14
1
6
1
3
2
4
5
Device Description
8
7
Technical Data
1
Cable gland for mains connection
2
Air-inlet nozzle ø 60 or ø 90
3
Potentiometer for power setting
4
Assembly foot
5
Housing
6
Heating element pipe with protective tube
7
Cable gland for control connection
4 – 20 mA or 0 – 10 V
8
Cable gland for alarm contact
9
Potentiometer / Interface switch
Down: Potentiometer
Up: Interface
10
Interface
11
Alarm contact
3
2
1
4
5
2
1
11
9
10
Type
BASIC
SYSTEM
Voltage V~
3 × 400
3 × 480
3 × 230 3 × 400 3 × 400
Frequency Hz
50 / 60
50 / 60
Power kW
32
28
11 32
Minimum air volume l/min.
3800
2200
1100 3100
Maximum temperature °C
650
650
Ambient temperature °C
<60
< 60
Max. inlet air temperature °C
<100
< 50
Emission level L
pA
(dB)
<70
< 70
Weight kg
13.5
13.5
Dimensions mm
447 × 312 × 306
447 × 312 × 306
Conformity mark
2
2
Safety standard
Type of certification
Protection class I
1
1
The right to make technical changes is reserved