INSTALLATION
PAGE 8
AIR INTAKE COVER
The pedestal is equipped with an air intake cover (lo-
cated at the top front of the pedestal). The air intake
cover should be adjusted to the open position if outside
combustion air is NOT provided. If outside combustion
air is provided, adjust to the closed position (see illustra-
tion to the right).
OUTSIDE AIR
In all manufactured (mobile) homes and in many site
built residences (subject to local code), a stove may be
required to use outside air for combustion. A 5 ¼” (133
mm) square outside air floor duct is available through
your dealer.
This stove can take in outside air directly through the
base. This type installation requires a hole through the
floor protector and the use of outside air floor duct (cata-
log # 14M67) to penetrate into the air space below the
home. When outside air is hooked up, the Air Intake
Cover must be adjusted to the closed position (see
Air
Intake Cover
section on this page).
NOTE:
Because the base sits 1” (25.4 mm) off the floor,
the outside air floor duct can be positioned along the
front to rear center line under the pedestal, but as close
to the opening in the base as location permits. The air
duct opening must be protected from any possible ob-
struction including loose floor insulation.
MANUFACTURED (MOBILE) HOME REQUIREMENTS
This stove is certified as a Room Heater, Solid Fuel Type
and may be used in Manufactured Housing providing the
following requirements are followed:
•
An outside air inlet must be provided for combustion
and be unrestricted while unit is in use.
•
WARNING: DO NOT INSTALL IN SLEEPING
ROOM.
•
Regulations require that the appliance must be se-
cured to the floor and grounded to the chassis. See
Securing the Stove to the Floor (and) Grounding
Stove.
•
Required venting is 6” (152 mm) diameter Type L-
Vent connector pipe with listed factory-built 103HT
chimney suitable for use with solid fuels or a code
approved masonry chimney. Approved brands of fac-
tory built chimney are listed in this manual. A rain
cap and spark arrestor is required (
see Clearances,
pages 6 & 7).
•
CAUTION: THE STRUCTURAL INTEGRITY OF
THE MOBILE HOME FLOOR, WALL, AND CEIL-
ING/ROOF MUST BE MAINTAINED.
•
The chimney must provide for a section joint so that
any parts extending above 13’ 6” (411 cm) from
ground level can be removed for transportation of the
mobile dwelling.
Air Intake
Cover
Open
Closed
Pedestal
Front
Floor Protector
Stove
Outside
Air Floor
Duct