460989001B
Specifications
Note:
For UL installations, refer to section UL Listed Installations.
The LNL-1300-U is for connection to low voltage, class 2 power-limited
circuits only. These specifications are subject to change without notice.
•
Primary power:
-
12 to 24 VDC + 10%
-
12 VDC @ 700 mA (includes reader current) nominal
-
24 VDC@ 350 mA (includes reader current) nominal
-
28.7 BTU/hour
•
Outputs: Form-C contacts: Relay 1 and 2 (K1 and K2): 5 A @ 30
VDC
•
Inputs:
-
Two (2) supervised, End of Line resistors, 1k/1k ohm, 1% 1/4
watt standard
-
One (1) unsupervised, dedicated for external (cabinet) tamper
•
Reader Interface:
-
Reader power: voltage 12 VDC +/-10% (optional 5 VDC +/-5%
jumper selectable, current 400 mA maximum to 50°C, derate to
300 mA for 70°C)
-
Reader LED output: open collector type switching (sinking) 10
mA each
-
Buzzer output: open collector type switching (sinking) 10 mA
each
-
Reader data inputs: 2-wire RS-485, Wiegand, Clock and Data
•
Communication: RS-485, 2-wire. 2400 to 38400 bps
•
Cable requirements:
-
Power: 18 AWG, 1 stranded twisted pair
-
RS-485 24 AWG, 120 ohm impedance, stranded twisted pair
with shield, 4000 feet (1219 m) maximum
-
Alarm Inputs: 1 stranded twisted pair per input, 30 ohms
maximum
-
Outputs: As required for the load
-
Reader data (Wiegand, Clock and Data): 18 AWG stranded, 6
conductor, 500 feet (150 m) maximum
-
Reader data (RS-485): 24 AWG, 120 ohm impedance, stranded
twisted pair with shield, 4000 (1,219 m) maximum
•
Mechanical:
-
Dimension: 4.75 x 2.75 x 1.25 in. (121 x 70 x 32 mm)
-
Weight: 3.5 oz. (100 g) nominal
•
Environmental:
-
Temperature: -10 to +70°C (14 to 158°F) operating, -40 to
+85
C (-40 to 185°F) storage
-
Humidity: 10% at 93°C (199°F) non-condensing operating, 10 to
95% at 85°C (185°F) non-condensing storage
•
Certifications:
FCC Part 15
FCC compliance: This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications.
ETL 294, s319
UL294, UL1076
C-Tick N22193
CE marking
RoHS
Environmental class: Indoor dry
WEEE
European Union directives: 2002/96/EC (WEEE directive): Products
marked with this symbol cannot be disposed of as unsorted municipal waste
in the European Union. For proper recycling, return this product to your
local supplier upon the purchase of equivalent new equipment, or dispose of
it at designated collection points. For more information see:
www.recyclethis.info.
UL Listed Installations
For UL installations, the following must be observed:
•
All field wiring terminals are suitable for single wire only.
•
Use 22 AWG minimum for wiring of RS-485, Input I1, and reader
data.
•
Do not use Input I2 for UL installations; “Do not supervise for UL.”
•
RS-485, Clock & Data reader communications is “Not Evaluated by
UL” and therefore cannot be used in UL installations.
•
RS-485 4-wire is “Not Evaluated by UL” and therefore cannot be used
in UL installations.
•
The use of AC Strikes is “Not Evaluated by UL” and therefore cannot
be used in UL installations.
•
Reader power for UL installations: 300 mA maximum for an operating
temperature range of -10 to +49°C (14 to 120°F).
•
Environmental for UL installations:
-
Temperature: -10 to +49°C (14 to 120°F) operating
-
Humidity: 85+/-5% at 30+/-2°C (86°F)
N22193