4
LED is on when the programmable output is active
+5VDC (from Pin 14)
380
Ohms
Programmable Output Pin
380
Ohms
LED is off when programmable output is active
+5VDC (from Pin 14)
Programmable Output Pin
GND (from Pin 15)
Relay is on when programmable output is active
Programmable Output Pin
GND (from Pin 15)
Relay Coil
Coil current < 100mA
1N4001
or equiv.
External DC Voltage
Source (<40VDC)
INSTALLATION
DSP4/4 Audio Inputs
Each of the four DSP4/4 inputs is balanced. The drawing
shows a typical interface between an unbalanced line
level source and the DSP4/4, and a balanced line level
source and the DSP4/4.
DSP4/4 Audio Outputs
Each of the four DSP4/4 outputs is balanced. To use an output in the unbalanced line level mode, take the signal
from the “+” output connection and the output ground. Leave the “-” output floating.
DSP4/4 Programmable Inputs
The DSP4/4 has 13 programmable inputs which can control a variety of DSP4/4 parameters. Each input can re-
spond to either a contact closure or a continuous voltage. The diagram below shows common connections to the
programmable input pins.
Each programmable input is internally pulled up through a 100K resistor to +5V, so no external pull up resistors are
necessary. When using a continuous voltage with one of the programmable inputs, the Function of the program-
mable input must be set to either Analog In Control or Analog Out Control. See the Programmable I/O tab for setting
all programmable input parameters.
DSP4/4 Programmable Outputs
The DSP4/4 has 8 programmable outputs which can indicate the current state of a programmable input. Each
programmable output is the electrical equivalent of a contact closure to ground. When a programmable output is
active, it conducts current to ground. When the programmable output is inactive, no current flows to ground. The
maximum usable voltage for the programmable outputs is 40V, and they will safely conduct up to 100mA DC continu-
ous. The following diagram shows some typical uses for the programmable outputs:
It is permissible to run LEDs from the +5VDC pins on the programmable input connector, as long as the total LED
current for all LEDS on does not exceed 100mA. Similarly, 5V relay coils may also be run from the +5VDC pins on
the programmable input
connector, as long as the
total coil current for all
relays on does not exceed
100mA. Note that the
diagram shows an external
DC source powering the
relay coil. This will be
necessary if coil voltages
above 5V are needed.
Unbalanced Line Level Source
Input +
Input -
Gnd
Input +
Input -
Gnd
Balanced Line Level Source
Pot Connection for Analog Control of Gain
10K Linear Pot
CCW
CW
+5V
To Programmable Input Pin
Gnd
Contact Closure as Programmable Input
To Programmable Input Pin
Gnd
DC Voltage Source as Programmable Input
To Programmable Input Pin
0VDC (Off) to +5VDC (On)
Gnd