Turn on and test the gas supply up to the fire for any leaks, in accordance with the current edition of BS6891.

O

OPPEER

RA

ATTIIN

NG

G TTH

HEE A

APPPPLLIIA

AN

NC

CEE

The pilot is visible behind the left hand side of the burner.

The control knob is located on the lower right hand side of the outer
case. It is of a spherical design and is marked as shown in the diagram
to the right;

Push in and turn the control knob to the SPARK position, and hold
there for a few seconds. Continue turning anti-clockwise through the
spark click to the PILOT light position, ensuring the pilot has lit. If not,
return the knob clockwise, and repeat.

When the pilot lights after the spark, keep the knob depressed for
approximately ten seconds.Now release the knob and the pilot
should stay alight. If the pilot is extinguished during use, wait three
minutes before repeating the ignition procedure. 

To achieve the HIGH setting, push the control knob in slightly and
continue turning anti-clockwise to the high position. The main burner should light after a few seconds.  To
decrease the setting to LOW, turn the control knob clockwise to the low setting.

To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and return to the pilot
position and release. To turn the fire OFF, keep the knob pressed in, return to the off position and release.

SSPPA

AR

RK

K FFA

AIILLU

UR

REE

The gap between the spark electrode and the pilot should be 3 - 5mm to produce a good spark.  There should
be no need to adjust this.  If under any circumstances the piezo electric spark fails, the pilot cannot be lit man-
ually.

SSEETTTTIIN

NG

G PPR

REESSSSU

UR

REE

The pressure test point is located on the left hand side of the appliance, on the main burner pipe, next to the
brass restrictor/connector. Release the setting pressure test point screw, and attach a U gauge. Light the fire on
the HIGH setting.

To commission the appliance, the burner pressure must be in accordance with the figures stated in the data sec-
tion of these instructions. 

The fire is factory set to achieve these pressures and any
significant variation could indicate a supply problem. If
the pressure is too high, the gas supply meter may be set
incorrectly.  This should be checked with the fire running
and if necessary reset by the gas supplier.

If the burner pressure is too low, then check the inlet
pressure with the appliance running.  If this is less than
approximately 20mbar it will need to be reset by the gas
supplier. If the setting pressure is too low, but the meter
pressure is acceptable, then a problem in the supply
pipework is to be suspected.  

This will be dirt and debris, kinked or inadequate size
pipes, restriction in a fitting, shut off elbow not fully open or solder flashing across a joint. Identify the cause of
the restriction and rectify. Switch the fire off, disconnect the U gauge and refit the test nipple screw. Light the
fire and check for gas soundness. 

In the event that the burner pressure is not in accordance with the figures stated in the data section of these
instructions, the appliance must not be commissioned, and the manufacturer should be contacted for guidance.

88..33

88..00

88..11

88..22

‘OFF’ position

‘SPARK’ position

‘LOW’ position

‘HIGH’ position

Содержание ECO 500

Страница 1: ...the end user when the installation is complete This is an official requirement and is the responsibility of the fitter of this appliance Having installed the appliance the installer should take the necessary steps to ensure that the user fully understands how to operate the appliance and is also made aware of the fire s basic cleaning and maintenance requirements ...

Страница 2: ...e circulation of air and ensure the correct operation of the fire This volume may include adjacent spaces but these spaces must not be separated by a door In order to convert from cubic feet ft3 to cubic metres m3 divide the room volume in ft3 by 35 3 This appliance is intended as a secondary source of heat only and should not be used in a room without some form of background heating present The a...

Страница 3: ...ex type vents featuring internal baffles It should be noted that heaters create warm air currents These currents move heat to wall surfaces next to the heater Installing the heater next to vinyl or cloth wall coverings or operating the heater where impurities in the air such as tobacco smoke exist may discolour walls Consult ALL instructions before installation and use of this appliance This appli...

Страница 4: ...p pa ar rt t o of f t th he e a ap pp pl li ia an nc ce e i in nt to o t th he e w wa al ll l This Appliance may be installed in any room in a home however there are exceptions and the appliance may not be used in the following rooms Bedrooms or areas which are mainly used for sleeping Bathrooms or areas where large amounts of steam are likely to be generated Installation in living rooms is common...

Страница 5: ...mstances should any electrical equipment e g plasma screen TV sets etc be positioned on the wall above the appliance The appliance is designed to be wall mounted alone and not in conjunction with any type of combustible fire surround No combustible shelves should be positioned on the wall above the appli ance It should be established that any mirrors or picture frames etc to be positioned on the w...

Страница 6: ... UP PP PL LY Y R RO OU UT TE ES S There are four possible entry points for the gas sup ply pipework to enter the appliance firebox These entry points are knock out type holes Non concealed gas connections may be made using the entry points at either end of the firebox or the one in the bottom of the firebox A concealed gas connection may be made using the knock out hole in the centre back of the f...

Страница 7: ...ecommended to check the horizontal alignment of the appliance with a spirit level as small adjustments can still be made if neces sary When this has been checked tighten all four fixing screws fully To access the upper fixing screws insert a screwdriver either through the round holes in the front of the outlet grille or alterna tively for easier access the outlet grille may be removed and the fixi...

Страница 8: ...re should be no need to adjust this If under any circumstances the piezo electric spark fails the pilot cannot be lit man ually S SE ET TT TI IN NG G P PR RE ES SS SU UR RE E The pressure test point is located on the left hand side of the appliance on the main burner pipe next to the brass restrictor connector Release the setting pressure test point screw and attach a U gauge Light the fire on the...

Страница 9: ...tting pressures 15 Check safe operation of the appliance For specific servicing instructions see relevant sections 7 7 9 9 0 0 1 10 0 0 0 8 8 4 4 Monet frame shown as example B BR RI IE EF FI IN NG G T TH HE E C CU US ST TO OM ME ER R All instructions must be handed to the user for safekeeping Show the customer how to light and control the fire After commissioning the appliance the customer should...

Страница 10: ...ft brush and blow through Check the aeration holes are free of any dirt or lint Clean thoroughly internally the connection can be removed from the base of the pilot unit using two span ners to make cleaning easier Do not damage or try to dismantle the pilot injector The unit is factory set and the only check necessary is to ensure the spark gap is correct See specifications for gas setting N NE EV...

Страница 11: ... metal work reset gap correctly Blocked pilot clean out internally P Pi il lo ot t l li ig gh ht ts s b bu ut t t th he en n g go oe es s o ou ut t Severe restriction in gas supply clear obstruction Faulty thermocouple replace pilot unit Blocked pilot clean out Blocked lint gauze clean Hold control knob in for longer Check control knob does not foul indicator plate If the pilot will not stay lit t...

Страница 12: ...all surfaces as working surfaces with the exception of the control knob control panel and the openable control panel Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper low temperature surrounds etc may discolour if fitted too close to the fire See relevant section for fur ther details on clearances to combustibles No combustible materials...

Страница 13: ...viding it is relatively flat and does not interfere with the various vent holes in the back panel of the appliance The wall must be structurally sound and constructed from a material capable of withstanding moderate heat Finished plaster conventional wall paper and dry lined plasterboard are examples of suitable materials Materials such as flock blown vinyl and embossed paper which are sensitive t...

Страница 14: ... to the SPARK position and hold there for a few seconds Continue turning anti clockwise through the spark click to the PILOT light position ensuring the pilot has lit If not return the knob clockwise and repeat When the pilot lights after the spark keep the knob depressed for approximately ten seconds Now release the knob and the pilot should stay alight If the pilot is extinguished during use wai...

Страница 15: ...ng safely and that there is no exces sive build up of soot The frequency of service will depend on usage but MUST be carried out at least once annually Servicing must be carried out by a competent person such as a CORGI registered installer The Installation instructions carry full servicing details for the use of the installer L LI IS ST T O OF F S SP PA AR RE E P PA AR RT TS S P PA AR RT T N NO O...

Страница 16: ...Unit 200 Glenfield Park Site 1 Philips Road Blackburn Lancashire BB1 5PF Tel 01254 695244 Fax 01254 695255 Web www legend fires com Email info legend fires com Issue 3 25 07 06 ...

Отзывы: