GKL12 and GKL14
If you own one of these charging devices we
recommend:
- to use the battery charger GKL12 for charging the
battery insert (2-pole charging plug) of the total
station and for charging the GEB70 compact battery.
- to use the battery charger GKL14 for charging the
GEB71 universal battery.
Before you use new batteries for the first time, charge
them for 20 to 24 hours. This also applies to batteries
that have not been used for several months. NiCd
batteries reach full capacity after two or three normal
cycles each of a 14-hour charge followed by a full
discharge
If battery performance drops noticeably, run one or two
full cycles, i.e. charge for 14 hours and allow to
discharge until the instrument displays 'Battery low'.
Leave flat batteries to charge for fourteen hours. If you
do not know a battery’s state of charge, also leave it to
charge for fourteen hours.
Set the battery charger’s voltage selector to your AC
mains voltage, 115V or 230V. Plug in the charger to the
mains. The green indicator lamp should light. If it does
not light, there is a power cut or the mains cable or
charger is faulty.
Connect the battery to the charger. The red charging
indicator should light. If it does not, the battery is not
charging, i.e. the battery cable is faulty or the battery
fuse has blown and should be replaced. On the GKL12,
you may not have started the timer or it may have
stopped at the end of the charging period.