Notice:

Be sure to follow the diagrams below when making your own cables. Do not connect the cables  
shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs  
outer casing. Grounding the shield could cause a short circuit and erratic behaviour.

Special note: 

Line termination:

When longer runs of cable are used,  
you may need to use a terminator on  
the last unit to avoid erratic behaviour.

Using a cable terminator will decrease  
the possibilities of erratic behaviour. 
(3-pin - Order ref: CABL9O, 5-pin - Order ref: CABL89)

5-pin XLR DMX connectors:

Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR fixtures 
may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 
3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion.

Termination reduces signal transmission 

problems and interferance. it is always 

advisable to connect a DMX terminal, 

(resistance 120 Ohm 1/4 W) between pin 2 

(DMX-) and pin 3 (DMX+) of the last fixture.

5-pin XLR (socket)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

Pin 4: N/C

Pin 5: N/C

3-pin XLR (socket)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

3-pin XLR (socket)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

5-pin XLR (socket)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

Pin 4: N/C

Pin 5: N/C

DMX setup

Содержание LEDJ71

Страница 1: ...Order codes LEDJ71 Black housing LEDJ71A White housing Slimline 3HEX12 Series 3 x 12W 6 in 1 colour LEDs RGBAWUV User Manual Optional IR remote Order ref LEDJ90F Convection cooled no fan ...

Страница 2: ...not open the equipment and do not modify the unit Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by th...

Страница 3: ...ield angle 35 1 2kHz refresh rate DMX channels 2 3 3 4 4 5 6 or 9 selectable Static colour colour change colour fade auto run sound active and master slave modes 0 100 dimming with variable strobe Bracket allows for multiple rigging and floor standing applications Rear control panel and rubber feet allow the panel to sit flat on the floor for uplighting 4 push button menu with LED display Side ent...

Страница 4: ...rth point 04 LED display 05 Function buttons 06 DMX input socket 07 DMX output socket 08 IEC power in socket 09 IEC power out socket 10 Fuse F1A 250V In the box 1 x fixture 1 x power cable 1 x user manual 08 10 09 03 07 06 ENTER DOWN MODE UP SLIMLINE 3HEX12 www prolight co uk POWER IN POWER OUT DMX OUT DMX IN 02 04 05 01 PUSH ...

Страница 5: ...ired DMX address Now press the ENTER button to choose one of the 2 3 3 4 4 5 6 or 9 DMX channel modes Use the UP and DOWN buttons and press the ENTER button to confirm the setting To exit out of any of the above options press the MODE button Channel Value Function 1 000 255 Master dimmer 0 100 2 000 255 colour macro 000 016 Red 017 033 Green 034 050 Blue 051 067 White 068 084 Amber 085 101 UV 102 ...

Страница 6: ...5 B 255 A 255 W 255 081 150 Colour jumping speed Slowest 081 changes every 8 secs Fastest 150 changes every 0 3 secs 151 220 Colour fading speed Slowest 151 changes every 8 secs Fastest 220 changes every 0 3 secs 221 255 Sound control mic sensitivity 3 channel mode 1 3 channel mode 2 Channel Value Function 1 000 255 Red 0 100 2 000 255 Green 0 100 3 000 255 Blue 0 100 4 000 255 White 0 100 Channel...

Страница 7: ...30 Amber 031 035 UV 036 040 Yellow R 255 G 200 A 255 041 045 Cyan G 255 B 255 046 050 Lavender R 170 B 210 051 055 Bright green G 255 A 180 056 060 Magenta R 255 B 90 UV 255 061 065 Turquoise G 255 B 180 UV 255 066 070 Orange R 200 A 200 071 075 Cool white R 70 G 190 B 255 A 200 076 080 Warm white R 230 G 255 B 255 A 255 W 255 081 150 Colour change speed Slowest 081 changes every 8 secs Fastest 15...

Страница 8: ...de press ENTER the LED display will change to FF using the UP and DOWN buttons to select any value from FF00 FF99 Value 00 99 00 low 99 high To exit out of any of the above options press the MODE button Colour change mode To access the colour change mode press ENTER until JU shows on the LED display To adjust the speed use the UP and DOWN buttons to select any value from JA00 JA99 To select the st...

Страница 9: ... options press the MODE button Colour preset mode To access the colour preset mode press ENTER until Cn shows on the LED display To adjust the colour use the UP and DOWN buttons to select any value from Cn01 Cn15 Press the ENTER button to confirm the setting To exit out of any of the above options press the MODE button Operating instructions Static colour mode C1 00 C1 99 R C2 00 C2 99 G C3 00 C3 ...

Страница 10: ... LEDs 10 Sets the LEDs colour use the and buttons to change the brightness 1 2 3 4 5 6 0 _ 7 8 9 AR D FL SL SP S S PR SA R G B W A UV BLACKOUT DIMMING FLASH SLAVE SPEED SET ADDR SELECT PROG SOUND ACTIVE AUTO RUN DMX MODE 03 01 04 10 02 05 07 08 06 09 To set the DMX address 245 Press the S button the red LEDs will come on you can now start to set the DMX address Now press the 2 button the green LED...

Страница 11: ... is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing ...

Страница 12: ...89 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interferance it is always ...

Страница 13: ...nt possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmen...

Страница 14: ...To keep up to date on the latest accessories and product range additions please visit www prolight co uk Optional Quad Case Holds 4 x fixtures Order code CASE95 Optional IR remote Order code LEDJ90F 1 2 3 4 5 6 0 _ 7 8 9 AR D FL SL SP S S PR SA R G B W A UV BLACKOUT DIMMING FLASH SLAVE SPEED SET ADDR SELECT PROG SOUND ACTIVE AUTO RUN DMX MODE ...

Страница 15: ...www prolight co uk Slimline 3HEX12 Series User Manual 15 ...

Страница 16: ...www prolight co uk Slimline 7HEX6 Series User Manual 16 ...

Отзывы: