Ultra, Fault Finder on Ultra Advanced
95
11.4
Locate Faults
Known cable route
After the locator is homed, the locator will display signal strength and direction if sufficient
signal is present. If no signal is detected, detector will display
----
in center of screen.
1. Move 3 m (10’) down the cable route and ensuring that no services are below insert
fault probe again.
2. After arrows point in the opposite direction, insert detector a few meters (feet) back
down the cable.
3. Repeat step 2 moving smaller distances until arrow changes direction after only a few
millimeters (inches) of movement.
4. Rotate fault probe 90° and repeat location process until arrow switches direction after
a small movement. Fault is directly between probes.