background image

8

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Facing & 

Mantel - 

Side View

f

aCing

 

and

 m

antel

 C

learanCes

Note: Hearth protection to be min. /8” (10mm) thick non-
combustible or equivalent, with a k factor of .84.

i

nsert

 l

eveling

At each front and rear corner of the insert is an adjustable leg 

provided to level the insert should the hearth of the fireplace 

be uneven. To adjust the legs, loosen the two 5/32" allen head 

screws, move the leg to the desired height, and then tighten 

the screws. Repeat these steps for each adjusting leg.

G

13”(330mm)

10”(254mm)

0”(0mm)

H

0”(0mm)

2”(21mm)

4”(102mm)

E

H

F

G

J

CL

MANTEL

TRIM

Mantel

Trim

Hearth / Floor Protection

E  =  31-1/2"  (800mm)  from  Top  Facing  to  Bottom  of 

Insert

F  =  25-1/2” (648mm) from Center of Glass to Side Facing 

or Side Wall

J  =  39” (991mm) from 10.5” (267mm) Mantel to Bottom 

of Insert

h

earth

 p

roteCtion

G =   Minimum Hearth Protection from Front of Insert*

H =  Vertical Distance from Insert Bottom to Combustible 

Material.

Clearances to Combustibles

m

inimum

 C

learanCes

 

to

 C

ombustibles

3"/76mm

3"/76mm

3"/76mm

1-1/2”

38mm

31-1/2”

800mm

33-1/2”

851mm

36-1/2”

927mm

39-1/2”

1003mm

C

learanCes

Figure 4

Figure 5

Содержание Direct-Vent Gas

Страница 1: ...lez le service des incendies L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz WARNING If the information in this man...

Страница 2: ...lation 10 Surround Panels Installation 11 Face Installation 11 Gas Line Installation 12 Gas Pressure Requirements 12 LP Natural Gas Supplies 12 Air Shutter Adjustment 12 13 Operating Instructions 13 1...

Страница 3: ...bsence of local codes with the National Electrical Code ANSI NFPA 70 latest edition In Canada the current CSA C22 1 Canadian Electrical Code latest edition Your Lennox gas insert must be equipped for...

Страница 4: ...ucture Combustionairisdrawnfromoutside the structure When installing in a factory built fireplace the fireplace grate must be removed and the damper must be removed or secured open WARNING THIS FIREPL...

Страница 5: ...The individual manual shut off must be a T handle type valve Commonwealth Of Massachusetts Requirements Note The following requirements reference various Massachusetts and national codes not contained...

Страница 6: ...ired Insert Body Packaging List 1 Insert Body with Burner Cassette 1 Log Set 1 Bag of Embers 1 Fasteners 6 slotted 1 4 truss screws 6 speed nuts 9 spring clips 3 plastic adhesive wire restraints 1 Ins...

Страница 7: ...ortionofthechimneysystemshowssigns of structural or mechanical weaknesses such as cracks leaky joints corroded or warped surfaces the faulty portion must be repaired or replaced prior to installing th...

Страница 8: ...n the screws Repeat these steps for each adjusting leg G 13 330mm 10 254mm 0 0mm H 0 0mm 2 21mm 4 102mm E H F G J C L MANTEL TRIM Mantel Trim Hearth Floor Protection E 31 1 2 800mm from Top Facing to...

Страница 9: ...1installationcode Theinsertmustnotbeconnected to a chimney flue serving a separate solid fuel burning ap pliance This gas insert requires a 3 diameter listed flex liner The vent should terminate with...

Страница 10: ...the flue collar is removable see Flue Collar Connection If the factory built fireplace has no gas access hole s pro vided an access hole of 1 1 2 37 5 mm or less may be drilled through the lower sides...

Страница 11: ...ure loosely Face Installation The faces come with hooked brackets To install the face hang the hooked brackets on the surround brackets C in Figure 12 Figure 12 A B C Spring Handle Latches Door Mounti...

Страница 12: ...lve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig The appliance must be isolated from the gas supply piping...

Страница 13: ...ghting the pilot follow these instructions exactly B BEFORE LIGHTING smell around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on...

Страница 14: ...knob slightly and turn clockwise to OFF Do not force This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air WARNIN...

Страница 15: ...When the blower turns on the sound of rushing air may be heard The blower sounds may be reduced by adjusting the speed control located on the blower assembly Also a slight clicking sound may be heard...

Страница 16: ...e to determine the proper gage of wire for the thermostat or wall switch connections This table refers to the total length of the wire out to the switch and back The thermostat must be a millivolt typ...

Страница 17: ...le and extend across the main burner ports Be careful not to back the screw out of its threads Replace the cover and check for gas leaks using a gas leak test solution oCheck that the area around the...

Страница 18: ...reference Remove the insert face glass door and log set All of these items are fragile so handle them with care Next remove the nine allen head screws around the outside of the panel fastened to the b...

Страница 19: ...pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap between electrode and pilot should...

Страница 20: ...e Main Burner LP 53 H5951 Orifice High Altitude Main Burner LP 54 H5464 Conversion Kit NG to LP H5465 Conversion Kit LP to NG H6013 Blower w Mounting Bracket H5875 Blower Snap Switch H5655 Blower Spee...

Страница 21: ...ase de H l appareil aux combustibles HOMOLOGU FOYER RADIANT PR FABRIQU AU GAZ INSERTION DE FOYER AU GAZ NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE TEST SELON LA NORME ANSI Z21 88 2005 CSA 2 33 2005 FO...

Страница 22: ...un agent de service ou un fournisseur de gaz Si vous op rez cet appareil sans qu il ne soit correctement raccord un conduit d vacuation vous pourriez risquer d tre empoisonn au monoxyde de carbone CO...

Страница 23: ...on about your fireplace Please contact your Lennox Hearth Products dealer for any questions or concerns For the number of your nearest Lennox Hearth Products dealer please call 877 247 3673 Replacemen...

Страница 24: ...2007 Lennox reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor fo...

Отзывы: