NOVOLAS Basic AT
Operation
45
2
TEMP_2: Error Temperature 2
4
TEMP_3: Error Temperature 3
8
TEMP_4: Error Temperature 4
16
CONTROLTEMP: Temperature Error
in Laser diode
32
CURRENT LIMIT: Current error in
laser diode.
Check configuration. Take note of
the max current
128
CURRENTSOURCE: Common error
in current source
256
CURRENTSOURCE_VERSION:
wrong version of current source.
512
INTERLOCK: Common error in
interlock testing.
Restart. Replace module if
necessary (bei Leister service)
1024
LASERVOLTMAX: Laser voltage
exceeded maximum
Restart. Replace module if
necessary (bei Leister service)
2048
LASERVOLTMIN: Laser voltage
dropped below minimum
Restart. Replace module if
necessary (bei Leister service)
4096
SAFETY: Common error in safety
module.
Restart. Replace module if
necessary (bei Leister service)
8192
CUSTOMERIO LINK: Ethernet
communication with CustomerIO
failed
16384 OPTICINTERFACE_LINK: Ethernet
communication with OpticInterface
(pyrometer) failed
Module
interlock error
when using an air
cooled laser
module
(corresponds to
the messages as
provided in register
120, since it refers
to the same laser
module)
32786 ILOPENEDWHENLASERON: The
interlock was opened when the laser
was on
0
NO_ERR: No error.
1
ERR_SAFETY: Common error in
safety interlock
9911
LineBeam
Returns a value
describing an
interlock error
when using a
Linebeam
2
ILOPENEDWHENLASERON: Safety
interlock has been opened while
laser was on.