background image

3

2.0 Installation

1 Unplug the microscope and remove the eyepieces.

2 Raise the stage to the highest position using the microscope coarse focus control knob.

3 Lower the condenser to the lowest position using the condenser focus control knob.

4 Using the Allen wrench which came with the microscope, remove the two alignment set 

screws which are holding the condenser in place. Save these alignment set screws for 

possible later use.

5 Remove the condenser from the condenser bracket.

6 Raise the condenser bracket to the highest position using the condenser focus.

7 Remove the blue daylight filter from the underside of the condenser. Save this filter for 

possible later use.

8 Insert the lens holder from the Koehler kit into the underside of the condenser.

9 Using the 2.5mm wrench provided with the Koehler kit, remove the mounting bolts holding 

down the light port window to the microscope stand.

10 Remove the light port window. Save this for possible later use.

11 Remove the power cord from the back of the instrument.

12 Carefully tip the microscope on its back and remove the 4 screws holding the rubber feet.

13 While holding the base in place with one hand, tip the microscope back onto its base to its

normal operating position.

14 Carefully lift the microscope off of its base.

15 Looking into the light port, you will see a lens held into a circular fixture with a mounting 

ring. At the six o’clock position of the circular fixture (closest to you) there is a notch.

16 Insert the ball of the 2.5mm wrench into the notch and pull up on the mounting ring. 

The mounting ring should pop out of the light port.

17 Hold a tissue over the light port and turn the base upside down. The lens will fall into the 

tissue. Save this for possible later use.

18 While the base is upside down, open the lamp door.

19 Take the aspherical lens which is provided with the Koehler kit and insert it into the light 

port so that the diffused, spherical side is flush with the bottom of the light port. You will be

able to see this through the opened lamp door. 

Содержание DM E

Страница 1: ...Leica DM E Koehler Illumination Instruction Manual ...

Страница 2: ...r Phase Turret condensers 2 Lens in holder 3 Mounting bolts 4 Koehler field diaphragm 5 Mounting ring 6 Aspherical lens 7 DM E light port 8 Condenser centering screws 2 9 2 5mm Allen wrench 10 Blue daylight and green filters included with Koehler Illumination Kit ...

Страница 3: ...inate stray light from entering the field of view with the use of a field diaphragm This is done by a combination of precision optics condenser adjustment and adjusting a field diaphragm so only the field of view is illuminated The proper adjustment for Koehler illumination is described after the installation instructions Check that you have the following components in your Koehler illumination Ki...

Страница 4: ... port window Save this for possible later use 11 Remove the power cord from the back of the instrument 12 Carefully tip the microscope on its back and remove the 4 screws holding the rubber feet 13 While holding the base in place with one hand tip the microscope back onto its base to its normal operating position 14 Carefully lift the microscope off of its base 15 Looking into the light port you w...

Страница 5: ...k plate with the stand s groove 27 Tip the microscope on its back holding the base with one hand 28 Remount the four rubber feet with screws and tip the microscope back onto the base returning it to it s normal operating position 29 Reconnect the power cord into the back of the microscope and rettach the cord wrap lock if necessary 30 Position the field diaphragm with protective window onto the li...

Страница 6: ...wing through the microscope close the field diaphragm which you have just installed using the field diaphragm lever You will see the iris leaves imaged within the field of view 10 Using the condenser adjustment focusing knob focus the condenser until the leaves of the field diaphragm are in sharp focus 11 Center the image of the field diaphragm by turning the condenser centering screws This is bes...

Страница 7: ...6 ...

Страница 8: ...olicy of continuous development we reserve the right to change specifications without notice Aufgrund der fortlaufenden Neuentwicklungen behalten wir uns das Recht vor jederzeit ohne Vorankündigung Änderungen vornehmen zu können En raison de notre politique de développement continu nous nous réservons le droit de modifier les spécifications sans préavis En vista de nuestra política de desarrollo c...

Отзывы: