 90 intake delivery plenum 2 BAM intake delivery union with circular fittings 3 PAM straight intake delivery plenum 4 SRE heating section with electric heating element 5 GAM vibration isolation joint 6 FAM connecting flange 7 UTC base unit 8 SFA air filter sectio...

Страница 10: ...r intake section SSP into the air filter section SFA by means of the male female coupling After having secured it with the self tapping screws 4 2 x 9 5 galvanised anchor it to the ceiling as illustrated for the base unit in figures 4 7 Put another connecting flange on the vibration isolation joint GAM and secure it using cheese headed screws M8x16 and hexagon bolts Insert the straight delivery pl...

Страница 11: ... and hexagon bolts Insert the straight delivery plenum PAM in the connecting flange and fix it using galvanised self tapping screws 4 2 x 9 5 Then connect the 90 plenum RAM with the procedure described above Fig 12 The heating section with electric heating element SRE is usually placed on the delivery side before the straight delivery plenum PAM It may be used either with the delivery union BAM or...

Страница 12: ...ration the solenoid valve stops the circulation of water when the set temperature is reached thus stopping the internal exchanger from continuing to condense water with possible undesirable dripping onto the floor It also reduces chiller operation with consequent energy saving CONNECTION TO THE TRUNK LINE Fig 13 Fig 14 WATER CONNECTIONS The condensate drain pipe should slope downwards by at least ...

Страница 13: ...uld be sufficiently long so that they are not permanently taut or create throttling or compression on metal parts The power cables should be sufficiently long so that in the event of accidental tugging the active wires are subjected to stress before the earth wire Connect the earth wire to the relative terminal marked with the symbol Check the earth connection Comply with the safety regulations in...

Страница 14: ... II Medium speed blue III Maximum speed black Com Common white 25 26 27 28 1 2 3 4 Relay interface card 14 15 16 17 M I II III com com I II III 230 V 1 50 Hz motor power supply N Ph T T CAUTION FAILURE TO COMPLY WITH THE INDICATED CONNECTIONS MAY CAUSE MOTOR BURNOUT Fig 17 INSTALLATION OPERATING MAINTENANCE MANUAL Page 12 All manuals and user guides at all guides com ...

Страница 15: ... 3 A2 1 3 3 3 2 2 1 1 M1 M2 T LEGEND Ph Phase brown N Neutral blue T Earth yellow green M1 M2 Fan motor Com Common white I Minimum speed red II Medium speed grey III Maximum speed black R1 Relay R2 Relay R3 Relay CAUTION FAILURE TO COMPLY WITH THE INDICATED CONNECTIONS MAY CAUSE MOTOR BURNOUT Fig 18 INSTALLATION OPERATING MAINTENANCE MANUAL Page 13 All manuals and user guides at all guides com ...

Страница 16: ... relative grommet If it proves easier to carry out this operation by separating the wires from the terminal blocks mark the positions of the wires to avoid making mistakes when reconnecting 9 Reconnect the wires to the relative terminal blocks 6 taking care that they are correctly positioned 10 Replace the condensate collecting tray 2 1 3 4 5 6 3 2 TURNING THE COIL CAUTION The fan wheels may reach...

Страница 17: ...otor works without unusual vibrations or noise and that the fan inlet is not obstructed which could otherwise leading to overheating of the windings Check the fans for dirt or any foreign matter CLEANING THE AIR FILTER The unit is fitted with an air filter on the fan inlet During normal operation the filter holds back impurities in the air The filter should be cleaned periodically to keep its filt...

Страница 18: ... of the environment WHAT TO DO IF There is little outflowing air Incorrect speed setting on the control panel select the right speed Clogged filter clean the filter Obstruction of the airflow on the intake or delivery line remove obstruction The motor does not turn Check that the power supply is switched on the switches or thermostats are in the correct operating position there is no foreign matte...

Страница 19: ...All manuals and user guides at all guides com ...

Страница 20: ...BOURG CZECH REPUBLIC FRANCE GERMANY NETHERLANDS POLAND PORTUGAL RUSSIA SLOVAKIA SPAIN UKRAINE UNITED KINGDOM AND IRELAND OTHER COUNTRIES Due to Lennox s ongoing commitment to quality the Specifications Ratings and Dimensions are subject to change without notice and without incurring liability Improper installation adjustment alteration service or maintenance can cause property damage or personal i...

Отзывы: