Work Status Indicator Lights
37
controller to the
supplier for repair
0xdf
Overtime slave USB
interface communication.
1. Replace the USB
communication cable if
this error occurred
frequently.
2. Try on another PC if
the error can’t be
eliminated by following
the 1
st
step
3. Return the controller
to the supplier for
repair if the error can’t
be eliminated by
following the 2
nd
step
0xf1
Config file error. It is
possibly caused by
forgetting to download the
cfg file, or the cfg file
doesn’t match with the
firmware.
Re-download correct
configuration file
0xf2
Mismatched firmware file
(*.fmw) and hardware file
(*.hdw)
Re-download matching
fmw file and hdw file.
0x55
Speed-zero clamp signal is
effective.
Keep speed-zero clamp
input (IN3) on.
0xff
Servo out-of-step alarm
Examine the wiring of
servo motor drive and
controller to make all
connections right and
then restart the drive.
Caution
Please restart MPC6575 if any error occurred to resume to
the normal status. Then solve the problem according to the
above error codes descriptions.