NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

5

Figure 6

Figure 5

INSTALLING THE FIREPLACE

Step 1. Slide the fireplace into prepared fram-
ing or position fireplace in its final position and
frame later.

The fireplace may not be recessed into a com-
bustible floor. Maintain the floor to hearth
clearance established by the fireplace lower
front face.

Step 2. Insert the provided metal safety strips,
beneath the fireplace as illustrated (

Figures 5, 6

and 7 ). The safety strips should overlap 

¹⁄₂

"

min. for continual coverage of the floor.

Air Inlet

The installation of the air inlet is required for
safe fireplace operation.

Step 1. Determine the location for air inlet,
which can be installed through an outside
wall.  A 6 1/2" diameter hole will be required
for installation of the air inlet assembly (

see

Figure 17 ).

CAUTION: AVOID INSTALLING THE AIR IN-
LET WHERE THE OPENING COULD BE
BLOCKED BY SNOW, BUSHES OR OTHER
OBSTACLES.  THE MAXIMUM HEIGHT FOR
THE OUTSIDE AIR IS 50 FEET ABOVE THE
HEARTH, PROVIDING THE AIR INLET IS TER-
MINATED A MINIMUM OF THREE (3) FEET
BELOW THE CHIMNEY CAP LEVEL.

Note:  Air inlet ducts must not terminate in
attic space.

CLEARANCES

Minimum clearance to combustibles for the
fireplace is as follows; sides and back – 

¹⁄₂

"

(13mm), combustible floor – 0" (0mm), adja-
cent wall 18" (457mm), adjacent shielded wall
(

K factor of .84 or less 40" W x 40" H ) 12"

(305mm), ceiling – 37 

¹⁄₂

" (953mm).  

Refer to

page 17 for more detail.

Figure 4

Metal Safety Strip

Floor

Hearth

Extension

¹⁄₂

" (13mm)

Maintain

¹⁄₂

" (13mm)

Air Space
at Sides
and Back

Combustible

Wall

Fireplace On Non-Combustible Floor

Metal Safety Strip

Floor

¹⁄₂

" (13mm)

Maintain

¹⁄₂

" (13mm)

Air Space
at Sides
and Back

Combustible

Wall

Platform

Hearth

Extension

Fireplace On Combustible Floor

Drain Connector

(see Detail A )

Seal All

Seams,

Joints

And

Corners

Around The

Bottom Of

Fireplace

Access
Drain Plug
Through
Air Inlet
Opening

Detail A

Threaded

Reducer

³⁄₄

” x 

¹⁄₂

(PVC)

Threaded
Elbow 

³⁄₄

@ 90

°

(PVC)

Step 2.  Locate the drainage plug and remove
it by depressing the locking tabs and pushing
down through the outside air opening at the
bottom of the fireplace.

Step 3.  On the exposed hole, install a PVC
threaded coupling reducer, 3/4" x 1/2" going
from inside of the fireplace out.  Apply a
silicone-based sealant around the base and
threads before installation.

Step 4.  Holding the reducer coupling with a
wrench, thread a 3/4", 90 degree, PVC elbow to
the reducer until it is tight to the metal.

Note:  To assure proper drainage, the fireplace
must be installed on a leveled surface.

Note:  Clearance at the nailing flange for both
fireplace models is 0" (0mm).

Note:  Adjacent wall considerations are for an
adjacent wall on only a single side.  Walls
should not be placed at minimum distance at
both sides of the fireplace.

Note:  The LSO-43 has been provided with a
drain plug under the fireplace by the air inlet
opening.  If the fireplace is on a platform or
wooden surface, a hole must be bored to make
room for an elbow connector.  If the fireplace is
on a concrete floor, it will be necessary to
elevate the appliance at least 1" high to permit
the installation of an elbow connector.

Step 1.  Seal all joints, gaps and corners around
the bottom of the fireplace before positioning
the fireplace on its location (

Figure 4 ).

3. Note the floor construction, i.e. 2 x 6’s, 2 x 8’s
or 2 x 10’s, single or double joists, type and
thickness of floor boards.

4. Use this information and consult your local
building code to determine if you need addi-
tional support.

If you plan to raise the fireplace and hearth
extension, build the platform assembly then
position fireplace and hearth extension on top.
Secure the platform to the floor to prevent
possible shifting.

WATERPROOFING THE FIREPLACE

Although the LSO-43 fireplace is designed to
drain to the front most of the water from rain
and other sources that may enter the hearth
area, condensation and unusual conditions
may cause water to collect inside the fire-
place bottom.

To prevent this, the builder must provide a
means to drain water from under the fire-
place by building or installing a water collec-
tor of the builder's choice, or installing a PVC
drain as follows:

Содержание LSO-43

Страница 1: ...nents under any circumstances Any modification or alteration of the fireplace system including but not limited to the fireplace chimney components and accessories may void the warranty listings and ap...

Страница 2: ...arwithcom monlyacceptedfireplaceinstallationandsafety techniques as well as prevailing local codes The most important areas of concern dealing with the installation of factory built fireplaces areclea...

Страница 3: ...lso be enclosed to prevent impact damage to the fireplace However the enclosure must now be finished on all four 4 sides The exterior of the enclosure may be finished in a textured plywood a wood clap...

Страница 4: ...wall mate rial surround and hearth extension to your individual taste 7 Assemble and attach optional glass door assembly Study the three dimensional illustration Fig ure 1 to get a general idea of ea...

Страница 5: ...emove it by depressing the locking tabs and pushing down through the outside air opening at the bottom of the fireplace Step 3 On the exposed hole install a PVC threaded coupling reducer 3 4 x 1 2 goi...

Страница 6: ...219mm 52 1327mm 39 1008mm 4 114mm Side View Left Top View 44 1133mm 12 316mm 39 1008mm 9 252mm 1 40mm 1 32mm Drain Plug 11 287mm Metal Safety Strips with 13mm Min Overlap 1 38mm The safety strips shou...

Страница 7: ...e Figure 14 Figure 15 Figure 13 Note All framing dimensions calculated for 1 2 dry wall at the fireplace face If sheathing the chaseorfinishingwithotherthicknessmaterials calculations will need to be...

Страница 8: ...oof from below to mark position Mark and cut a holeintheceiling aroundthenail Figure19 Then plumb from ceiling or roof directly above the cut hole to determine roof hole position Step 6 Route the Clas...

Страница 9: ...ure they engage properly Note For Canadian installations all chimney installedoutsidethebuildingmustbeconstructed with galvalume outer sections only effective January 1 1992 The appropriate model desi...

Страница 10: ...vertical position of the chimney and the 2 minimum air space to combustibles Figure 26 Note Do not caulk or seal the flashing at the chimney Step 6 Secure flashing by nailing along the perimeter into...

Страница 11: ...deter mine the number of chimney sections quan tity and length required Note It is recommended that all exterior ex posed metal chimney components such as ter minations flashings storm collars and or...

Страница 12: ...y be attached together or a section or sections of chimney may be used between but do not exceed 20 in total length between elbows If sections of pipe exceed 10 between elbows a chimney stabi lizer mu...

Страница 13: ...hes Feet Inches 12 18 36 MM M 461 38 5 0 1 13 11722 11 72 465 38 9 2 0 13 11824 11 82 471 39 3 1 1 13 11976 11 98 479 39 11 0 0 14 12179 12 18 489 40 9 1 0 14 12433 12 43 495 41 3 0 1 14 12586 12 59 4...

Страница 14: ...0 0 362 851 17 38 1 0 1 1 0 438 978 20 43 1 0 0 2 0 514 1111 21 45 1 0 0 0 1 533 1149 22 47 1 0 2 1 0 565 1207 25 52 1 0 1 2 0 641 1334 26 54 1 0 1 0 1 667 1378 28 57 1 0 0 3 0 718 1467 29 59 1 0 0 1...

Страница 15: ...TH AN UNVENTED GAS LOG SET TO REDUCE THE RISK OF FIRE OR INJURY DO NOT INSTALL AN UNVENTED GAS LOG SET INTO THIS FIREPLACE If you re installing a gas line connect it before the fireplace is framed and...

Страница 16: ...40 H wall shield constructed of a durable noncombustible material having an equal or better lower k value insulating value than k 84 BTU IN FT2 HR F At no time may a perpendicular side wall be located...

Страница 17: ...earest standard thickness available which is 1 2 If the hearth extension material s that is intended to be used is NOT listed on Table 1 the material can still be used if the material s is noncombusti...

Страница 18: ...e in the installation of this appliance Fireplace Information Model Catalog Number Weight LSO 43 H0303 270 lbs LSO 43 H H0304 270 lbs 18 457mm 45 Combustible Materials Allowed in Shaded Area 1 25mm 18...

Страница 19: ...Termination Square 63L49 FTF10 CT1 Firestop Spacer Flat 63L36 F10FS 2 Chase Termination Round 63L46 FTF10 CTDT Chase Termination Square 63L52 FTF10 CT2 Stabilizer 63L26 FTF10 S4 INSTALLATION COMPONENT...

Страница 20: ...ges at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S...

Отзывы: