Lennox Hearth Products X-FIRES-WS-LP Скачать руководство пользователя страница 7

7

PACKAGING LIST

Quantity       Description

Fireplace

  1 

Firebox, burner assembly and outer case (wrap)

  1  

Installation and Operation Manual

  1 

Warranty Certificate

  1 

Screw and wall plug pack

  1 

Rubber grommet

Surround Assembly 

(required - sold separately. see Page 21 for ordering information)

     1 

Surround Assembly

     1 

Installation Instruction Sheet

APPLIANCE SPECIFICATIONS

X-Fires™ Wide Screen

Gas Type

Natural Gas

Propane Gas

Gas inlet pressure

 

Max.

 

Min.

10.5” w.c.

6” w.c.

13” w.c.

11” w.c.

Regulator Pressure Setting

5” w.c.

10” w.c.

Max Energy Input

11,950 BTU/hour

10,235 BTU/hour

Min Energy Input

6,820 BTU/hour

6,820 BTU/hour

Pilot Energy Input

560 BTU/hour

560 BTU/hour

Main burner flow restrictor

(burner orifice)

1.55 mm (0.063”)

1.03mm (0.042”)

Oxypilot

SIT/Bray 9082

SIT/Bray 9284

Gas Inlet Connection

3/8” NPT at regulator

3/8” NPT at regulator

Ignition

Double Piezo spark

Double Piezo spark

Spark Gap

1/8” - 3/16”

1/8” - 3/16”

Please see Data Plate affixed to appliance for current data. This appliance is for use 

only with the gas type, and at the pressure stated on the appliance Data Plate.

Table 1

BURN-IN PERIOD

On initial light up of a new appliance, the ‘newness’ will burn off within 

the first few hours of operation . During this period some smoke may be 

emitted from outlet grill, this should be no cause for concern .  Accord-

ingly, the room should be well ventilated with all windows and doors 

open during this period . 
Depending on your use, the burn-in period may take a few hours or a few 

days .  Also if you have a sensitive sense of smell you may notice slight 

odors during operating after the burn-in period is over .

KEEP YOUR HOUSE WELL VENTILATED DURING THE BURN-IN PERIOD.  

THE ODOR AND HAZE EMITTED DURING THE BURN-IN PERIOD CAN BE 

QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR.  MAKE 

SURE  SMOKE  DETECTORS  ARE  NOT  TOO  CLOSE  TO  THE  FIREBOX 

(CHECK WITH YOUR LOCAL CODE FOR ALLOWABLE DISTANCES).

CODES

Adhere to all local codes or in their absence the latest edition of The 

National Fuel Gas Code ANSI Z223 .1 / NFPA 54 - latest edition which can 

be obtained from The American National Standards Institute, Inc . (1430 

Broadway, New York, NY, 10018) or National Fire Protection Association, 

Inc . (Batterymarch Park, Quincy, MA, 02269) . 

Seller  of  unvented  propane  or  natural  gas  fired  supplemental  room 

heaters in the Commonwealth of Massachusetts shall provide to each 

purchaser a copy of 527 CMR 30 upon sale of the unit . 

This Lennox Hearth Products Unvented Gas Room Heater is certified by 

OMNI-Test Laboratories, Inc to ANSI Z21 .11 .2 standard .

Massachusetts Requirements

These fireplaces are approved for installation in the US state of Mas-

sachusetts if the following additional requirements are met:

•   Unvented Room Heaters shall be installed in accordance with 527 

CMR and 248 CMR:

•   Installation and repair must be done by a plumber or gas fitter licensed 

in the Commonwealth of Massachusetts

•   The flexible gas line connector used shall not exceed 36 inches (92 

centimeters) in length .

•   The individual manual shut-off must be a T-handle type valve .

•   Vent-Free appliances may NOT be installed in bedrooms or bathrooms .

•   A working smoke detector must be installed in the area where vent-

free appliances are installed . 

Seller of unvented propane or natural gas-fired supplemental room heaters 

shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit .

New York:

These fireplaces are approved for installation in the US state of New York, 

but not in New York City .

UNPACKING THE APPLIANCE

Remove the straps and the top lid of the outer packaging, remove any 

instructions or fixing kits . Read ALL these instructions before continuing 

to unpack or install this appliance .
Lift off the remaining packaging components .
Check that the components supplied with the packaging list on 

Page 7

 . 

Please dispose of all the packaging materials at your local recycling center .

Содержание X-FIRES-WS-LP

Страница 1: ...ouvezrejoindrelefournisseurdegaz appelez le service des incindies L installation et l entretien doivent être assurés par un installateur ou un service d entretien qualifié ou par le fournisseur de gaz AVERTISSEMENT Assurez vousdebiensuivrelesinstruc tions données dans cette notice pour réduire au minimum le risque d incindie ou d explosion ou pour éviter tout dommage matériel toute blessure ou la ...

Страница 2: ...y years of dependable and enjoyable service from your fireplace Safety and Your Fireplace 2 3 Important Safety Information 4 Appliance Installation Service and Maintenance Notices 5 Appliance Operation Notices 5 Warranty Information 5 General Information 5 6 Packaging List 7 Appliance Specifications 7 Unpacking the Appliance 7 Burn in Period 7 Codes Massachusetts and New York 7 Combustion And Vent...

Страница 3: ...tives à la sécurité Page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTRÊMEMENT CHAUDES Instale una malla o barrera física para evitar el contacto directo con el vidrio y prevenir las quemaduras y lesiones graves Ver los detalles a la izquierda para ordenar un Lennox SAFETY GUARD GRATIS para su chimenea Siga las instrucciones de seguridad a continuación y asegúrese de qu...

Страница 4: ...ec la surface chaude Il est recommandé d installer une barrière physique si des personnes à risques habitent la maison Pour empêcher l accès à un foyer ou à un poêle installez une barrière de sécurité cette mesure empêchera les tout petits les jeunes enfants et toute autre personne à risque d avoir accès à la pièce et aux surfaces chaudes 7 Tout écran ou protecteur retiré pour permettre l entretie...

Страница 5: ...ppliance is Not convertible for use with other gases These appliances are designed to operate on natural gas or propane gas only The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous Provide adequate clearances around air openings and adequate accessibility clearance for service and proper operation Never obstruct the front openings of the...

Страница 6: ...es equal to or less than 1 2 psi 3 5 kPa InputratingsareshowninBTUperhourandareforelevations up to 4 500 feet Do not install this heater at an elevation above 4 500 feet if the gas supply has not been derated for thatelevation Consultyourlocalgassupplier Foroperation at elevations above 4 500 feet equipment ratings shall be reduced at the rate of 4 percent for each 1 000 feet above 4 500 feet befo...

Страница 7: ...EBOX CHECK WITH YOUR LOCAL CODE FOR ALLOWABLE DISTANCES CODES Adhere to all local codes or in their absence the latest edition of The National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition which can be obtained from The American National Standards Institute Inc 1430 Broadway New York NY 10018 or National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 Seller of unvented propan...

Страница 8: ...____ volume of space ft3 50 ft3 Maximum BTU Hr the space can support Example 3072 ft3 50 ft3 61 44 or 61 440 BTU Hr the space can support 3 Add the BTU Hr of all the fuel burning appliances in the space Vent Free heater _______ BTU Hr Gas appliance 1 _______ BTU Hr Gas appliance 2 _______ BTU Hr Gas appliance 3 _______ BTU Hr Total _______ BTU Hr Example Vent free heater 1 9 000 BTU Hr Vent free h...

Страница 9: ...ne and not in conjunction with any type of combustible fire surround No combustible shelves should be positioned on the wall above the appliance It should be established that any mirrors or picture frames etc to be positioned on the wall above the appliance are able to withstand pro longed exposure to moderate heat and moisture before proceeding with their installation The wall must be structurall...

Страница 10: ...gainst corrosion Ideally factory finished protected pipe work and fittings should be used Joints should be kept to a minimum and compression fittings must not be used The pipe work installation must be tested for soundness before any protection is applied and or the pipe work and fittings are buried Remove the wall mounting plate from the back of the appliance firebox by removing the two retaining...

Страница 11: ... all times Failure to do so may result in the risk of a fire For full information refer to the instruction manual provided with the heater Note Zero clearance from bottom of heater frame required for hard combustible floors Minimum 4 clearance required to rugs or any fabric floor coverings REFER TO INSTRUCTION MANUAL IMPORTANT Fabrics curtains and drapes are not permited above the heater at any di...

Страница 12: ... wall and drill holes for the additional fixing points as required Insert either wall plugs or cavity screw fixings as required Re position the outer casing on the wall and using a bubble level to check the casing is square and level tighten all of the fixing screws fully Now with the outer casing fixed to the wall the main firebox can be secured in position The firebox is held on the outer casing...

Страница 13: ...upstream of the heater Figure 6 within the structure s piping system to prevent moisture and contaminants from passing through the pipe to the heater controls and burner Failure to do so could prevent the heater from operating reliably The heater gas inlet connection is 3 8 NPT at the regulator located below the burner in the right hand side of the heater When tightening up the joint to the regula...

Страница 14: ... periodic visual check of the pilot flame and the burner flame should be carried out The gap between the spark electrode and the pilot should be 1 8 to 3 16 to produce a good spark There should be no need to adjust this DO NOT ATTEMPT TO ADJUST THE GAP If under any circumstances the piezo electric spark fails the pilot cannot be lit manually Adjustment to the pilot is Not allowed 17 0 GAS PRESSURE...

Страница 15: ...ns are approved for use to clean glass Non ammonia based household cleaner 50 50 mix of white vinegar and water Gas fireplace stove glass cleaner PAINTED AREAS These can be cleaned using a dry cloth LIMESTONE SURFACES Remember that limestone is porous and therefore susceptible to marking in use The limestone frame may be cleaned with a small amount of warm soapy water Any stubborn stains may be re...

Страница 16: ...ge from the joints or gasket faces especially around the door It is important to note that the appliance can never be expect ed to be 100 smoke tight and small quantities of smoke may be seen in corners of joints and gasket faces etc without affecting safety when the fire is in operation Turn on the fireplace as per the operating instructions and run at maximum setting for 15 minutes Position gas ...

Страница 17: ...e pilot is located on the left side behind the burner Figure 11 The control knob is located on the lower right hand side of the outer case It is marked as shown in Figure 10 6 Depress control knob in and turn counterclockwise to the SPARK position Figure 10 and hold there for a few seconds Note If you are running the heater for the first time or after an extended period of non use it will be neces...

Страница 18: ...em with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY LIT Pilot flame shrinks when fire is on high Poor gas flow to fire check pressure with fire on high If pressure is low remove any restriction in pipe work or valve Check all pipe work are adequately...

Страница 19: ...NSTALACION DE CHIMENEAS DE PARED SIN SALIDA DE HUMOS IMPORTANT THIS APPLIANCE IS TO BE WALL HUNG ONLY DO NOT RECESS OR INSET ANY PART OF THE APPLIANCE THIS TEMPLATE IS FOR THE MARKING OF FIXING POINTS ONLY DO NOT INSTALL THE APPLIANCE WITH THIS TEMPLATE IN PLACE IMPORTANTE ESTE APARATO UNICAMENTE DEBE SER COLGADO EN UNA PARED NO EMPOTRE NINGUN ELEMENTO DE ESTE APARATO ESTA PLANTILLA SIRVE UNICAMEN...

Страница 20: ...is heater may result in property damage or personal injury Figure 13 Visual check for cor rect pilot flame Glass Door Removal Remove the four 4 screws indicated then lift door off Figure 12 4 off burner installation positions As our policy is one of continuous improvement and development we hope therefore you will understand we must retain the right to amend details and or specifications without p...

Страница 21: ...round 71 lb 6 15 cu ft Product Reference Information Cat No Model Ship Wt Ship Volume H7224 X FIRE WS NG 71 lb 6 07 cu ft H7225 X FIRE WS LP 71 lb 6 07 cu ft Surround Specifications 8 3 4 8 3 4 16 16 39 15 16 5 1 2 8 5 8 21 1 16 54 1 2 37 13 16 25 5 8 10 5 8 Note Limestone and Granite are natural products and therefore each piece will have its own unique character with no two pieces being quite th...

Страница 22: ...t 1 16 KEY D1 Distance from mounting surface to rear entry point D2 Distance from mounting surface to center of side entry point D3 Distance from mounting surface to regulator gas entry point D3 D1 D2 REGULATOR GAS ENTRY POINT D1 D3 D2 Finished Wall TOP VIEW Fireplace Regulator Gas Entry Point Model D1 D2 D3 X fires Widescreen 3 8 10mm 1 3 8 35mm 4 5 16 110mm GAS ENTRY POINT DIMENSIONS ...

Страница 23: ...23 NOTES ...

Страница 24: ...d through your Lennox distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any que...

Отзывы: