background image

www.prolight.co.uk

Colour Blast 80

  

User Manual

2

Safety advice

WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL  
CAREFULLY BEFORE YOUR INITIAL START-UP!

•  Before your initial start-up, please make sure that there is no damage caused during transportation.
•  Should there be any damage, consult your dealer and do not use the equipment.
•  To maintain the equipment in good working condition and to ensure safe operation, it is necessary  

for the user to follow the safety instructions and warning notes written in this manual.

•  Please note that damages caused by user modifications to this equipment are not subject to warranty.

IMPORTANT:

The manufacturer will not accept liability for any resulting damages caused by the non-observance  
of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONS

If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and  
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. 
Do not endanger your own safety and the safety of others! 
Incorrect installation or use can cause serious damage to people and/or property.

CAUTION!

KEEP THIS EQUIPMENT 

AWAY FROM RAIN,  

MOISTURE AND LIQUIDS

CAUTION!  

TAKE CARE USING  

THIS EQUIPMENT!
HIGH VOLTAGE-RISK  

OF ELECTRIC SHOCK!!

•  Never let the power cable come into contact with other 

cables. Handle the power cable and all mains voltage  
connections with particular caution!

•  Never remove warning or informative labels from the unit.
•  Do not open the equipment and do not modify the unit.
•  Do not connect this equipment to a dimmer pack.
•  Do not switch the equipment on and off in short intervals, 

as this will reduce the system’s life.

•  Only use the equipment indoors.
•  Do not expose to flammable sources, liquids or gases.
•  Always disconnect the power from the mains when  

equipment is not in use or before cleaning! Only handle 
the power-cable by the plug. Never pull out the plug by 
pulling the power-cable.

•  Make sure that the available mains supply voltage is 

between 100~240V AC, 50/60Hz.

•  Make sure that the power cable is never crimped or  

damaged. Check the equipment and the power cable 
periodically.

•  If the equipment is dropped or damaged, disconnect the 

mains power supply immediately and have a qualified 
engineer inspect the equipment before operating again. 
 

•  If the equipment has been exposed to drastic  

temperature fluctuation (e.g. after transportation),  
do not connect power or switch it on immediately.  
The arising condensation might damage the equipment. 
Leave the equipment switched off until it has reached 
room temperature.

•  If your product fails to function correctly, stop use 

immediately. Pack the unit securely (preferably in the  
original packing material), and return it to your Pro Light 
dealer for service.

•  Only use fuses of same type and rating.
•  Repairs, servicing and power connection must only be  

carried out by a qualified technician. THIS UNIT CONTAINS 
NO USER SERVICEABLE PARTS.

•  This lighting fixture is for professional use only - it is 

not designed for or suitable for household use. The 
product must be installed by a qualified technician in 
accordance with local territory regulations. The safety of 
the installation is the responsibility of the installer. The 
fixture presents risks of severe injury or death due to fire 
hazards, electric shock and falls.

•  Warning! Risk Group 2 LED product according to 

EN 62471. Do not view the light output with optical 
instruments or any device that may concentrate the beam.

•  WARRANTY: One year from date of purchase.

Содержание Colour Blast 80

Страница 1: ...Order code LEDJ116 Colour Blast 80 User Manual...

Страница 2: ...n short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is...

Страница 3: ...nds High frequency dimming ensures smooth colour fades and a flicker free performance time after time Control features include DMX master slave and sound activation The sit flat cylindrical housing wi...

Страница 4: ...output 09 Fuse T3A 250V 10 Hanging bracket 11 Hanging bracket adjustable knob In the box 1 x fixture 1 x 25 beam reduction lens 1 x 40 beam reduction lens 1 x power cable 1 x user manual 03 POWER INPU...

Страница 5: ...L 0 0 S o 0 1 S o 1 6 S J 1 S J 8 Sound active mode sound sensitivity S o 0 1 C h 0 4 C h 0 2 d 0 0 1 d 5 1 2 C h 0 5 C h 0 6 d r 1 d r 4 DMX settings dimmer curves d 0 0 1 C h 0 7 C h 1 0 r 0 0 0 g 0...

Страница 6: ...any of the above options press the MENU button Operating instructions Channel Value Function 1 000 No function 001 255 Halogen emulation 1800K 3200K 2 000 255 Master dimmer 0 100 2 channel mode Chann...

Страница 7: ...mer 0 100 5 000 031 LED off 032 063 LED on 064 095 Strobe slow fast 096 127 LED on 128 159 Strobe pulse slow fast 160 191 LED on 192 223 Strobe random slow fast 224 255 LED on 6 000 255 Master dimmer...

Страница 8: ...ur Change 5 Colour Fade 5 Sound Active 5 080 095 Colour Change 6 Colour Fade 6 Sound Active 6 096 111 Colour Change 7 Colour Fade 7 Sound Active 7 112 127 Colour Change 8 Colour Fade 8 Sound Active 8...

Страница 9: ...214 090 001 000 065 068 Dark Amber CL17 22 255 059 001 000 069 072 Sunrise Red CL18 25 249 083 002 000 073 076 Light Pink CL19 35 180 200 075 255 077 080 Medium Pink CL20 36 223 180 063 205 081 084 P...

Страница 10: ...196 Pale Lavender CL49 136 225 196 054 000 197 200 Special Lavender CL50 137 199 197 074 000 201 204 Primary Green CL51 139 059 229 001 000 205 208 Bright Blue CL52 141 000 243 079 000 209 212 Apricot...

Страница 11: ...lash speed To exit out of any of the above options press the MENU button Sound active mode To access the sound active mode press the MENU button until the display shows So01 on the LED display Use the...

Страница 12: ...of the above options press the MENU button IR remote To access the IR remote setting press the MENU button until the display shows Iron on the LED display Use the UP and DOWN buttons to select either...

Страница 13: ...ress again and buttons to adjust the dimmer curve mode 06 Sets the DMX address press once followed by three numeric buttons to set the DMX address required 07 Activates the slave sound modes Press onc...

Страница 14: ...DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ens...

Страница 15: ...5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin...

Страница 16: ...sible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material r...

Отзывы: