Safety instructions

This product should be installed preferably by a qualified 

electrician.

Incorrect installation and use can entail risk ofelectric shock 

or fire.

Before carrying out the installation,read the instructions and 

take account of the product’s specific mounting location.

Do not open up the device. All Legrand products must be 

opened and repaired only by personnel trained and appro-ved 

by Legrand.

Any unauthorised opening or repair completely cancels all 

liabilities and the rights to replacement and guarantees.

Only use Legrand brand accessories.

Factory set configuration

When first powering up, pressing on the ON or OFF keys

controls all the remote dimmers cabled into the bus.
This facility is provided in order to check the correct func-tio-

ning of all the lights.
A double press on the LEARN

(1)

 key cancels this general

control function.

(1)

Programming or learning key.

Protection by electronic device:

- In the event of an overload and with temperatures higher 

than the max. operating temp, the product automatically 

regulates the power by reducing the lighting.

- In the event of a short-circuit or a very high overload, the 

remote dimmer switches off. When the fault has been rec-

tified, the product returns to normal functioning.

Содержание 0 036 71

Страница 1: ...s Conforms to IEC 60669 2 1 0 C to 45 C Do not mix loads oftype and 110 V 500 W 500 W 500 VA 500 VA 230 V 1000 W 1000 W 1000 VA 1000 VA Incandescent lamp Halogen lamp ELV Halogen lamp with ferroma gne...

Страница 2: ...ights red ifprotected Ifthe type oflighting load is changed press simultaneously for 10 secs on the ON O buttons on the front The colour of the LED green orange has no bearing on the correct functioni...

Страница 3: ...arantees Only use Legrand brand accessories Factory set configuration When first powering up pressing on the ON or OFF keys controls all the remote dimmers cabled into the bus This facility is provide...

Страница 4: ...ic transformers must be charged to over 60 of their nominal power Take into account the efficiency ofthe ferromagnetic transformers when calculating the acceptable power example transformer for a 50Wl...

Страница 5: ...29 Cabling with single push button Single push button Single pushbutton 100 m max L Short circuit the product...

Страница 6: ...30 Local functioning Short press on the ON key Short press on the OFF key Long press on the ON key Long press on the OFF key Action L...

Страница 7: ...31 Local functioning continued 66 33 Short press on the 1 key Short press on the 2 key Long press on the 1 key Long press on the 2 key Action L...

Страница 8: ...of key 1 is then recorded Required level Required level After switch offthe load will relight at the required level Required level Required level After switch off the load will relight at the require...

Страница 9: ...vel memory To activate level memory simultaneous long press on buttons OFF and 1 To deactivate level memory simultaneous long press on buttons ON and 2 After switch off the load will light up again at...

Страница 10: ...34 Push button operation Action L L Action Short press Short press Long press Long press...

Страница 11: ...35 Short press Long press Short press Push button operation continued Action L L Action L...

Страница 12: ...dimmer transmitter Press the LEARN key Press the LEARN key and keep it pressed for 10 seconds The indicator light blinks slowly The indicator light blinks rapidly The indicator light flashes Action Th...

Отзывы: