NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

4

Figure 3

Figure 2

When choosing a location, care must be taken
to avoid places where flooding or running water
may be a problem.

Carefully consider the position of the fireplace
opening with respect to the location of adjacent
or nearby stairwells, doors, windows, walk-
ways and over hanging trees, patios and wires.

When locating the fireplace, consideration must
be given to combustibles and final finishing.
See 

Figure 3 and confine the final location of

combustible finish materials to the "Safe Zone".

DO NOT place furniture or other items such
as plants or decorative objects within 60" of
the fireplace front face.

Wall
Covering

Frame Surface Not
To Be Covered With
Combustible Materials

Safe

Zone

45

°

18”

Door

Opening

1

18”

LIVING SPACE

PATIO

Optional
Hearth
Extension

Air Inlet
(Inlet Must
Be Free Of Any
Obsutuctions)

CHIMNEY SYSTEM

These fireplaces are designed and code listed
for use with Security's FTF10 chimney System
only. Always use Security's FTF10 chimney
components with these fireplaces. Do not modify
or alter these components as this may cause a
potential serious hazard and void the Warranty.

Note: Do not insulate the chase cavity with
blown or fill type insulation materials.

Note: Local codes may not require firestops at
the ceiling levels for outside chase installa-
tions. However, it is recommended for safety
and the reduction of heat loss.

Chimney Height

The total height of your completed fireplace
system from the surface the fireplace rests
on to the chimney top must not exceed 80'
(24.4) and must also meet minimum height
requirements. Refer to the minimum system
height chart.

ASSEMBLY STEPS

Note: The following steps represent the normal
sequence of installation. Each installation is
unique, however, and might require a different
sequence.

1. Position firebox prior to framing or into
prepared framing.

2. Waterproof the fireplace (

see Waterproofing

The Fireplace on page 5 ).

3. Install the chimney system.

4. Install air inlet.

5. Plumb gas line if a decorative gas appliance
will be used. (Gas connections should only be
performed by an experienced, licensed/certi-
fied tradesman.)

6. Complete the installation, finish wall mate-
rial, surround and hearth extension to your
individual taste.

7. Assemble and attach optional glass door
assembly.

Study the three dimensional illustration (

Fig-

ure 1 ) to get a general idea of each element of
your fireplace system.

PRE-INSTALLATION NOTES

The fireplace may be installed directly on a
combustible floor or raised on a platform of an
appropriate height. Do not place the fireplace
on vinyl or other soft floor coverings. It may,
however, be placed on flat wood, plywood,
particle board or other hard surfaces.

Be sure the fireplace rests on a solid continu-
ous floor or platform with appropriate framing
for support.

The fireplace may be positioned and then the
framing built around it, or the framing may be
constructed and the fireplace positioned into
the opening.

Usually, no special floor support is needed for
the fireplace, however, to be certain:

1. Estimate the total weight of the fireplace
system including chimney and surround ma-
terials such as brick, stone, etc., to be in-
stalled.  Shipping weights for the fireplace may
be found on page 18.

2. Measure the square footage of the floor
space to be occupied by the system, surrounds
and hearth extensions.

LOCATION OF FIREPLACE

Carefully select the proper location for chimney
obstructions, clearance to side wall(s) air inlet
location and aesthetics. With proper pre-plan-
ning, a slight adjustment of a few inches can
save considerable time and expense later dur-
ing construction and assembly.  See 

Figure 2

for some examples.

*When the fireplace is installed anywhere closer
than 10 feet from any building or structure.

Minimum Height

The minimum height for a complete system is
10' 6" if installed with an FTF10-CT1 or FTF10-
CTDT terminations.  Any other termination
requires a 14' minimum system height.

Free Standing Installation

The system height may be reduced to a single
length of FCTF10-36 pipe and termination
(minimum 7' 8") with either the FTF10-CTD or
FTF10-CT1.  The fireplace must be installed as
a free standing system and located a minimum
of 10' away from any building or structure
(

refer to Figure 1 ).

ASSEMBLY OUTLINE
Before You Start

Check your inventory list to be sure you have all
the necessary parts supplied in good usable
condition. Check also for any concealed damage.

MINIMUM SYSTEM HEIGHT

 Security's FTF10 Pipe

Vertical

10' 6"

*

Installation

( 3.2 m)

One

14'

Offset

( 4.3 m)

Two

22'

Offsets

( 6.7 m)

Содержание LSO-43

Страница 1: ...nents under any circumstances Any modification or alteration of the fireplace system including but not limited to the fireplace chimney components and accessories may void the warranty listings and ap...

Страница 2: ...arwithcom monlyacceptedfireplaceinstallationandsafety techniques as well as prevailing local codes The most important areas of concern dealing with the installation of factory built fireplaces areclea...

Страница 3: ...lso be enclosed to prevent impact damage to the fireplace However the enclosure must now be finished on all four 4 sides The exterior of the enclosure may be finished in a textured plywood a wood clap...

Страница 4: ...wall mate rial surround and hearth extension to your individual taste 7 Assemble and attach optional glass door assembly Study the three dimensional illustration Fig ure 1 to get a general idea of ea...

Страница 5: ...emove it by depressing the locking tabs and pushing down through the outside air opening at the bottom of the fireplace Step 3 On the exposed hole install a PVC threaded coupling reducer 3 4 x 1 2 goi...

Страница 6: ...219mm 52 1327mm 39 1008mm 4 114mm Side View Left Top View 44 1133mm 12 316mm 39 1008mm 9 252mm 1 40mm 1 32mm Drain Plug 11 287mm Metal Safety Strips with 13mm Min Overlap 1 38mm The safety strips shou...

Страница 7: ...e Figure 14 Figure 15 Figure 13 Note All framing dimensions calculated for 1 2 dry wall at the fireplace face If sheathing the chaseorfinishingwithotherthicknessmaterials calculations will need to be...

Страница 8: ...oof from below to mark position Mark and cut a holeintheceiling aroundthenail Figure19 Then plumb from ceiling or roof directly above the cut hole to determine roof hole position Step 6 Route the Clas...

Страница 9: ...ure they engage properly Note For Canadian installations all chimney installedoutsidethebuildingmustbeconstructed with galvalume outer sections only effective January 1 1992 The appropriate model desi...

Страница 10: ...vertical position of the chimney and the 2 minimum air space to combustibles Figure 26 Note Do not caulk or seal the flashing at the chimney Step 6 Secure flashing by nailing along the perimeter into...

Страница 11: ...deter mine the number of chimney sections quan tity and length required Note It is recommended that all exterior ex posed metal chimney components such as ter minations flashings storm collars and or...

Страница 12: ...y be attached together or a section or sections of chimney may be used between but do not exceed 20 in total length between elbows If sections of pipe exceed 10 between elbows a chimney stabi lizer mu...

Страница 13: ...hes Feet Inches 12 18 36 MM M 461 38 5 0 1 13 11722 11 72 465 38 9 2 0 13 11824 11 82 471 39 3 1 1 13 11976 11 98 479 39 11 0 0 14 12179 12 18 489 40 9 1 0 14 12433 12 43 495 41 3 0 1 14 12586 12 59 4...

Страница 14: ...0 0 362 851 17 38 1 0 1 1 0 438 978 20 43 1 0 0 2 0 514 1111 21 45 1 0 0 0 1 533 1149 22 47 1 0 2 1 0 565 1207 25 52 1 0 1 2 0 641 1334 26 54 1 0 1 0 1 667 1378 28 57 1 0 0 3 0 718 1467 29 59 1 0 0 1...

Страница 15: ...TH AN UNVENTED GAS LOG SET TO REDUCE THE RISK OF FIRE OR INJURY DO NOT INSTALL AN UNVENTED GAS LOG SET INTO THIS FIREPLACE If you re installing a gas line connect it before the fireplace is framed and...

Страница 16: ...40 H wall shield constructed of a durable noncombustible material having an equal or better lower k value insulating value than k 84 BTU IN FT2 HR F At no time may a perpendicular side wall be located...

Страница 17: ...earest standard thickness available which is 1 2 If the hearth extension material s that is intended to be used is NOT listed on Table 1 the material can still be used if the material s is noncombusti...

Страница 18: ...e in the installation of this appliance Fireplace Information Model Catalog Number Weight LSO 43 H0303 270 lbs LSO 43 H H0304 270 lbs 18 457mm 45 Combustible Materials Allowed in Shaded Area 1 25mm 18...

Страница 19: ...Termination Square 63L49 FTF10 CT1 Firestop Spacer Flat 63L36 F10FS 2 Chase Termination Round 63L46 FTF10 CTDT Chase Termination Square 63L52 FTF10 CT2 Stabilizer 63L26 FTF10 S4 INSTALLATION COMPONENT...

Страница 20: ...ges at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S...

Отзывы: