background image

Page 2

506960−−01 02/12

Installation

ENHANCED
BALLAST
CORD

LAMP CORD

CONNECTOR

DISCONNECT

CONNECT

Figure 1. Disconnect/Connect Lamp Cord

LOCK POSITION

ALIGN
POSITION

LAMP
BASE

LAMP
HOLDER

1" HOLE

ROTATE TO UNLOCK

Figure 2. Removing the lamp holder assembly

1. Turn off power to the lamp before removing the cord.
2. Disconnect the lamp cord as shown in figure 1.
3. Unlock the lamp holder as shown in figure 2. Set the

lamp holder and lamp aside.

4. Remove the lamp base as  shown in figure 3.
5. Install new lamp base assembly as shown in figure 3.

LAMP BASE

MOUNTING
SCREWS

I INCH
HOLE

Figure 3. Remove and Install Lamp Base

BAFFLE
TROUGH

LAMP

SCREWS

MOUNTING
SURFACE

LAMP BASE

GUIDE LAMP TIP ALONG
THE SURFACE OF THE
TROUGH

LAMP
HOLDER

BAND

CLASP

Figure 4. Guiding Lamp into Shielding Baffle

6. Align arrow on lamp holder with arrow on lamp base.

Insert lamp holder into base (see A in figure 5).

7. Twist to align lamp holder arrow with lock symbol (see

B in figure 5).

LAMP
BASE

APPROX. 
30 DEG.
ROTATION

A

B

Figure 5. Locking Lamp in Place

8. Connect the lamp holder cord’s quick connect to the

mating enhanced ballast connector (see figure 1).

9. Turn on power and check operation and that LEDs on

ballast are lit.