background image

www.prolight.co.uk

Visio LP 600RGB LED Panel 

User Manual

2

Safety advice

WARNING

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL  
CAREFULLY BEFORE YOUR INITIAL START-UP!

•  Before your initial start-up, please make sure that there is no damage caused during transportation.
•  Should there be any damage, consult your dealer and do not use the equipment.
•  To maintain the equipment in good working condition and to ensure safe operation, it is necessary  

for the user to follow the safety instructions and warning notes written in this manual.

•  Please note that damages caused by user modifications to this equipment are not subject to warranty.

IMPORTANT:

The manufacturer will not accept liability for any resulting damages caused by the non-observance  
of this manual or any unauthorised modification to the equipment.

 
OPERATING DETERMINATIONS

If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and  
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. 
Do not endanger your own safety and the safety of others! 
Incorrect installation or use can cause serious damage to people and/or property.

•  This product is designed to be installed by a  

competent, qualified installation technician  
into commercial environments.

•  Never let the power cable come into contact with other 

cables. Handle the power cable and all mains voltage  
connections with particular caution!

•  Never remove warning or informative labels from the unit.
•  Do not open the equipment and do not modify the unit.
•  Do not connect this equipment to a dimmer pack.
•  Do not switch the equipment on and off in short intervals, 

as this will reduce the system’s life.

•  Only use the equipment indoors.
•  Do not expose to flammable sources, liquids or gases.
•  Always disconnect the power from the mains when  

equipment is not in use or before cleaning! Only handle 
the power-cable by the plug. Never pull out the plug by 
pulling the power-cable.

•  Make sure that the available voltage is 24V DC.
•  Make sure that the power cable is never crimped or  

damaged. Check the equipment and the power cable 
periodically. 
 

•  If the equipment is dropped or damaged, disconnect the 

mains power supply immediately and have a qualified 
engineer inspect the equipment before operating again.

•  If the equipment has been exposed to drastic  

temperature fluctuation (e.g. after transportation),  
do not connect power or switch it on immediately.  
The arising condensation might damage the equipment. 
Leave the equipment switched off until it has reached 
room temperature.

•  If your product fails to function correctly, stop use 

immediately. Pack the unit securely (preferably in the  
original packing material), and return it to your Pro Light 
dealer for service.

•  Only use fuses of same type and rating.
•  Repairs, servicing and power connection must only be  

carried out by a qualified technician. THIS UNIT CONTAINS 
NO USER SERVICEABLE PARTS.

•  This lighting fixture is for professional use only - it is 

not designed for or suitable for household use. The 
product must be installed by a qualified technician in 
accordance with local territory regulations. The safety of 
the installation is the responsibility of the installer. The 
fixture presents risks of severe injury or death due to fire 
hazards, electric shock and falls.

•  WARRANTY: One year from date of purchase.

CAUTION!

KEEP THIS EQUIPMENT 

AWAY FROM RAIN,  

MOISTURE AND LIQUIDS

CAUTION!  

TAKE CARE USING  

THIS EQUIPMENT!
HIGH VOLTAGE-RISK  

OF ELECTRIC SHOCK!!

Содержание Visio LP 600RGB

Страница 1: ...Order code LEDC250 Visio LP 600RGB LED Panel User Manual ...

Страница 2: ...uipment on and off in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available voltage is 24V DC Make sure th...

Страница 3: ...mm panel 180 degree wide angle output Seamless edge to edge colour mixing White metal frame supplied with four installation tab brackets Captive four core cable with bare ends 24V constant voltage control Power consumption 52W Visio LP 600RGB LED Panel Specifications Visio LP 600RGB LED Panel Power supply DC 24V Dimensions 600 x 600 x 10mm Weight 3 25kg Order code LEDC250 In the box 1 x unit 1 x u...

Страница 4: ...UILT IN MODE DMX OUT DC IN 6A MAX LOAD 6A MAX BLUE GREEN RED 12 24V Data Data GND GND 12 24V Data Data GND FTP3 DMX IN DMX ADDRESS DIMMER SETTINGS OUTPUT SWITCH 10 11 12 DMX MODE DIMMING MODE BUILT IN MODE DMX OUT DC IN 6A MAX LOAD 6A MAX BLUE GREEN RED 12 24V Data Data GND GND 12 24V Data Data GND FTP3 DMX IN DMX ADDRESS DIMMER SETTINGS OUTPUT SWITCH 10 11 12 DMX MODE DIMMING MODE BUILT IN MODE D...

Страница 5: ... accessories and product range additions please visit www prolight co uk Visio 160W 24V DC Power Supply Order code LEDC236 3 Panels max Visio 320W 24V Power Supply Order code LEDC237 6 Panels max Flexoled FTP3 RGB LED DMX Driver Order code FLEX27 2 Panels max Flexoled FTP3HP RGB LED DMX Driver Order code FLEX30 5 Panels max Visio FLEXICON DMX Controller Order code FLEX31 ...

Страница 6: ...t possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environment...

Страница 7: ...www prolight co uk Visio LP 600RGB LED Panel User Manual 7 ...

Страница 8: ...www prolight co uk Visio LP 600RGB LED Panel User Manual 8 ...

Отзывы: