background image

35

Rugby 200-3.2.1en

Safety Directions

Although the laser meets the strict 
regulations and standards which are in 
force in this connection, Leica 
Geosystems cannot completely 
exclude the possibility that the laser 
unit may be disturbed by very intense 
electromagnetic radiation, e.g. near 
radio transmitters, walkie-talkies, 
diesel generators, power cables.

Check the plausibility of results 
obtained under these conditions.

FCC Statement (applicable in 
the U.S.)

WARNING:

This equipment has been tested 

and found to comply with the limits for 
a Class B digital device, pursuant to 
part 15 of the FCC rules.

These limits are designed to provide 
reasonable protection against harmful 
interference in a residential 
installation.

This equipment generates, uses and 
can radiate frequency energy and, if 
not installed and used in accordance 
with the instructions, may cause 
harmful interference to radio 
communications. However, there is no 
guarantee that interference will not 
occur in a particular installation. If this 
equipment does cause harmful 
interference to radio or television 
reception, which can be determined by 
turning the equipment off and on, the 
user is encouraged to try to correct the 
interference by one or more of the 
following measures:

Increase the separation between 
the equipment and the receiver.

Consult the dealer or an 
experienced radio/TV technician for 
help.

Reorient or relocate the receiving 
antenna.

Connect the equipment into an 
outlet on a circuit different from that 
to which the receiver is connected.

WARNING:

Changes or modifications not 

expressly approved by Leica 
Geosystems could void the user's 
authority to operate the equipment.

This device complies with Part 15 of 
the FCC Rules. Operation is subject to 
the following conditions:  (1) This 
device may not cause harmful 
interference, and (2) this device must 
accept any interference received, 
including interference that may 
cause undesired operation.      

This device complies with Part 15 of  
the FCC Rules. Operation is subject to  
the following conditions:  (1) This  
device may not cause harmful  
interference, and (2) this device must  
accept any interference received,  
including interference that may  
cause undesired operation.      

Содержание Rugby 200

Страница 1: ...Rugby 200 User Manual Version 3 2 English...

Страница 2: ...sult in death or serious injury CAUTION Indicates a potentially hazardous situation or an unintended use which if not avoided may result in minor or moderate injury and or appreciable material financi...

Страница 3: ...own Calibration 19 Adjusting Laydown Calibration 19 Troubleshooting 20 Care and Transport 22 Transport 22 Storage 22 Cleaning and Drying Windows 22 Technical Data 23 Rugby 200 23 IR Remote Control 731...

Страница 4: ...manual contains operating and set up procedures for common applications Its purpose is to describe the features of the Rugby 200 and how it operates This manual is not intended to describe specific ap...

Страница 5: ...attery pack 8 Battery Assembly Located in the base of the laser Remove the locking ring to replace the alkaline batteries 9 Manual Mode Indicator Flashes rapidly 5 Hz to indicate manual with cross axi...

Страница 6: ...is self leveling The Manual Mode Indicator will flash rapidly 5 Hz when in this mode Press the Auto Manual Button a second time to enter full manual mode The Manual Mode Indicator will flash slowly 1...

Страница 7: ...scanning Pressing the button will move the head in small increments Pressing and holding the button move the head more quickly 6 Beam Down Button Positions the beam directly below the aperture for la...

Страница 8: ...line or slope Pressing the button will move the head in small increments Pressing and holding the button move the head more quickly Rugby200 4 Head up Rugby200 5 Head right Rugby200 6 Head down Rugby...

Страница 9: ...ng H I Alert The Rugby has moved Calibration Mode In Calibration Mode the Low Battery and Manual Mode Indicators will blink alternately In the first axis the Low Battery will blink at 5 Hz the Manual...

Страница 10: ...Out of Temperature Range If the unit is set up and the environment is out of the specified operating temperature range all three LED s will turn on at the same time The operating temperature range for...

Страница 11: ...switch 5 to turn the H I Alert on and off 3 Beam Down Function With the unit on press and hold the off on switch 4 then press the down arrow 6 switch to turn the beam down function on and off 4 Off On...

Страница 12: ...ck of the bracket for using the Rugby 200 in the laydown position mounted to a tripod The Ceiling Grid Target Allows the user to visually detect the rotating beam throughout the jobsite The ceiling gr...

Страница 13: ...the AC adapter into the appropriate wall outlet The NiMH Battery Pack can also be charged separately from the laser Low Battery Indication There is a low battery warning indicator on the switch panel...

Страница 14: ...t take a charge check the following Check the AC input and DC output of the charger unit Check that the Rugby has a rechargeable pack installed Check charger cables for wear or damage Refer to your Ru...

Страница 15: ...ic mode 4 Allow the Rugby to self level 5 Adjust the Rugby so the rotating beam is at the desired distance below the grid height Loosen the adjustment knob on the side of the bracket and slide the Rug...

Страница 16: ...General Construction The rotating beam creates a level plane of laser light over the entire jobsite that is used as a reference Used together with a Rod Eye handheld receiver or a machine mounted 360...

Страница 17: ...unit to self level completely approximately one minute after the unit begins to rotate and then mark the position of the beam position 1 3 Rotate the Rugby 180 allow it to self level and mark the oppo...

Страница 18: ...ill turn off for one half second to indicate that a key has been pressed 6 Rotate the laser 180 and check the opposite side of Axis One position 2 7 Reposition the Rugby so that the handle is now poin...

Страница 19: ...ting Laydown Calibration 1 With the Rugby still in laydown position enter calibration mode the same as described for upright cali bration steps 1 3 2 Have the rotating beam scan the plumb line then us...

Страница 20: ...l the laser has completed self leveling In manual mode the Level Warning Indicator will flash at 5 Hz and the Rugby will not self level The Rugby 200 has stopped working and the H I LED indicator is f...

Страница 21: ...low battery LED is blinking The battery charge is low or dead See symption 1 above The Rugby is rotating at seven rps to indicate to the Rod Eye Pro that the laser has reached a low battery condition...

Страница 22: ...original packaging case and cardboard box or its equivalent to protect it against shock and vibration After transport or after long periods of storage inspect the field adjustment parameters given in...

Страница 23: ...R Article nr 732001 Serial nr 200 Class II 2 Operating Temperature 4 to 122 F 20 to 50 C Storage Temperature 40 to 158 F 40 to 70 C Battery Life 50 hours with alkaline 30 hours with NiMH Batteries Fou...

Страница 24: ...ntinuous applications use of the Product Knockdown Warranty In addition to the standard Leica Geosystems 24 month warranty the internal self leveling system of the Rugby 200 is covered regardless of f...

Страница 25: ...by rechargeable NiMH optional or Alkaline batteries The unit can be used with an infrared remote A plumb beam is generated by the unit for purposes of alignment Scan modes from 10 to 180 can be gener...

Страница 26: ...the laser unit are responsible for developing implementing and communicating safety concepts for their products and are also responsible for the effectiveness of those safety concepts in combination...

Страница 27: ...surements if the product is defective or if it has been dropped or has been misused or modified Precautions Periodically carry out test measurements and perform the field adjustments indicated in the...

Страница 28: ...position the instrument on the tripod baseplate without securely tightening the central fixing screw If the screw is loosened always remove the instrument immediately from the tripod WARNING If the p...

Страница 29: ...ll other functions and features are the same on each model Review the information below for the unit you have purchased The products are clearly identified by article number serial number and safety l...

Страница 30: ...ts used on construction sites and outdoors surveying alignment leveling a Only qualified and trained persons should be assigned to install adjust and operate the laser equipment b Proof of qualificati...

Страница 31: ...void direct eye exposure The accessible emission limit is within five times the accessible emission limits of Class 2 in the wavelength range from 400 nm to 700 nm WARNING Direct intrabeam viewing is...

Страница 32: ...er beam should be termi nated at the end of its useful path and should in all cases be termi nated if the hazardous beam path extends beyond the limit hazard distance of the area in which the presence...

Страница 33: ...man Service Code of Federal Regulations Class 2 II laser products Do not stare into the beam or direct it unnecessarily at other persons Eye protection is normally afforded by aversion responses inclu...

Страница 34: ...eosystems cannot completely exclude the possibility that other equipment may be disturbed CAUTION There is a risk that disturbances may be caused in other equipment if the laser unit is used in conjun...

Страница 35: ...tion If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interfe...

Страница 36: ...which meets the International Standards of Quality Management and Quality Systems ISO standard 9001 and Environmental Management Systems ISO standard 14001 732987 3 2 1en Printed in Switzerland Copyr...

Отзывы: