Accuracy refers to measurements to standard prisms.
Distance
measuring
mode
Standard
deviation
ISO 17123-4,
standard prism
Standard
deviation
ISO 17123-4,
tape
Measurement
time, typical [s]
Single Auto
1 mm + 1.5 ppm
3 mm + 2 ppm
2.4
Continuous
with lock
3 mm + 1.5 ppm
3 mm + 2 ppm
< 0.15
Beam interruptions, severe heat shimmer and moving objects within the beam
path can result in deviations of the specified accuracy.
The display resolution is 0.1 mm.
Type
Description
Principle
Phase measurement
Type
Coaxial, visible red laser
Carrier wave
658 nm
Measuring system
System Analyzer Basis 100–150 MHz
7.3
Distance Measurement without Reflectors
(Non-Prism mode)
Pinpoint R500 (without reflector)
Kodak Gray Card
Range D
Range E
Range F
[m]
[ft]
[m]
[ft]
[m]
[ft]
White side
90% reflective
250
820
500
1640
>500
>1640
Grey side
18% reflective
100
330
150
490
>200
>820
Range of measurement:
1.5 m to 500 m
Display unambiguous:
up to 500 m
Range
Description
D
Object in strong sunlight, severe heat shimmer
E
Object in shade, or overcast
F
Underground, night and twilight
Standard
measuring
ISO17123-4
Measure time,
typical [s]
Measure time,
maximum [s]
0m - 500m
2 mm + 2 ppm
3 - 6
15
Beam interruptions, severe heat shimmer and moving objects within the beam
path can result in deviations of the specified accuracy.
Tracking
measuring*
Standard deviation
Measure time, typical [s]
Tracking
5 mm + 3 ppm
0.25
Accuracy
Characteristics
Range
Atmospheric condi-
tions
Accuracy
46