Lennox Hearth Products LSO-43 Скачать руководство пользователя страница 1

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

1

43" Wood Burning Outdoor Fireplace
P/N  850,015M  REV.  C  03/2007

LSO-43

LSO-43-H

MODELS

RETAIN THESE INSTRUCTIONS

FOR FUTURE REFERENCE

OASIS SERIES

This installation manual will enable you to obtain a safe, efficient and
dependable installation of your fireplace system. Please read and under-
stand these instructions before beginning your installation.

Do not alter or modify the fireplace or its components under any
circumstances. Any modification or alteration of the fireplace system,
including but not limited to the fireplace, chimney components and
accessories, may void the warranty, listings and approvals of this system
and could result in an unsafe and potentially dangerous installation.

IMPORTANT! TO ASSURE PROPER ALIGNMENT OF GLASS DOORS:
INSTALL THIS FIREPLACE IN A SQUARE AND PLUMB CONDITION,
USING SHIMS AS NECESSARY AT SIDES AND/OR BOTTOM.

Note: This fireplace has only been listed and approved for use out of
doors.  Significant cold air infiltration will result if installed indoors.

INSTALLATION
INSTRUCTIONS

OTL Report No. 116-F-01-2

Содержание LSO-43

Страница 1: ...nents under any circumstances Any modification or alteration of the fireplace system including but not limited to the fireplace chimney components and accessories may void the warranty listings and ap...

Страница 2: ...arwithcom monlyacceptedfireplaceinstallationandsafety techniques as well as prevailing local codes The most important areas of concern dealing with the installation of factory built fireplaces areclea...

Страница 3: ...lso be enclosed to prevent impact damage to the fireplace However the enclosure must now be finished on all four 4 sides The exterior of the enclosure may be finished in a textured plywood a wood clap...

Страница 4: ...wall mate rial surround and hearth extension to your individual taste 7 Assemble and attach optional glass door assembly Study the three dimensional illustration Fig ure 1 to get a general idea of ea...

Страница 5: ...emove it by depressing the locking tabs and pushing down through the outside air opening at the bottom of the fireplace Step 3 On the exposed hole install a PVC threaded coupling reducer 3 4 x 1 2 goi...

Страница 6: ...219mm 52 1327mm 39 1008mm 4 114mm Side View Left Top View 44 1133mm 12 316mm 39 1008mm 9 252mm 1 40mm 1 32mm Drain Plug 11 287mm Metal Safety Strips with 13mm Min Overlap 1 38mm The safety strips shou...

Страница 7: ...e Figure 14 Figure 15 Figure 13 Note All framing dimensions calculated for 1 2 dry wall at the fireplace face If sheathing the chaseorfinishingwithotherthicknessmaterials calculations will need to be...

Страница 8: ...oof from below to mark position Mark and cut a holeintheceiling aroundthenail Figure19 Then plumb from ceiling or roof directly above the cut hole to determine roof hole position Step 6 Route the Clas...

Страница 9: ...ure they engage properly Note For Canadian installations all chimney installedoutsidethebuildingmustbeconstructed with galvalume outer sections only effective January 1 1992 The appropriate model desi...

Страница 10: ...vertical position of the chimney and the 2 minimum air space to combustibles Figure 26 Note Do not caulk or seal the flashing at the chimney Step 6 Secure flashing by nailing along the perimeter into...

Страница 11: ...deter mine the number of chimney sections quan tity and length required Note It is recommended that all exterior ex posed metal chimney components such as ter minations flashings storm collars and or...

Страница 12: ...y be attached together or a section or sections of chimney may be used between but do not exceed 20 in total length between elbows If sections of pipe exceed 10 between elbows a chimney stabi lizer mu...

Страница 13: ...hes Feet Inches 12 18 36 MM M 461 38 5 0 1 13 11722 11 72 465 38 9 2 0 13 11824 11 82 471 39 3 1 1 13 11976 11 98 479 39 11 0 0 14 12179 12 18 489 40 9 1 0 14 12433 12 43 495 41 3 0 1 14 12586 12 59 4...

Страница 14: ...0 0 362 851 17 38 1 0 1 1 0 438 978 20 43 1 0 0 2 0 514 1111 21 45 1 0 0 0 1 533 1149 22 47 1 0 2 1 0 565 1207 25 52 1 0 1 2 0 641 1334 26 54 1 0 1 0 1 667 1378 28 57 1 0 0 3 0 718 1467 29 59 1 0 0 1...

Страница 15: ...TH AN UNVENTED GAS LOG SET TO REDUCE THE RISK OF FIRE OR INJURY DO NOT INSTALL AN UNVENTED GAS LOG SET INTO THIS FIREPLACE If you re installing a gas line connect it before the fireplace is framed and...

Страница 16: ...40 H wall shield constructed of a durable noncombustible material having an equal or better lower k value insulating value than k 84 BTU IN FT2 HR F At no time may a perpendicular side wall be located...

Страница 17: ...earest standard thickness available which is 1 2 If the hearth extension material s that is intended to be used is NOT listed on Table 1 the material can still be used if the material s is noncombusti...

Страница 18: ...e in the installation of this appliance Fireplace Information Model Catalog Number Weight LSO 43 H0303 270 lbs LSO 43 H H0304 270 lbs 18 457mm 45 Combustible Materials Allowed in Shaded Area 1 25mm 18...

Страница 19: ...Termination Square 63L49 FTF10 CT1 Firestop Spacer Flat 63L36 F10FS 2 Chase Termination Round 63L46 FTF10 CTDT Chase Termination Square 63L52 FTF10 CT2 Stabilizer 63L26 FTF10 S4 INSTALLATION COMPONENT...

Страница 20: ...ges at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S...

Отзывы: