15
3.7 Performing the slide reference run
The slide motor and control panel are adjusted to match each other
at the factory. The setting can be lost in the course of time or when
replacing the control panel.
Switch off the machine.
Press and hold the button for switching between speed
and slide and the + button to switch the machine on.
The slide performs its reference run.
Approx. 240 is displayed as the upper value and approx. 40 as the lower
value; in the second line the message
OK
is displayed.
Switch machine off at ON/OFF switch so that the values are stored.
If a slide reference run cannot be performed, the following message
flashes on the display:
slide not calib
.
Check the mechanical clearance of the slide, the cable and the
connectors. Then perform the reference run again.