SYSTEM OPTIONS
Power Save
This is a battery save feature that makes batteries last longer on a single charge.
Power Save Enable
Enables the Power Save Feature.
Save On Time
This is the amount of time that the receiver is on and looking for calls. This value is set
in milliseconds and the default is 400ms. Range is 50 to 2000ms.
Save Off Time
This is the amount of time that the receiver is off and not looking for a call. This value
is set in milliseconds and the default is 200ms. Range is 50 to 2000ms.
Save Delay Time
This is the amount of time that the radio will wait after a call has been received before
going back into power save mode. Range is .5 to 10 seconds.