12. Commissioning your UNIROOF ST
The hot air welder should be used only in the open or in a well-ventilated area.
Never use the hot air welder in explosive or readily inflammable surroundings and maintain
sufficient distance from combustible materials or explosive gases at all times!
Read the material safety data sheet of the manufacturer of the material and follow that compa-
ny's instructions. Be careful not to burn the material during the welding process.
Use the device only on a horizontal (roof slope up to 30°) and fireproof support
In addition, comply with national statutory requirements regarding occupational safety (securing
safety of personnel or devices)!
Anti-fall protection when working on areas where there is a danger of falling.
When welding on roof parapet (parapet, eaves), the hot air welder on the carrying handle
(5) must be secured to a stop fixture with horizontal guides (e.g. rail or rope safety sys-
tems) as protection against falling.
With respect to the safety chain, care must be taken to ensure that all of the safety elements
(carabiner hooks, ropes) have a minimum load-carrying capacity of 7 kN in every anticipatable
direction. For the suspension of the machine, it is mandatory to use clasp carabiners (Twist-Lock
or screw-types). All safety chain connections must be installed and checked correctly in accor-
dance with manufacturer's specifications.
12.1 Work environment and safety