15
seconds), select the function setting, choose output voltage setting interface, at the moment, the letters
“ECO” will flash.
②
Enter the ECO setting interface. Press and hold the function setting key
for more than half a
second(less than 2 seconds), then come to setting interface of ECO, at this time, th
e letters “ECO” will not
flash any more. The “ON” (or OFF) will flash. Press and hold the inquiring key (
,
)
for more than
half a second (less than 2 seconds) to determine whether the ECO function is used or not. If used, the
corresponding word is “ON”, if not, the word is “OFF”. It can be determined by yourself.
③
Confirm the ECO selecting interface. After selecting ON or OFF, press and hold the function setting
key
for more than half a second (less than 2 seconds). Now, the ECO setting function is completed
and the “ON” or “OFF” will light without flash.
④
Exit from the setting interface. Press and hold function setting key
for more than 2 seconds, exit from
the setting interface and return to main interface.
4.6.2 Input methods setting
①
Enter the setting interface. Press and hold the function setting key
for more than 2 seconds, then come
to setting interface, press and hold the inquiring key (
,
)
for more than half a second(less than 2
seconds), select the function setting, choose output voltage setting interface, at the moment, the letters
“IPP” will flash.
②
Enter the IPP setting interface. Press and hold the function setting key
for more than half a second(less
than 2 seconds), then come to setting interface of IPP, at this time, the letters “IPP” will not flash any more,
the numerical value next to the IPP will flash. Press and hold the inquiring key (
,
)
for more than
half a second (less than 2 seconds) to select the numerical value. There are two Input methods, the value
‘1’ means single phase input, the value ‘3’ means three phase input. The default input method is single
phase.
③
Confirm the IPP selecting interface. After selecting input method, press and hold the function setting
key
for more than half a second (less than 2 seconds). Now, the IPP setting function is completed and
Содержание 3106