© Leica
TC605/TC805/TC905/L-1.1.1en
111
Communication TC605/TC805/TC905/L and PC/Datalogger
For more detail information of command and data
structures refer to the handbook "Leica Instruments On-
Line" which is available from your Leica representative.
Set orientation
A new orientation direction can be transmitted at any
time provided that the instrument is in the measuring
display mode.
Command structure:
(_ = space char.)
Hz
PUT/21...2+12345678_CRLF
Set station coordinates
Station coordinates can be transmitted from an external
data recorder via RS232 interface at any time without
having to reset the instrument. However, the instrument
must be in the highest level (measuring mode).
Command structure:
(_ = space char.)
Point number (PtNr)
PUT/11....+12345678_CRLF
Easting (Eo)
PUT/84...0+12345678_CRLF
Northing (No)
PUT/85...0+12345678_CRLF
Height (Ho)
PUT/86...0+12345678_CRLF
Instrument height (hi) PUT/88...0+12345678_CRLF
Set a point number
Command structure:
(_ = space char.)
PUT/11....+12345678_CRLF