In case diagram A, the following table shows how each individual output signal acts:

Output signal

U

out

Description

OVERLOAD

< 0.2 V

The transducer head is saturated due to excessive primary current

+

U

C

The transducer head is not saturated

High 

I

P

< 0.2 V The primary current is higher than 105 % of nominal full-scale output

+

U

C

The primary current is lower than 105 % of nominal full-scale output

ACTIVE

< 0.2 V

The primary current is higher than approximately 1 % of nominal full-scale output

+

U

C

The primary current is lower than approximately 1 % of nominal full-scale output

STATUS

< 0.2 V When the unit status is OK (Normal operation)

+

U

C

When the unit status is not OK (Supply fault, over-temperature conditions and Current 

overloads or No detected head)

In case diagram B, the following table shows how each individual output signal acts:

Output signal

U

out

Description

OVERLOAD

+

U

C

The transducer head is saturated due to excessive primary current

< 0.2 V The transducer head is not saturated

High 

I

P

+

U

C

The primary current is higher than 105 % of nominal full-scale output

< 0.2 V The primary current is lower than 105 % of nominal full-scale output

ACTIVE

+

U

C

The primary current is higher than approximately 1 % of nominal full-scale output

< 0.2 V

The primary current is lower than approximately 1 % of nominal full-scale output

STATUS

+

U

C

When the unit status is OK (Normal operation)

< 0.2 V When the unit status is not OK (Supply fault, over-temperature conditions and Current 

overloads or No detected head)

The power supply v

U

C

 must be between 4 V and 60 V DC and the resistor value must be chosen between a minimum 

value 

R

min

 and a maximum value 

R

max

 calculated by using the following equations:

Some recommended standard values of 

R

 are given in the following table:

Power supply v

U

C

R

min

 (kΩ)

R

max

 (kΩ)

R

 Standards values ± 5 %

5 V

1.5

3

1.8 kΩ or 2.2 kΩ

12 V

3.5

7

4.7 kΩ or 6.8 kΩ

24 V

7

14

10 kΩ or 12 kΩ

Absolute maximum ratings

Parameter

Symbol

Specification

Unit

Power supply voltage

+

U

C

60

V

Maximum Collector-Emitter Voltage, Off-state

U

C E off max

60

V

Maximum reverse Collector-Emitter Voltage, Off-state

U

C E off max

5

V

Maximum Collector-Emitter Current, On-state

I

C E ON max

10

mA

Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the status/interlock signal outputs.

R

min

 (k

Ω

Ω

)

 

=

 

+

U

C

U

C

 

3

1.7

.4

  

and   

R

(k )

 

=

 

+

 

 

 

max

Содержание ITZ 2000-SBPR FLEX ULTRASTAB

Страница 1: ...lock port on 9 pin D sub male output connector Secondary current monitoring on BNC connector 4 mm banana sockets for secondary current output Full featured indicator panel Advantages Very high accurac...

Страница 2: ...ce required cleaning by dry compressed air is authorized This transducer is a build in device whose hazardous live parts must be inaccessible after installation This transducer must be mounted in a su...

Страница 3: ...degree 2 Rated insulation RMS voltage reinforced insulation UNm V 1250 IEC 61010 1 conditions over voltage cat III pollution degree 2 RMS voltage for AC insulation test 50 60 Hz 1 min Ud kV 10 8 Impu...

Страница 4: ...230 V RMS PC W VA 48 104 Average Peak RMS noise current 0 10 Hz 4 Ino ppm 0 1 RMS noise current 0 10 kHz 4 2 RMS noise current 0 100 kHz 4 60 Re injected RMS noise on primary bus bar 0 100 kHz V 10 Te...

Страница 5: ...o improve them LEM International SA Route du Nant d Avril 152 1217 Meyrin www lem com ITZ 2000 SBPR FLEX ULTRASTAB Typical power consumption 0 10 20 30 40 50 60 2500 2000 1500 1000 500 0 500 1000 1500...

Страница 6: ...lit when the transducer head saturates due to excessive primary current 600 A 24000 A yellow LED These LEDs are lit when a transducer head with the corresponding full scale range is connected to the r...

Страница 7: ...Status Interlock signal outputs 9 pin D Sub male UNC 4 40 screw lock 8 Option A B These positions are for future expansion or customization not used 2 8 3 1 7 6 5 4 LEM International SA Route du Nant...

Страница 8: ...esent on the port each having two dedicated floating pins in the SUBD9 Male connector Collector C and Emitter E Status Interlock port wiring Depending on how each signal is wired it can be Active Low...

Страница 9: ...sducer head is not saturated High IP UC The primary current is higher than 105 of nominal full scale output 0 2 V The primary current is lower than 105 of nominal full scale output ACTIVE UC The prima...

Страница 10: ...ed off When the rack electronics temperature cools to approximately 60 C the measuring circuit is automatically re enabled and the status LED is again lit Over current protection Electrical specificat...

Страница 11: ...ansducer head description Connect the transducer head to the electronics rack using the supplied transducer head cable and mount the programming plug in the 25 pin D Sub connector on the transducer he...

Страница 12: ...gh Out 6 Ground 7 US Low Sense 8 US Low Out 9 Current out 10 Current out 11 Current out 12 US High Sense 13 US High Out 14 US Low Sense 15 US Low Out Connect both pins 1 and 9 pins 2 and 10 pins 3 and...

Страница 13: ...mount ITZ FLEX ULTRASTAB electronics Transducer head European Schuko CEE 7 7 and US Japanese mains cables 2 m each with three pole IEC C13 female connector Short plug for 4 mm banana terminals and 15...

Страница 14: ...nt d Avril 152 1217 Meyrin www lem com ITZ 2000 SBPR FLEX ULTRASTAB Optional Calibration can be separately ordered as per the table hereafter Calibration with certificate in ISO 17025 certificated lab...

Страница 15: ...odifications on its transducers in order to improve them LEM International SA Route du Nant d Avril 152 1217 Meyrin www lem com ITZ 2000 SBPR FLEX ULTRASTAB Dimensions Rack electronics in mm general t...

Отзывы: