background image

7

Measuring

Leica DISTO™ D210XT 776114

EN

D

N

S

FIN

DK

SLO

TR

GR

ROK

RUS

SK

CZ

H

PL

EST

LT

LV

BG

RO

Measuring

Single Distance Measurement

1x briefly: the laser is activated.

1x briefly: a distance measurement is taken. 

The result is displayed immediately.

Continuous measurement

Distances can be staked out with this function

1x long: a "beep" is sounded. A continuous 
measurement is started.

1x briefly: the continuous measurement is 
stopped. 

The last measured value is displayed in the summary 
line.

Minimum-/Maximum-Measuring

This function enables determining the minimum or 
maximum distance from a specific measuring point, 
e.g. the determination of room diagonals (maximum 
value) or horizontal distance (minimum value).
Switching on continuous measurement (see above). 
The corresponding maximum and minimum values are 
displayed.

Functions

Addition / Subtraction

Distance Measurement.

1x briefly: the next measurement is added to 
the previous one.

1x briefly: the next measurement is subtracted 
from the previous one.

Repeat this procedure for as many times as required. 
The result is displayed in the summary row, the previ-
ously measured value is displayed in intermediate line 
2, the value to be added in intermediate line 1.

1x briefly: the last step is cancelled.

Area function

1x briefly: The 

 symbol is displayed.

1x briefly: takes first distance measurement 
(e.g. length)

1x briefly: takes second distance measurement 
(e.g. width)

The result of the area measurement is displayed in 
the summary row, the individually measured values 
are displayed in intermediate lines 1 and 2.
A long press on the 

 key displays the perimeter 

.

Содержание DISTO D210XT

Страница 1: ...cial and environmental damage Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner Intended Use Permitted uses...

Страница 2: ...ies The manufacturers of non Leica accessories for the Leica DISTO are responsible for developing imple menting and communicating safety concepts for their products They are also responsible for the e...

Страница 3: ...CE key 7 HISTORICAL MEMORY UNITS key 8 CLEAR OFF key Display 1 Laser ON 2 Reference front rear end piece tripod 3 min max display 4 Battery status 5 Area volume 6 Info symbol 7 Pythagoras 8 Historical...

Страница 4: ...attery compart ment seals Operation Measuring Conditions Range Range is limited to 70 m At night or dusk and if the target is in shadow the measuring range without target plate is increased Use a targ...

Страница 5: ...such a way that in case of an erroneous measurement malfunction of the device or power failure due to installed safety measures e g safety limit switch it is assured that no damage will occur Switchin...

Страница 6: ...snaps in push the stop bracket with a little force to the right side the stop bracket can now be completely unfolded The device automatically recognises the measurement position and adjusts the follo...

Страница 7: ...imum value Switching on continuous measurement see above The corresponding maximum and minimum values are displayed Functions Addition Subtraction Distance Measurement 1x briefly the next measurement...

Страница 8: ...me appears in the summary line the last three measured values appear in interme diate lines 1 2 3 Press the button for longer to display additional room information such as circumference ceiling floor...

Страница 9: ...is pressed for along time while measuring a distance maximum or minimum contin uous measuring is activated Indirect measurement determining a distance using 3 auxilliary measurements 2x briefly the s...

Страница 10: ...e either displayed with or Error The following errors can be corrected Cause Correction 204 Calculation error Repeat procedure 252 Temperature too high Let device cool down 253 Temperature too low War...

Страница 11: ...en tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful inter ference...

Страница 12: ...product is a Class 2 Laser Product in accordance with IEC60825 1 2007 Radiation safety of laser products Class 2 Laser Products Do not stare into the beam or direct it unnecessarily at other persons...

Страница 13: ...ste Care for the environment and take them to the collection points provided in accordance with national or local regulations The product must not be disposed with household waste Dispose of the produ...

Страница 14: ...6114 EN D N S FIN DK SLO TR GR ROK RUS SK CZ H PL EST LT LV BG RO http www leica geosystems com treatment or received from your Leica Geosystems dealer All right reserved for changes drawings descript...

Страница 15: ...uality Systems ISO standard 9001 and Environmental Management Systems ISO standard 14001 Total Quality Management Our commitment to total customer satisfaction Ask your local Leica Geosystems agent fo...

Отзывы: