background image

Tynetec, a business unit of Legrand Electric Ltd 

Cowley Road, Blyth Riverside Business Park, Blyth, Northumberland, NE24 5TF. 

Tel: +44 (0) 1670 352371    www.tynetec.co.uk 

Trusted Technology 

Caring for People 

869MHz 
Door Open Alarm

 

 
 

 

 
_________________________________________________________________________

 

________________________________________________________________ 

 
 

 
 

 

 

  Doc No. FM0826 V1.06 Page 1   

 

 

 

 

 

 

 

 

 

 

 

 

Fixed trigger device 

 

Used to support the care of dementia patients 

 

Compatible with Reach IP, Advent XT2 & Carer Response 

 

Complies with BS EN 50134-2:2017 

 

Integrated left and right-side reed switches 

 

Surface magnetic door contact 

 

Red alarm transmit LED indicator  

 

Green alarm received LED indicator 

 

2 No. AAA Alkaline batteries 

 

Low battery warning 

 

Operating Temperature: +5

o

C to +40

o

C  

 

Telecare Transceiver: 869.2125MHz Class 1.5 

 

Digital Heartbeat 

 

Weight: 55 grams 

 

Dimensions: 85mm x 34mm x 24mm (HxWxD) 

 

Product Code: ZXT830

 

 

 

The door alarm can be used to raise a door open alarm 
when a door is opened.     

 

The Reach IP can be setup with an active time span (i.e. 
start time and end time) when the door alarm will be 
active. Door open alarms will only be reported if the door 
is opened within this pre-set time period. 

 

Note: with this type of door alarm, it is not possible to set 
an active time span on the Advent XT2 or Carer Response. 
With these products a door open alarm will be reported 
whenever the door is opened.   

 
 
 

Positioning

 

The door alarm can be mounted on the door frame and 
the magnet on the door, or vice-versa. The magnet can be 
placed on either side of the door alarm. The distance 
between the door alarm and the magnet must not exceed 
10mm when the door is closed. If the door is made from 
metal the magnet may need to be closer.  

 

Alarm Condition

 

When a monitored door is opened, it transmits an alarm 
and the LED will illuminate red for 4 seconds. When the 
alarm is acknowledged by the Reach IP or XT2 system the 
LED will illuminate green for 2 seconds 

 it does not go 

green when used with a Carer Response. A new alarm will 
not be triggered until the door has been closed and 
opened again. 
 

Low Battery Condition

 

A low battery condition will be reported automatically to 
the Alarm Receiving Centre (ARC) or the local Manager. 
The batteries should be replaced as soon as possible within 
30 days.  
 

Out of Range Notification (Reach IP)

 

The Reach IP can monitor all radio peripheral devices to 
determine whether they have been damaged or removed 
from an installation. Should the Reach IP be unable to 

detect a device’s heartbeat it will automatically generate a 
“radio out of range” notification. Firstly, investigate if 
there’s a genuine reason for the alert, if not, arrange for 

the peripheral device to be replaced immediately.  

The “Radio out of range

 

timer” can be set from 30 hours to 

99999 hours in Pulse CMP. “Radio supervision” can be 

disabled by unchecking the tick box associated with each 
peripheral device in Pulse CMP.

 

 

Maintenance

 

Test the door alarm once every month. 
Clean with a damp cloth, do not use solvents or cleaners 
on the door alarm. 
 

Disposal

 

Waste electrical products should not be disposed 
of with normal household waste. The door alarm 
is ideally suited for disposal within the waste 
electronic and electrical equipment (WEEE) 

recycling scheme. Please recycle where facilities exist.  
Check with your local authority or contact your supplier for 
recycling/disposal advice. 

 