background image

Page 4

# 48283B006

Table 2

Refrigerant Line Set Diameters (in.)

For installations exceeding 50', contact

Technical Services at (419) 483-4840.

e

n

i

L

n

o

i

t

c

u

S

H

U

T

B

e

z

i

S

d

n

a

h

t

g

n

e

L

t

e

S

e

n

i

L

.

t

f

2

1

.

t

f

5

2

.

t

f

0

5

.

t

f

5

7

.

t

f

0

0

1

0

0

0

,

8

1

4

/

3

4

/

3

4

/

3

4

/

3

4

/

3

0

0

0

,

4

2

4

/

3

4

/

3

4

/

3

4

/

3

8

/

7

0

0

0

,

0

3

4

/

3

4

/

3

4

/

3

8

/

7

8

/

7

0

0

0

,

6

3

8

/

7

8

/

7

8

/

7

8

/

7

8

/

1

-

1

0

0

0

,

2

4

8

/

7

8

/

7

8

/

7

8

/

1

-

1

8

/

1

-

1

0

0

0

,

8

4

8

/

7

8

/

7

8

/

7

8

/

1

-

1

8

/

1

-

1

0

0

0

,

0

6

8

/

1

-

1

8

/

1

-

1

8

/

1

-

1

8

/

1

-

1

8

/

1

-

1

e

n

i

L

d

i

u

q

i

L

H

U

T

B

e

z

i

S

d

n

a

h

t

g

n

e

L

t

e

S

e

n

i

L

.

t

f

2

1

.

t

f

5

2

.

t

f

0

5

.

t

f

5

7

.

t

f

0

0

1

0

0

0

,

8

1

8

/

3

8

/

3

8

/

3

8

/

3

8

/

3

0

0

0

,

4

2

8

/

3

8

/

3

8

/

3

8

/

3

8

/

3

0

0

0

,

0

3

8

/

3

8

/

3

8

/

3

8

/

3

2

/

1

0

0

0

,

6

3

8

/

3

8

/

3

8

/

3

8

/

3

2

/

1

0

0

0

,

2

4

8

/

3

8

/

3

8

/

3

2

/

1

2

/

1

0

0

0

,

8

4

8

/

3

8

/

3

8

/

3

2

/

1

2

/

1

0

0

0

,

0

6

8

/

3

8

/

3

8

/

3

2

/

1

2

/

1

Installing Refrigerant Line

During the installation of an air conditioning system, it is
important to properly isolate the refrigerant line to prevent
unnecessary vibration. Line set contact with the structure
(wall, ceiling, or floor) may cause objectionable noise
when vibration is translated into sound. As a result, more

suction riser to maintain minimum velocity at minimum
capacity. Recommended line length is 50' or less. If more
than 50' line set is required, contact Technical Services at
(419) 483-4840.

Table 2 shows the diameters for line sets up to 100'
although vertical lift applications and trapping require-
ments need to be reviewed with Technical Services for
line sets over 50'.

energy or vibration can be expected. Close attention to
line set isolation must be observed.

Following are some points to consider when placing and
installing a high-efficiency outdoor unit:

Placement

Be aware that some localities are adopting sound ordinances
based on how noisy the unit is at the neighbor’s home, not at
the original installation. Install the unit as far as possible from
the property line. When possible, do not install the unit
directly outside a bedroom window. Glass has a very high
level of sound transmission. Figure 5 shows how to place the
outdoor unit and line set to reduce line set vibration.

Outside Unit Placement

and Installation

Figure 5

Install unit away

from windows

Two 90° elbows installed in lineset
will reduce lineset vibration

Line Set Isolation

Illustrations on the following pages demonstrate proce-
dures which ensure proper refrigerant line set isolation.
Figure 6 shows how to install line sets on horizontal runs.
Figure 7 shows how to make a transition from horizontal
to vertical. Figure 8 on page 6 shows how to install line
sets on vertical runs.

Brazing Connection Procedure

1. Cut ends of refrigerant lines square (free from nicks

or dents). Debur the ends. The pipe must remain
round; do not pinch end of line.

2. Before making line set connections, use dry nitrogen to

purge the refrigerant piping. This will help to prevent
oxidation and the introduction of moisture into the system.

Содержание 2SCU13 Series

Страница 1: ...trical shock Disconnect all remote power supplies before installing or servicing any portion of the system Failure to disconnect power supplies can result in property damage personal injury or death W...

Страница 2: ...or inspection by the carrier s agent If any damages are discovered and reported to the carrier DO NOT INSTALL THE UNIT as claim may be denied Check the unit rating plate to confirm specifications are...

Страница 3: ...rcuit connections are made to the low voltage pigtails A complete unit wiring diagram is located inside the unit control box cover see also pages 16 and 17 of this instruction 3 Install room thermosta...

Страница 4: ...although vertical lift applications and trapping require ments need to be reviewed with Technical Services for line sets over 50 energy or vibration can be expected Close attention to line set isolat...

Страница 5: ...line Floor Joist or Roof Rafter Metal Sleeve Floor Joist or Roof Rafter Tape or Wire Tie Wire Tie around vapor line only Refrigerant Line Sets Installing Horizontal Runs Figure 7 Refrigerant Line Sets...

Страница 6: ...t damage to the valve core and opening port The tube end must stay bottomed in the fitting during final assembly to ensure proper seating sealing and rigidity 7 Install the factory supplied fixed orif...

Страница 7: ...id and Suction Line Service Valves The liquid line and suction line service valves and service ports are used for leak testing evacuating charging and checking charge Each valve is equipped with a ser...

Страница 8: ...e line set connections and indoor unit must be checked for leaks Ball Type Service Valve Valve Open Figure 11 Use adjustable wrench To open rotate stem counterclockwise 1 4 turn 90 To close rotate ste...

Страница 9: ...HCFC 22 into the line set and indoor unit Weigh in a trace amount of HCFC 22 A trace amount is a maximum of 2 oz of refrigerant or 3 lbs pressure Close the valve on the HCFC 22 cylinder and the valve...

Страница 10: ...d has been satisfied switch the thermostat to cooling mode with a set point of 68 F When pressures have stabilized use a digital thermometer to record the liquid and suction line temperatures 6 The ou...

Страница 11: ...e F _____ Saturation Temperature F _____ Liquid Line Temperature F _____ Subcooling Value F r o o d t u O p m e T F F 1 g n i l o o c b u S d i u q i L 8 1 4 2 0 3 6 3 2 4 8 4 0 6 5 6 3 1 3 1 7 4 1 5...

Страница 12: ...e 7 Approach Values for TXV Systems Approach value is the liquid line temperature minus the outdoor ambient temperature 1 F NOTE For best results use the same digital thermometer to check both outdoor...

Страница 13: ...1 8 8 6 2 9 7 8 6 2 4 8 5 6 2 5 8 7 7 2 1 8 F 5 1 1 4 9 2 6 8 7 0 3 5 8 9 9 2 3 8 9 0 3 1 8 8 0 3 5 8 3 0 3 6 8 8 1 3 3 8 C F R e c i f i r O d e x i F F 5 6 4 4 1 3 7 7 4 1 8 6 0 4 1 6 6 0 5 1 7 6 7...

Страница 14: ...or correct voltage at unit with unit operating 6 Check amp draw outdoor fan motor Unit nameplate _________ Actual _________ NOTE If owner complains of insufficient cooling the unit should be gauged an...

Страница 15: ...nician ________________________________________ Nameplate Voltage ______________ Rated Load Ampacity ________ Compressor _______________ Outdoor Fan ___________________ Maximum Fuse or Circuit Breaker...

Страница 16: ...OCAL CODES OUTDOOR FAN F C H 1 2 3 R S C C 2 3 1 EQUIPMENT GROUND HR1 L2 208 230 60 1 L1 K1 1 BLACK YELLOW RED RED C12 BLACK ORANGE B4 PURPLE K1 S4 S24 A4 C Y1 TO 24 VAC POWER SOURCE 20 VA MINIMUM NEC...

Страница 17: ...2 L3 EQUIPMENT GROUND HR1 S40 K1 1 BLACK BLACK B1 BLACK ORANGE BLACK B4 C1 PURPLE RED 1 FOR USE WITH COPPER CONDUCTORS ONLY REFER TO UNIT RATING PLATE FOR MINIMUM CIRCUIT AMPACITY AND MAXIMUM OVERCURR...

Страница 18: ...the only warranty made by the warrantor this warranty is in lieu of and excludes all other warranties express or implied The warrantor does not authorize any person to provide any other warranty or to...

Отзывы: