Version 2.1
09/2010
NOVOLAS Basic AT
Service and Troubleshooting
53
7.3
Laser Module Faults
Error
Cause
Measures
No aiming beam and no
or low weld laser
Broken fiber optic cable
Damaged laser module
Replace fiber optic cable
No weld laser but
aiming beam ok
Interlock circuit not closed
Interlock circuit not powered
No gate or trigger signal
Wrong current setting
Fault on current supply
Check interlock wiring
Check interlock wiring
Check for active gate or trigger
signal
Check current setting
Replace laser module
Weak laser power
Dirty optics
Fiber optic not tightly connected to
Laser module or optical housing.
Damaged laser module
Check optics and clean if
necessary.
Check fiber optic connector on
laser module and optical housing.
Replace laser module
7.4
Optics fault
Error
Cause
Measures
Bad aiming beam or
bad welding result
Dirt on Optics
Broken fiber cable
Clean Optics
Replace fiber cable
No aiming beam
but welding ok
Aiming beam inactive or defect
Check the configuration of
Register 900.
Check Input X14 “Aiming Laser Off”
No aiming beam
and no welding
Broken fiber cable
Replace fiber cable