Lennox Hearth Products X-FIRES-WS-LP Скачать руководство пользователя страница 15

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

15

      WARNING 

Any  change  to  this  heater  or  its  controls  can  be 

dangerous.

      WARNING 

No  adjustments  are  to  be  made  to  the  ODS  pilot 

system. Tampering with this system can be extremely 

hazardous.

       

WARNING

You must keep control areas, burners and circulat-

ing air passageways of appliance clean.  Failure to 

keep the primary air opening(s) of the burner clear 

may result in sooting and property damage. Inspect 

these areas of appliance before each use.  Have 

appliance  inspected  yearly  by  a  qualified  service 

person.  Appliance may need more frequent clean-

ing due to excessive lint form carpeting, bedding 

material, etc.

7 .  Remove the burner unit, strip off the burner pipes and clean thor-

oughly .

8 .   Clean the in-line restrictor, pilot assembly and the burner tube . Clean 

the exterior of the pilot assembly with a soft brush and blow through 

the flame ports on the pilot head . Check the aeration holes are free 

from lint or dirt . Do not attempt to remove the pilot injector as this 

can cause damage . The pilot assembly is a non-serviceable item and 

should not be taken apart .  Aeration holes must be clear internally for 

proper operation . 

NEVER MODIFY OR BEND THE THERMOCOUPLE 

TO MAKE THE PILOT STAY LIT. 

Modifications are dangerous and can 

have serious unseen effects on safety . If the pilot will not stay lit there 

is a problem with dirt, the gas supply to it, or the thermocouple needs 

replacement . 

9 .  Re-assemble components .

10 . Re-connect the gas supply . Turn on the gas supply and perform a gas 

leak test using gas leak test solution . Check pilot and burner for good 

ignition .

11 . Refit the valve cover and retaining screws .

12 . Refit  the  glass  door  assembly  (see  section

  -  Positioning  of  Field 

Assembled Parts).

13 .  Refit the surround assembly as described in section

 - Fitting the 

Surround Assembly.

14 . Check the purpose provided ventilation is unobstructed . 

15 . Light the fireplace and test setting pressures .

16 .  Check safe operation of the appliance . 

NOTES:

•  The gas valve is a non-serviceable item. If it needs replacement,  

replace the burner assembly. Replacement must be original manu-

facturers parts.

•  Ensure setting pressures are as stated in Table 1 on Page 7.

GLASS PANEL

 -This can be cleaned with a suitable glass cleaner . The 

following solutions are approved for use to clean glass .

 

• Non-ammonia based household cleaner

 

• 50% -50% mix of white vinegar and water

 

• Gas fireplace/stove glass cleaner

PAINTED AREAS

 - These can be cleaned using a dry cloth .

LIMESTONE  SURFACES

:  Remember  that  limestone  is  porous  and 

therefore susceptible to marking in use . The limestone frame may be 

cleaned with a small amount of warm soapy water . Any stubborn stains 

may be removed with a diluted liquid household bleach and water solu-

tion . Superficial scratches or stubborn surface stains can be smoothed 

out using a fine grade wet and dry sandpaper . Joints may be grouted 

using a matching tile grout . The limestone frame may be sealed with 

an appropriate stone sealer (consult the retailer) . This will give some 

protection against staining such as red wine, tea or coffee, but may 

darken the stone slightly .

GRANITE SURFACES

: In everyday use, a soft lint-free duster should be 

used to keep the granite clean . Other marks, such as fingerprints may 

be removed from the granite frame by using household window-glass 

cleaner .

For specific servicing instructions, see relevant sections .

SERVICING

       

WARNING

Turn  off  the  appliance  and  allow  to  cool  before 

cleaning.  Verify proper operation after servicing.

The appliance should be checked on an annual basis to ensure it is work-

ing safely and that there is no excessive build up of soot . The frequency 

of service will depend on usage, but MUST be carried out at least once 

annually . Servicing must be carried out by a qualified person, such as 

a NFI certified technician .

Turn off the fireplace at the gas supply.  Ensure that the fireplace 

is fully cold before attempting service.  A suggested procedure for 

servicing is detailed as follows;

1 .  Lay out the dustsheet and tools .

2 .  Remove the granite or limestone surround assembly as described 

in section

 - Fitting the Surround Assembly

, only in reverse .

3 .   Remove  the  glass  door  assembly  (4  screws)  and  clean  carefully . 

Remove the valve cover plate (4 screws) .

4 .   Inspect the burner and the catalysts (see section 

- Catalysts)

 and 

clean if necessary with a soft brush . Ensure there are no defects or 

obstructions that may prevent the satisfactory flow of combustion 

products through the catalysts .

5 .  Disconnect the gas supply .  

IMPORTANT NOTE: This must be done 

by a licensed plumber or gas fitter and must conform to the require-

ments of the National Fuel Gas Code NFPA 54 / ANSI Z223.1 - latest 

edition.

6 .  Undo the four screws retaining the burner support brackets .

Содержание X-FIRES-WS-LP

Страница 1: ...ouvezrejoindrelefournisseurdegaz appelez le service des incindies L installation et l entretien doivent être assurés par un installateur ou un service d entretien qualifié ou par le fournisseur de gaz AVERTISSEMENT Assurez vousdebiensuivrelesinstruc tions données dans cette notice pour réduire au minimum le risque d incindie ou d explosion ou pour éviter tout dommage matériel toute blessure ou la ...

Страница 2: ...y years of dependable and enjoyable service from your fireplace Safety and Your Fireplace 2 3 Important Safety Information 4 Appliance Installation Service and Maintenance Notices 5 Appliance Operation Notices 5 Warranty Information 5 General Information 5 6 Packaging List 7 Appliance Specifications 7 Unpacking the Appliance 7 Burn in Period 7 Codes Massachusetts and New York 7 Combustion And Vent...

Страница 3: ...tives à la sécurité Page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTRÊMEMENT CHAUDES Instale una malla o barrera física para evitar el contacto directo con el vidrio y prevenir las quemaduras y lesiones graves Ver los detalles a la izquierda para ordenar un Lennox SAFETY GUARD GRATIS para su chimenea Siga las instrucciones de seguridad a continuación y asegúrese de qu...

Страница 4: ...ec la surface chaude Il est recommandé d installer une barrière physique si des personnes à risques habitent la maison Pour empêcher l accès à un foyer ou à un poêle installez une barrière de sécurité cette mesure empêchera les tout petits les jeunes enfants et toute autre personne à risque d avoir accès à la pièce et aux surfaces chaudes 7 Tout écran ou protecteur retiré pour permettre l entretie...

Страница 5: ...ppliance is Not convertible for use with other gases These appliances are designed to operate on natural gas or propane gas only The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous Provide adequate clearances around air openings and adequate accessibility clearance for service and proper operation Never obstruct the front openings of the...

Страница 6: ...es equal to or less than 1 2 psi 3 5 kPa InputratingsareshowninBTUperhourandareforelevations up to 4 500 feet Do not install this heater at an elevation above 4 500 feet if the gas supply has not been derated for thatelevation Consultyourlocalgassupplier Foroperation at elevations above 4 500 feet equipment ratings shall be reduced at the rate of 4 percent for each 1 000 feet above 4 500 feet befo...

Страница 7: ...EBOX CHECK WITH YOUR LOCAL CODE FOR ALLOWABLE DISTANCES CODES Adhere to all local codes or in their absence the latest edition of The National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition which can be obtained from The American National Standards Institute Inc 1430 Broadway New York NY 10018 or National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 Seller of unvented propan...

Страница 8: ...____ volume of space ft3 50 ft3 Maximum BTU Hr the space can support Example 3072 ft3 50 ft3 61 44 or 61 440 BTU Hr the space can support 3 Add the BTU Hr of all the fuel burning appliances in the space Vent Free heater _______ BTU Hr Gas appliance 1 _______ BTU Hr Gas appliance 2 _______ BTU Hr Gas appliance 3 _______ BTU Hr Total _______ BTU Hr Example Vent free heater 1 9 000 BTU Hr Vent free h...

Страница 9: ...ne and not in conjunction with any type of combustible fire surround No combustible shelves should be positioned on the wall above the appliance It should be established that any mirrors or picture frames etc to be positioned on the wall above the appliance are able to withstand pro longed exposure to moderate heat and moisture before proceeding with their installation The wall must be structurall...

Страница 10: ...gainst corrosion Ideally factory finished protected pipe work and fittings should be used Joints should be kept to a minimum and compression fittings must not be used The pipe work installation must be tested for soundness before any protection is applied and or the pipe work and fittings are buried Remove the wall mounting plate from the back of the appliance firebox by removing the two retaining...

Страница 11: ... all times Failure to do so may result in the risk of a fire For full information refer to the instruction manual provided with the heater Note Zero clearance from bottom of heater frame required for hard combustible floors Minimum 4 clearance required to rugs or any fabric floor coverings REFER TO INSTRUCTION MANUAL IMPORTANT Fabrics curtains and drapes are not permited above the heater at any di...

Страница 12: ... wall and drill holes for the additional fixing points as required Insert either wall plugs or cavity screw fixings as required Re position the outer casing on the wall and using a bubble level to check the casing is square and level tighten all of the fixing screws fully Now with the outer casing fixed to the wall the main firebox can be secured in position The firebox is held on the outer casing...

Страница 13: ...upstream of the heater Figure 6 within the structure s piping system to prevent moisture and contaminants from passing through the pipe to the heater controls and burner Failure to do so could prevent the heater from operating reliably The heater gas inlet connection is 3 8 NPT at the regulator located below the burner in the right hand side of the heater When tightening up the joint to the regula...

Страница 14: ... periodic visual check of the pilot flame and the burner flame should be carried out The gap between the spark electrode and the pilot should be 1 8 to 3 16 to produce a good spark There should be no need to adjust this DO NOT ATTEMPT TO ADJUST THE GAP If under any circumstances the piezo electric spark fails the pilot cannot be lit manually Adjustment to the pilot is Not allowed 17 0 GAS PRESSURE...

Страница 15: ...ns are approved for use to clean glass Non ammonia based household cleaner 50 50 mix of white vinegar and water Gas fireplace stove glass cleaner PAINTED AREAS These can be cleaned using a dry cloth LIMESTONE SURFACES Remember that limestone is porous and therefore susceptible to marking in use The limestone frame may be cleaned with a small amount of warm soapy water Any stubborn stains may be re...

Страница 16: ...ge from the joints or gasket faces especially around the door It is important to note that the appliance can never be expect ed to be 100 smoke tight and small quantities of smoke may be seen in corners of joints and gasket faces etc without affecting safety when the fire is in operation Turn on the fireplace as per the operating instructions and run at maximum setting for 15 minutes Position gas ...

Страница 17: ...e pilot is located on the left side behind the burner Figure 11 The control knob is located on the lower right hand side of the outer case It is marked as shown in Figure 10 6 Depress control knob in and turn counterclockwise to the SPARK position Figure 10 and hold there for a few seconds Note If you are running the heater for the first time or after an extended period of non use it will be neces...

Страница 18: ...em with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY LIT Pilot flame shrinks when fire is on high Poor gas flow to fire check pressure with fire on high If pressure is low remove any restriction in pipe work or valve Check all pipe work are adequately...

Страница 19: ...NSTALACION DE CHIMENEAS DE PARED SIN SALIDA DE HUMOS IMPORTANT THIS APPLIANCE IS TO BE WALL HUNG ONLY DO NOT RECESS OR INSET ANY PART OF THE APPLIANCE THIS TEMPLATE IS FOR THE MARKING OF FIXING POINTS ONLY DO NOT INSTALL THE APPLIANCE WITH THIS TEMPLATE IN PLACE IMPORTANTE ESTE APARATO UNICAMENTE DEBE SER COLGADO EN UNA PARED NO EMPOTRE NINGUN ELEMENTO DE ESTE APARATO ESTA PLANTILLA SIRVE UNICAMEN...

Страница 20: ...is heater may result in property damage or personal injury Figure 13 Visual check for cor rect pilot flame Glass Door Removal Remove the four 4 screws indicated then lift door off Figure 12 4 off burner installation positions As our policy is one of continuous improvement and development we hope therefore you will understand we must retain the right to amend details and or specifications without p...

Страница 21: ...round 71 lb 6 15 cu ft Product Reference Information Cat No Model Ship Wt Ship Volume H7224 X FIRE WS NG 71 lb 6 07 cu ft H7225 X FIRE WS LP 71 lb 6 07 cu ft Surround Specifications 8 3 4 8 3 4 16 16 39 15 16 5 1 2 8 5 8 21 1 16 54 1 2 37 13 16 25 5 8 10 5 8 Note Limestone and Granite are natural products and therefore each piece will have its own unique character with no two pieces being quite th...

Страница 22: ...t 1 16 KEY D1 Distance from mounting surface to rear entry point D2 Distance from mounting surface to center of side entry point D3 Distance from mounting surface to regulator gas entry point D3 D1 D2 REGULATOR GAS ENTRY POINT D1 D3 D2 Finished Wall TOP VIEW Fireplace Regulator Gas Entry Point Model D1 D2 D3 X fires Widescreen 3 8 10mm 1 3 8 35mm 4 5 16 110mm GAS ENTRY POINT DIMENSIONS ...

Страница 23: ...23 NOTES ...

Страница 24: ...d through your Lennox distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any que...

Отзывы: