4.

 

Once  the  sensor  detects  a  water  leak,  the  LED  Indicator  flashes  and  the  alarm  beeps  once  per 

second. The alarm signal will be sent to the gateway once every 5 minutes. During the alarm status, 

the user can mute the buzzer by using the App. If the sensor still detects a water leak after 10 minutes, 

the detector will trigger the alarm again and another signal will be sent to the gateway and the user. 

The alarm will be canceled if the situation as below. 

 

Water leak is controlled/stopped 

 

User presses the mute status by using the app 

 

The button on the sensor itself is pressed 

 

Power is turned off 

Details about the alarm:

 there are four settings to select from in App.   

 

0: Buzzer muted, LED off 

 

1: Buzzer muted, LED flashes 

 

2: Buzzer on, LED off 

 

3: Buzzer on, LED flashes (Default setting) 

 

6. When the battery voltage low, the detector will send a low battery signal to the gateway. 

 

8.    Notes

 

1.

 

Replace the battery immediately when the low battery warning sounds to ensure the detector is 

working properly. 

2.

 

Do not store any items on the surface of detector, as this may affect the sensors. 

3.

 

Clean the surface with soft towel regularly. 

4.

 

In  the  unlikelihood  of  a  product  failure,  do  not  attempt  to  repair.  Please  contact  the  local 

distributor. 

 

 

Содержание 8B-SS-ZF-H0

Страница 1: ...ter Leak Sensor 2 1 Product Introduction 2 2 Product Profile 2 3 Specification 2 4 Features Capabilities 4 5 Installation Notice 4 6 Installation Guide 5 7 Product usage 5 8 Note 6 We build your succe...

Страница 2: ...ive immediate alerts if a leak or flooding occurs in your home such as in a basement near a water heater under an old pipe or in a bathroom Early alerts can help you prevent leaks from turning into fl...

Страница 3: ...Battery Power Source 3V AAA 2 Battery Life 5 years Communication Protocol Zigbee 3 0 Radio Frequency 2 4GHz Wireless Range 100ft 40m LOS Operational Temperature 0 40 Operating Humidity Up to 85 non c...

Страница 4: ...or has a low battery alarm to Zigbee Gateway Hub devices 4 Installation Notice 1 Install the detector in areas where there is a concern about possible water leaks such as bathrooms basements water hea...

Страница 5: ...key on the bottom cover for about 3 seconds then the LED signal light will start blinking quickly B Release the reset key and the sensor will be reset to factory settings and the LED signal light bli...

Страница 6: ...atus by using the app The button on the sensor itself is pressed Power is turned off Details about the alarm there are four settings to select from in App 0 Buzzer muted LED off 1 Buzzer muted LED fla...

Страница 7: ...een tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference...

Страница 8: ...de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique sub...

Отзывы: