WALD
LEENDERS
2019.
49.002.I.EN
Installation option 1&2
4. Determine the length of the double-walled inner flue
Use a telescopic, double-walled flue that can be adjusted to fit
- L= Length telescopic double-walled flue, excluding the connector
- X = Length mantel pipe Wald
- Y = Length of double-walled flue that protrudes from the ceiling
- L = X - Y - 65mm
5a. Double-walled connector
Install the connector for the double-walled flue
5b. Poujoulat connector (only for use with the Poujoulat Efficience)
Install the connector for the Poujoulat Efficience flue
6. Perparing the mantel pipe
Lay the mantel pipe horizontally. Insert the double-walled flue adjusted to length into the mantel pipe.
Bring the mantel pipe with the double-walled flue inot an upright position.