15
Rugby 200-3.2.1en
Applications
Applications
Installing Ceiling Grid
1 Attach the Rugby 200 to the Wall-
mount Bracket. The side with the
control buttons should be facing
outward. Tighten the bottom
locking knob until the Rugby is
secured to the bracket.
2 After mounting the first strip of
ceiling trim at the desired height,
attach the Wallmount Bracket to the
trim. Tighten the locking knob on
the top of the bracket until the
secured.
3 Press the Off/On Power Button to
turn on the Rugby. The Rugby will
always turn on in automatic mode.
4 Allow the Rugby to self-level.
5 Adjust the Rugby so the rotating
beam is at the desired distance
below the grid height. Loosen the
adjustment knob on the side of the
bracket and slide the Rugby up or
down. When the Rugby is at the
desired height on the scale,
retighten the adjustment knob.
6 Install the ceiling grid. With the
Rugby attached to the first piece of
trim and adjusted to the desired
height, work can begin. Attach the
magnetic target to the ceiling grid
and adjust the height of the grid
until the rotating beam is striking
the center of the target.
Use the Remote Control to slow the
rotation of the beam or to change to
scan mode and rotate the scanning
beam to the area being worked.
Rugby200-13 ceiling.eps
Содержание Rugby 200
Страница 1: ...Rugby 200 User Manual Version 3 2 English...