background image

3

.0 GENERAL INFORMATION

This appliance is a high efficiency, unvented, flame effect gas heater.  

It provides radiant and convected warmth both efficiently and safely 

utilizing the latest type catalytic convertor burner technology. The 

appliance does not require a flue system of any type as the catalytic 

converter cleans the flue products to provide a complete combustion 

system, which is intrinsically safe.

3.0 PACKAGING LIST

Quantity       Description

 

    1 

     Firebox And Burner Assembly

     1  

     Installation And Operation Instructions

     1 

     Glass Facia Panel Assembly

   1 

     Fitting Template

   1 

     Screw And Wall Plug Pack

   1 

     Rubber Grommet 

4.0 APPLIANCE SPECIFICATIONS

CONGRATULATIONS ON THE PURCHASE OF YOUR NEW 

GAS APPLIANCE MANUFACTURED BY LENNOX HEARTH 

PRODUCTS.

When you purchased your new gas fireplace, you joined the ranks of 

thousands  of  individuals  whose  answer  to  their  home  heating  needs 

reflects  their  concern  for  efficiency  and  our  environment.  We  extend 

our continued support to help you achieve the maximum benefit and 

enjoyment available from your new gas fireplace. It is our goal at Lennox 

Hearth Products to provide you, our valued customer, with an appliance 

that will ensure years of trouble-free warmth and pleasure. 
Thank you for selecting a Lennox Hearth Products gas fireplace as the 

answer to your supplemental home heating needs.
Sincerely, All of us at Lennox Hearth Products

TABLE OF CONTENTS

Section  Contents       

                        Page No.

  1.0 

Safety And Warning Information . . . . . . . . . . . . .  2

  2.0 

General Information . . . . . . . . . . . . . . . . . . . . . . .  3

  3.0 

Packaging List . . . . . . . . . . . . . . . . . . . . . . . . . . .  3

  4.0 

Appliance Specifications . . . . . . . . . . . . . . . . . . .  3

  5.0 

Burn-in Period . . . . . . . . . . . . . . . . . . . . . . . . . . .  4

  6.0 

Codes, Massachusetts & New York . . . . . . . . . . .  4

  7.0 

Combustion And Ventilation Air. . . . . . . . . . . . . .  5

  8.0 

Site Requirements . . . . . . . . . . . . . . . . . . . . . . . .  6

  9.0 

Preparing The Appliance . . . . . . . . . . . . . . . . . . .  6

  10.0  Mounting The Appliance . . . . . . . . . . . . . . . . . . .  7 

  11.0  Checking The Burner . . . . . . . . . . . . . . . . . . . . . .  8

  12.0  Connecting A Gas Line  . . . . . . . . . . . . . . . . . . . .  8

  13.0  Checking The Gas Connections . . . . . . . . . . . . . .  9

  14.0  Gas Pressure Check . . . . . . . . . . . . . . . . . . . . . . .  9 

  15.0  Spark Gap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10

  16.0  Assembly of the Glass Facia  . . . . . . . . . . . . . . . .  10 

  17.0  Fitting the Glass Facia . . . . . . . . . . . . . . . . . . . . .  11 

  18.0  Fitting the side panels . . . . . . . . . . . . . . . . . . . . .  11

  19.0  Briefing The Customer. . . . . . . . . . . . . . . . . . . . .  12

  20.0  Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12

  21.0  Servicing The Burner. . . . . . . . . . . . . . . . . . . . . .  12

  22.0  Pilot Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . .  12

  23.0  Catalysts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13

  24.0  Testing For Firebox Leakage  . . . . . . . . . . . . . . . .  13

  25.0  Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13

  26.0  Lighting Instructions & Turning Off Appliance . . .  14

  27.0  Troubleshooting Guide. . . . . . . . . . . . . . . . . . . . .  15

  28.0  Replacement Parts List . . . . . . . . . . . . . . . . . . . .  15 

  29.0  Positioning Of Field Assembled Parts . . . . . . . . .  16

  30.0  Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  17

  31.0  Product Reference Information . . . . . . . . . . . . . .  18

These heaters are fitted with a specially designed pilot utilizing an 

oxygen depletion sensor (ODS) which responds to the amount of 

oxygen available in the room and shuts the heater off before the oxygen 

level drops below 18%. The pilot can be relit only when fresh air is 

available. Refer to the 

Combustion and Ventilation Air

 section.

The appliance is designed to fit various types of situations as listed 

in the installation requirements.  

This appliance is factory set for operation on the gas type, and at the 

pressure stated on the appliance rating plate.

Read all these instructions before commencing installation. All instruc-

tions must be handed to the user for safekeeping.

Gas Type

Natural Gas

Gas inlet pressure

 

Max.

 

Min.

10.5” w.c.

6” w.c.

Regulator Pressure Setting

5” w.c.

Max Energy Input

11,950 BTU/hour

Min Energy Input

6,80 BTU/hour

Pilot Energy Input

560 BTU/hour

Burner Pressure

 

High

(Manifold)

 

Low

.4” w.c. 

0.8” w.c. 

Main burner flow restrictor

(burner orifice)

.0 mm (0.079”)

Oxypilot

SIT/Bray 908

Gas Inlet Connection

3/8” NPT at regulator

Ignition

Piezo spark

Spark Gap

1/8” - 3/16”

Please see Data Plate affixed to appliance for current data. This appliance is for use 

only with the gas type, and at the pressure stated on the appliance Data Plate.

Table 1

Содержание Catalytic Vent-Free Wall Mounted Gas FirePlace

Страница 1: ...om as appliance Due to high temperatures the appliance should be located out of traffic and away from furniture or draperies Do not place clothing or other materials on or near this appliance Improper...

Страница 2: ...control which has been under water InputratingsareshowninBTUperhourandareforelevations up to 4 500 feet Do not install this heater at an elevation above 4 500 feet if the gas supply has not been derat...

Страница 3: ...0 0 Mounting The Appliance 7 11 0 Checking The Burner 8 12 0 Connecting A Gas Line 8 13 0 Checking The Gas Connections 9 14 0 Gas Pressure Check 9 15 0 Spark Gap 10 16 0 Assembly of the Glass Facia 10...

Страница 4: ...ce with 248 CMR LPG appliances shall be subject to the storage requirements in accordance with 527 CMR 6 00 Portable unvented or natural gas fired space room heaters shall be prohibited e Unventednatu...

Страница 5: ...grills between rooms Example 24 L x 16 W x 8 H 3072 ft3 2 Dividethevolumeofspaceby50ft3 todeterminethemaximumBTU Hr the space can support ______ volume of space ft3 50 ft3 Maximum BTU Hr the space ca...

Страница 6: ...exposed to moderate heat should be considered as a combustible material or surface Clearance to the sides of the appliance are 4 but curtains drapes and other fabrics are not permitted within a distan...

Страница 7: ...otected againstcorrosion Ideallyfactoryfinishedprotectedpipe workandfittings should be used Joints should be kept to a minimum and compression fittings must not be used The pipe work installation must...

Страница 8: ...glass door after cleaning or inspection ensuring a good seal 12 0 CONNECTING A GAS LINE 10 0 MOUNTING THE APPLIANCE continued Figure 3 A qualified gas appliance installer must connect the gas room hea...

Страница 9: ...The heater regulator controls the burner pressure which should be checked at the pressure test points located on the control valve itself shown in Figure 7 for burner manifold and regulator inlet sett...

Страница 10: ...face down on a soft surface Identify the top and bottom of the glass facia by observing the orientation of the keyhole shaped slots in the facia fixing brackets as shown in Figure 10 2 Slide on the s...

Страница 11: ...ox as shown Insert the M6 retain ing screws in the sides of the firebox and ensure they are unscrewed approximately 1 8 so the keyhole shaped holes may engage and the sides can be hooked on Note Front...

Страница 12: ...1 0 SERVICING THE BURNER WARNING Any change to this heater or its controls can be dangerous First remove the front Glass facia as described in Section 17 0 only in reverse remove the valve cover 4 scr...

Страница 13: ...t or match introduced at the base of the fire underneath the burner tray Large quantities of smoke will emerge from the top of the appliance but none should emerge from the joints or gasket faces espe...

Страница 14: ...side behind the burner Figure 20 7 Depress control knob in and turn counter clockwise to the SPARK position Figure 19 and hold there for a few seconds Note If you are running the heater for the first...

Страница 15: ...e or on the lint gauze clean thoroughly If the pilot will not stay lit there is a problem with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a seri...

Страница 16: ...WARNING Failuretopositionthepartsinaccordancewiththesediagramsorfailuretouseonlypartsspecificallyapproved with this heater may result in property damage or personal injury Visual check for correct pil...

Страница 17: ...17 30 0 NOTES...

Страница 18: ...2 2007 Lennox reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor...

Отзывы: