11
Description
LEARN ke
y
Control
ke
y
s
I
d
entification No.
Comm
u
nication me
d
ia
RF => Ra
d
io Freq
u
enc
y
12
Operation
The radio mobile dimmable plug controls the load connected to its socket using the ON, OFF, + or -, keys or following
a command received from a Leader product that it was linked to during the learn phase
(1)
of a scenario
(2)
.
It is then the Actor of a scenario and can take part in a maximum of 16 scenarios.
Setting the light level of the ON key (excluding learning procedure):
- Set the level using the + and - keys,
- Press the + and ON keys at the same time, for 5 seconds,
- The load will extinguish and light up again at the ON level.
The ON level is now saved.
To save a light level during learn phase, stage 2 of Scenario learn phase becomes:
(1) Learn phase: Operation of associating products so that they can be controlled simultaneously from a central point.
This association is carried out by applying the
scenario learning
procedure on page 13.
(2) Scenario: Corresponds to the set of products (actors) that are associated with a control key.
���
���
Press the + or -
control keys to set
the desired light level
Press the control
key that is to be
linked with the leader
Press
LEARN