background image

8

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

Insert the wall mounting screws into the top wall plugs, taking 

care to leave the screws protruding approximately 3/8” from the 

wall. Now hang the appliance onto these screws through the two 

keyhole shaped holes in the back panel of the appliance. 

Insert  the  lower  mounting  screws  into  the  lower  wall  plugs 

through the corresponding depressed holes in the lower part of 

the back panel. Do not tighten fully.

Before tightening the wall mounting screws fully, at this stage 

it  is  recommended  to  check  the  horizontal  alignment  of  the 

appliance with a bubble level, as small adjustments can still be 

made if necessary. When this has been checked, tighten all four 

fixing screws fully.

To access the upper fixing screws insert a screwdriver through 

the holes in the deflector plates above the catalyst as shown in 

Figure 3

.

11.0 CHECKING THE BURNER

There  are  no  imitation  fuel  bed  components  to  install.  The 

appliance features a ribbon burner which is designed to produce 

a continuous band of flame over its length. The burner should be 

visually inspected to ensure it is free from any foreign matter. If 

it is necessary to clean or dust off the burner then the glass door 

should be removed by removal of the four retaining screws. Re-

fit the glass door after cleaning or inspection, ensuring a good 

seal.

1.0 CONNECTING A GAS LINE

10.0 MOUNTING THE APPLIANCE - continued

Figure 3

A qualified gas appliance installer must connect the gas room 

heater to the gas supply. Consult all local codes. 

The  installer  must  provide  an  ANSI  approved  manual  shut  off 

valve, flex connector and 3/8" NPT fitting. 

Route  gas  line  using  techniques  and  materials  prescribed  by 

local and/or national codes. Only use pipe of 1/2" or greater size 

to  allow  full  gas  volume  to  the  gas  fireplace.  Undue  pressure 

loss will occur if the pipe is too small. 

Regulator

Manual 

Shut-Off

Valve

Union

Sediment

Trap

Fireplace or

Firebox Wall

Wall

Shut-Off

Key

Fireplace or

Firebox Wall

Down

3"

Figure 4

An  ANSI  approved  manual  shut-off  valve  and  union  must  be 

installed  upstream  of  the  heater  within  the  fireplace  cavity 

when rigid pipe is used. Ensure that a sediment trap is installed 

upstream of the heater 

(Figure 4)

 within the structure’s piping 

system  to  prevent  moisture  and  contaminants  from  passing 

through the pipe to the heater controls and burner. Failure to do 

so could prevent the heater from operating reliably.

The  heater  gas  inlet  connection  is  3/8”  NPT  at  the  regulator, 

located below the burner, in the right hand side of the heater. 

When tightening up the joint to the regulator hold the regulator 

securely with a wrench to prevent the regulator from moving.

      IMPORTANT 

Hold heater regulator with a wrench to prevent move-

ment when connecting to inlet piping.

Содержание Catalytic Vent-Free Wall Mounted Gas FirePlace

Страница 1: ...om as appliance Due to high temperatures the appliance should be located out of traffic and away from furniture or draperies Do not place clothing or other materials on or near this appliance Improper...

Страница 2: ...control which has been under water InputratingsareshowninBTUperhourandareforelevations up to 4 500 feet Do not install this heater at an elevation above 4 500 feet if the gas supply has not been derat...

Страница 3: ...0 0 Mounting The Appliance 7 11 0 Checking The Burner 8 12 0 Connecting A Gas Line 8 13 0 Checking The Gas Connections 9 14 0 Gas Pressure Check 9 15 0 Spark Gap 10 16 0 Assembly of the Glass Facia 10...

Страница 4: ...ce with 248 CMR LPG appliances shall be subject to the storage requirements in accordance with 527 CMR 6 00 Portable unvented or natural gas fired space room heaters shall be prohibited e Unventednatu...

Страница 5: ...grills between rooms Example 24 L x 16 W x 8 H 3072 ft3 2 Dividethevolumeofspaceby50ft3 todeterminethemaximumBTU Hr the space can support ______ volume of space ft3 50 ft3 Maximum BTU Hr the space ca...

Страница 6: ...exposed to moderate heat should be considered as a combustible material or surface Clearance to the sides of the appliance are 4 but curtains drapes and other fabrics are not permitted within a distan...

Страница 7: ...otected againstcorrosion Ideallyfactoryfinishedprotectedpipe workandfittings should be used Joints should be kept to a minimum and compression fittings must not be used The pipe work installation must...

Страница 8: ...glass door after cleaning or inspection ensuring a good seal 12 0 CONNECTING A GAS LINE 10 0 MOUNTING THE APPLIANCE continued Figure 3 A qualified gas appliance installer must connect the gas room hea...

Страница 9: ...The heater regulator controls the burner pressure which should be checked at the pressure test points located on the control valve itself shown in Figure 7 for burner manifold and regulator inlet sett...

Страница 10: ...face down on a soft surface Identify the top and bottom of the glass facia by observing the orientation of the keyhole shaped slots in the facia fixing brackets as shown in Figure 10 2 Slide on the s...

Страница 11: ...ox as shown Insert the M6 retain ing screws in the sides of the firebox and ensure they are unscrewed approximately 1 8 so the keyhole shaped holes may engage and the sides can be hooked on Note Front...

Страница 12: ...1 0 SERVICING THE BURNER WARNING Any change to this heater or its controls can be dangerous First remove the front Glass facia as described in Section 17 0 only in reverse remove the valve cover 4 scr...

Страница 13: ...t or match introduced at the base of the fire underneath the burner tray Large quantities of smoke will emerge from the top of the appliance but none should emerge from the joints or gasket faces espe...

Страница 14: ...side behind the burner Figure 20 7 Depress control knob in and turn counter clockwise to the SPARK position Figure 19 and hold there for a few seconds Note If you are running the heater for the first...

Страница 15: ...e or on the lint gauze clean thoroughly If the pilot will not stay lit there is a problem with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a seri...

Страница 16: ...WARNING Failuretopositionthepartsinaccordancewiththesediagramsorfailuretouseonlypartsspecificallyapproved with this heater may result in property damage or personal injury Visual check for correct pil...

Страница 17: ...17 30 0 NOTES...

Страница 18: ...2 2007 Lennox reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor...

Отзывы: