background image

Leica Microsystems Inc.

Educational and Analytical Division

PO Box 123

Buffalo, New York USA 14240 0123

Tel 716 686 3000

Fax 716 686 3085

www.leica-microsystems.com

ISO-9001 Certified

©2000 Leica Microsystems Inc., Buffalo NY USA  ISO 9001  Printed in USA  13596060-100  Rev

. B  2/00

Due to a policy of continuous development, we reserve the right 
to change specifications without notice.

Aufgrund der fortlaufenden Neuentwicklungen behalten wir uns das
Recht vor, jederzeit ohne Vorankündigung Änderungen vornehmen zu
können.

En raison de notre politique de développement continu, nous nous
réservons le droit de modifier les spécifications sans préavis.

En vista de nuestra política de desarrollo continuo, nos reservamos 
el derecho de modificar las especificaciones sin previo aviso.

Содержание DM E

Страница 1: ...Leica DM E Koehler Illumination Instruction Manual ...

Страница 2: ...r Phase Turret condensers 2 Lens in holder 3 Mounting bolts 4 Koehler field diaphragm 5 Mounting ring 6 Aspherical lens 7 DM E light port 8 Condenser centering screws 2 9 2 5mm Allen wrench 10 Blue daylight and green filters included with Koehler Illumination Kit ...

Страница 3: ...inate stray light from entering the field of view with the use of a field diaphragm This is done by a combination of precision optics condenser adjustment and adjusting a field diaphragm so only the field of view is illuminated The proper adjustment for Koehler illumination is described after the installation instructions Check that you have the following components in your Koehler illumination Ki...

Страница 4: ... port window Save this for possible later use 11 Remove the power cord from the back of the instrument 12 Carefully tip the microscope on its back and remove the 4 screws holding the rubber feet 13 While holding the base in place with one hand tip the microscope back onto its base to its normal operating position 14 Carefully lift the microscope off of its base 15 Looking into the light port you w...

Страница 5: ...k plate with the stand s groove 27 Tip the microscope on its back holding the base with one hand 28 Remount the four rubber feet with screws and tip the microscope back onto the base returning it to it s normal operating position 29 Reconnect the power cord into the back of the microscope and rettach the cord wrap lock if necessary 30 Position the field diaphragm with protective window onto the li...

Страница 6: ...wing through the microscope close the field diaphragm which you have just installed using the field diaphragm lever You will see the iris leaves imaged within the field of view 10 Using the condenser adjustment focusing knob focus the condenser until the leaves of the field diaphragm are in sharp focus 11 Center the image of the field diaphragm by turning the condenser centering screws This is bes...

Страница 7: ...6 ...

Страница 8: ...olicy of continuous development we reserve the right to change specifications without notice Aufgrund der fortlaufenden Neuentwicklungen behalten wir uns das Recht vor jederzeit ohne Vorankündigung Änderungen vornehmen zu können En raison de notre politique de développement continu nous nous réservons le droit de modifier les spécifications sans préavis En vista de nuestra política de desarrollo c...