![Lechler 5TM Series Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/lechler/5tm-series/5tm-series_maintenance-instructions-manual_1866010044.webp)
4
4
Shaft Pos. 9
Insert shaft 5TC.000.1Y.11.00.0 (Pos. 9) into bushing 5TM.000.T7.09.00.0 (pos. 8). Thereby
the worm on the shaft should face upwards.
Impeller
Mount the impeller 5TC.000.1Y.05.00.0 (pos. 7) with the pocket facing to the shaft (pos. 9).
Position the pocket precisely on the 2 flats of the shaft.
In order to fix the impeller with the cylinder
screw, it is necessary to lock the impeller
with a round rod (e.g. made of brass or pla-
stic), as already done during disassembly.
Next, the cylinder screw
5TC.000.1C.02.FR.0 (pos. 15) with washer
5TC.000.1Y.19.00.0 (pos.16) can be
tightened (approx. 3 – 4 Nm).