Page 6
CBX32MV
CBX32MV‐036
BLOWER MOTOR WATTS AT NORM SETTING
(Adjust Jumper at NORM Setting)
Jumper Speed Positions
Motor Watts @ Various External Static Pressures - in. wg. (Pa)
0 (0)
0.1 (25)
0.2 (50)
0.3 (75)
0.4 (100)
0.5 (125)
0.6 (150)
0.7 (175)
0.8 (200)
HEAT
Speed
Tap 1
155
185
215
240
265
285
300
335
355
Tap 2
225
245
270
295
325
345
370
390
415
Tap 3
275
290
315
340
375
400
420
445
465
Tap 4
320
345
375
405
435
460
485
515
540
COOL
Speed
Tap 1
120
140
160
190
210
230
255
275
300
Tap 2
160
190
220
240
265
290
320
340
365
Tap 3
255
270
295
320
345
375
400
420
445
Tap 4
320
345
375
405
435
460
485
515
540
CBX32MV‐036
BLOWER MOTOR WATTS AT - (Minus) SETTING
(Adjust Jumper at - Setting)
Jumper Speed Positions
Motor Watts @ Various External Static Pressures - in. wg. (Pa)
0 (0)
0.1 (25)
0.2 (50)
0.3 (75)
0.4 (100)
0.5 (125)
0.6 (150)
0.7 (175)
0.8 (200)
HEAT
Speed
Tap 1
120
135
165
185
205
225
245
265
300
Tap 2
140
165
195
215
245
270
300
315
335
Tap 3
185
210
240
265
285
310
330
360
385
Tap 4
245
255
290
310
335
355
380
405
430
COOL
Speed
Tap 1
90
110
135
155
180
195
210
230
250
Tap 2
120
140
160
185
215
235
255
275
295
Tap 3
160
190
225
240
275
295
320
350
380
Tap 4
245
255
290
310
335
355
380
405
430
CBX32MV048 and CBX32MV060 BLOWER PERFORMANCE
0 through 0.80 in. w.g. External Static Pressure Range
“AJUST”
Jumper Setting
Jumper Speed Positions
“HEAT” Speed
“COOL” Speed
1
2
3
4
1
2
3
4
+
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
NORM
1850
1960
2090
2150
1625
1820
2055
2145
-
1705
1800
1900
2005
1425
1625
1805
2005
1560
1625
1720
1770
1205
1375
1555
1725
NOTES:
The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.
First stage cooling air volume is 70% of COOL speed settings. Continuous fan speed is approximately 28%, 38%, 70% and 100% (Jumper
selectable) of the same secondstage COOL speed selected, minimum 450 cfm.
Lennox Harmony III™ Zone Control applications - minimum blower speed of 450 cfm.
CBX32MV‐048 AND CBX32MV‐060
BLOWER MOTOR WATTS AT + (Plus) SETTING
(Adjust Jumper at + Setting)
Jumper Speed Positions
Motor Watts @ Various External Static Pressures - in. wg. (Pa)
0 (0)
0.1 (25)
0.2 (50)
0.3 (75)
0.4 (100)
0.5 (125)
0.6 (150)
0.7 (175)
0.8 (200)
HEAT Speed
Tap 1
455
505
540
585
630
665
710
745
780
Tap 2
555
595
645
675
730
780
820
865
895
Tap 3
680
720
770
820
865
900
945
985
1030
Tap 4
730
780
825
870
920
970
1020
1055
1110
COOL Speed
Tap 1
300
335
370
360
435
465
500
535
575
Tap 2
425
475
500
545
585
635
670
710
745
Tap 3
625
660
705
755
810
850
885
940
970
Tap 4
700
750
800
845
895
940
990
1030
1080