Any ventilation fitted must comply with BS 5871 part 2 and BS 5440 part 2. Ventilation fitted under, or within
immediate vicinity of the appliance must not be used as it may adversely effect performance of the ODS sys-
tem. The appliance MUST NOT be installed in a bedroom, bathroom or any sleeping area. For Republic of
Ireland, see relevant rules in force. The appliance should not be installed within 500mm of any air vent.
U
UN
NPPA
AC
CK
KIIN
NG
G TTH
HEE A
APPPPLLIIA
AN
NC
CEE
Remove the straps and the top lid of the outer packaging, remove any instructions or fixing kits.
Read ALL these instructions before continuing to unpack or install this appliance.
Lift off the remaining packaging components and remove the contents of the box.
Check that the components supplied correlate with the component checklist. Please dispose of all the packag-
ing materials at your local recycling centre.
C
CO
OM
MPPO
ON
NEEN
NTT C
CH
HEEC
CK
KLLIISSTT
Q
QU
UA
AN
NTTIITTYY
D
DEESSC
CR
RIIPPTTIIO
ON
N
1
Firebox and burner assembly
1
Set of manufacturers instructions
1
Decorative frame assembly
1
Screw and wall plug pack
1
Rubber grommet
1
Fitting template
G
GA
ASS SSU
UPPPPLLY
Y R
RO
OU
UTTEESS
There are four possible entry points for the gas sup-
ply pipework to enter the appliance firebox. These
entry points are ‘knock out’ type holes.
Non-concealed gas connections may be made using
the entry points at either end of the firebox or the
one in the bottom of the firebox. A concealed gas
connection may be made using the knock out hole
in the centre back of the firebox. Select the most
appropriate entry point and knock out the relevant
hole
No more than 1.5m of 8mm diameter pipe must be
used to avoid unnecessary pressure drops.
If a concealed gas connection is to be made, the supply pipe should always be sleeved through walls and floors
using the shortest possible route.
For concealed supply pipe routing, pipes must (where possible) be vertical and providing there is sufficient wall
thickness available, they should be placed in pipe chases. Horizontal pipe runs should be avoided. Prior to chas-
ing a solid wall, an inspection should be made to note the proximity of any cables/sockets outlets which may
already be buried.
Pipes must be secured using suitable clips and protected against corrosion. Ideally factory finished protected
pipework and fittings should be used. Joints should be kept to a minimum and compression fittings must not be
used. The pipework installation must be tested for soundness before any protection is applied and/or the
pipework and fittings are buried.